INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PAR- TICULATE EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2 , ULC S627, ULC S628, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.

INSTALLATION AND OPERATION INSTRUCTIONS FOR

HI-TECH LISTED SOLID FUEL BURNING STOVES AND INSERTS

FREE STANDING MODELS INSERT MODELS

EPA 1100, 1100L, 1100C, 1150, 1400, 1400L & 1900

EPI 1101, 1401

WARNING:

Please read this entire manual before you install and use your new room heater. Failure to

follow instructions may result in property damage, bodily injury, or even death.

If this unit is not properly installed, a house fire may result.

FOR YOUR SAFETY

Follow the installation directions. This unit can be very hot when burning. Combustible mate- rials such as firewood, wet clothing, etc. placed too close can catch fire. Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the fireplace is hot. The chimney must be sound and free of cracks. Before installing your unit, contact the local building or fire authority and follow their guidelines.

The door must be kept closed during operation to prevent smoke, embers from entering the room. Burn wood directly on firebricks. Do not use a grate or elevate the fire. At least 14 square inches (90 sq.cm.) of outside air must be admitted to the room or directly to the unit through a 4 inch (10cm.) diameter pipe. This unit is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as com- pared to softwoods or to green or freshly cut hardwoods. Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc. Do not burn treated wood, coal, charcoal, coloured paper, cardboard, solvents or garbage which tend to produce more pollution than wood. Do not let the unit become hot enough for any part to glow red.

KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to achieve heat output rates that exceed design specifications can result in steel distortion and damage.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212fax(705)722-6031

www.napoleonfireplaces.com • ask@napoleon.on.ca

W415-0512 / B / 11.15.05

Image 1
Contents EPA 1100, 1100L, 1100C, 1150, 1400, 1400L EPI 1101 Table of Contents Conditions and Limitations Napoleon Wood Fireplace Presidents Lifetime Limited WarrantyCare of Glass General InformationPedestal Models only LEG Models onlyInstalling the Legs Stove InstallationStove Installation Alcove InstallationPedestal Models Outside AIR Mobile HomeAdding Chimney Sections Wall PASS-THROUGHPrior to Installation Hint for Installing Porcelain Enamel InsertsInstallation Into a Masonry Fireplace Fireplace InsertOptional Blower Installation Into a Factory Built FireplaceStove Models LEG Models onlyGround Stud Securing Wingnut TAB WiresFinishing Operation Fire Extinguishers / Smoke Detectors Achieving Proper DraftFuel Loading and Burn Cycle Flash FireMaintenance Door Removal 1100C only Wood Pile MaintenanceDOS DontsReplacement Parts ReplacementsBlower KIT Accessories31A Fireplace Service History W415-0512 / B W415-0512 / B