Napoleon Fireplaces GDI30 manual GAS Installation, Optional Wall Switch

Page 10

10

2.3GAS INSTALLATION

!WARNING

RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH

AS SPARKS OR OPEN FLAMES.

SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.

ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG.

VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.

Proceed once the vent installation is complete. Installation and servicing to be done by a qualified installer

Do not use open flame.

Move the appliance into position and secure.

If equipped with a flex connector the appliance is designed to accept a 1/2” gas supply. Without the connector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut off valve to turn off the gas supply to the appliance.

Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.

When flexing any gas line, support the gas valve so that the lines are not bent or kinked.

Check for gas leaks by brushing on a soap and water solution.

30.1

2.4OPTIONAL WALL SWITCH

For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The

recommended maximum lead length depends on wire size:

 

 

 

 

 

WIRE SIZE

MAX. LENGTH

1

 

 

 

 

14 gauge

100 feet

 

 

 

 

2

 

OL

N

F

16 gauge

60 feet

 

 

 

 

 

O

18 gauge

40 feet

 

 

 

 

 

 

 

 

IP

 

 

 

 

HI

O

F

 

 

 

 

 

TOL

 

 

 

3

 

 

 

 

 

P

 

 

Disconnect the existing wires from terminals 1 and 3 (from the

 

TOLI

 

 

 

 

 

 

ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.

50.1

W415-0806 / 06.28.09

Image 10
Contents GDI-30N Table of Contents Introduction Warranty Conditions and LimitationsDimensions Installation OverviewGeneral Instructions General Information Care of GlassInsert Levelling InstallationChimney Connection Exhaust GAS Installation Optional Wall SwitchFraming Minimum Mantel ClearancesDoor Glass Replacement Door Removal and InstallationFinishing Grate Installation LOG PlacementOptional Charcoal Embers Logo PlacementGlowing Embers Optional Blower Installation Front Blower Access CoverWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperation Lighting InstructionsPilot Burner Adjustment AdjustmentsVenturi Adjustment Flame Adjustment MaintenanceFlame Characteristics Replacements ComponentsTerminal Kits Accessories W415-0806 Trouble Shooting Symptom ProblemSymptom Problem Test Solution Do not Over TorqueService History Appliance Service History44.1

GDI30 specifications

Napoleon Fireplaces has long been recognized for its commitment to quality and innovation in the fireplace industry. One of its standout products is the GDI30, a gas insert that skillfully blends design, functionality, and efficiency. This model brings the allure of a traditional fireplace into modern homes, offering both aesthetic appeal and practical heating capabilities.

The GDI30 is designed with a powerful heat output of up to 30,000 BTUs, making it suitable for heating medium to large spaces. The unit employs advanced technology to deliver superior efficiency, boasting a 78% thermal efficiency rating. This percentage reflects the insert's ability to convert a significant portion of its gas input into usable heat, ensuring that homeowners benefit from effective warmth while minimizing fuel consumption.

One of the remarkable features of the GDI30 is its use of the patented “Penta” burner system. This technology creates a realistic flame pattern, enhancing the visual experience of the fireplace. The flames can be adjusted to suit the user's preferences, allowing for customized ambiance and comfort. Additionally, the unit is equipped with high-quality ceramic glass, which offers superior heat retention and ensures that the heat is radiated into the room effectively.

The GDI30 offers a range of design options, allowing homeowners to choose from various front styles, finishes, and decorative media like logs, rocks, or glass. This customization means that the unit can seamlessly integrate into any home aesthetic, whether contemporary or traditional. The sleek design and large viewing area provide a captivating focal point for living spaces.

Furthermore, the GDI30 is engineered for ease of use and maintenance. The electronic ignition system ensures reliable starts, while the optional remote control or wall switch allows for effortless operation. For added peace of mind, the insert is equipped with safety features, including a safety shut-off valve and backup manual controls.

In summary, the Napoleon GDI30 gas insert is an exemplary product that combines cutting-edge technology, elegant design, and efficient heating. With its powerful output, customizable options, and ease of use, it remains a popular choice for homeowners seeking to enhance their living spaces with a beautiful and functional fireplace.