GAS INSTALLATION

1.Move the stove into position. We recommend secur- ing the stove to the floor, in all cases. Levelling / securing kit GDSLL-KT may be used for this purpose.

2.Install rigid black pipe, 1/2" type-L copper tubing or, if local codes permit, a 3/8" flex connector and shutoff valve to the gas line and the fireplace gas valve. Seal and tighten securely. An adapter fitting is required between the gas valve and the copper tubing or flex connector.

DO NOT KINK FLEX CONNECTOR.

FIGURE 5

3.Check for gas leaks by brushing on a soap and water solution.

DO NOT USE OPEN FLAME.

7

4.For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a con- venient location. Route a 2 strand, solid core millivolt wire from the stove to the wall switch or millivolt thermostat. The recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14

gauge

100 feet

16

gauge

60 feet

18

gauge

40 feet

Attach the two leads to terminals 1 and 3 located on the

gas valve.

1

 

 

 

 

 

 

 

 

 

FIGURE 6

2

 

OL

N

F

 

 

 

O

F

 

 

 

 

 

O

 

 

 

HI

 

P

 

 

 

 

 

 

 

3

 

 

TOLI

 

 

P

 

 

 

 

 

TOLI

 

 

DO NOT CONNECT EITHER THE WALL SWITCH, THER- MOSTAT OR GAS VALVE TO ELECTRICITY (110 VOLTS).

It is not necessary to install a hearth extension with this fireplace system. Objects placed in front of the fireplace should be kept a minimum of 4 feet away from the front face.

FINISHING

FRONT CAST INSTALLATION

CAST FRONT

SECURING BOLTS

MESH

SECURING

BOLTS

FIGURE 7a

1.Place the cast front face down on a protective surface such as a carpet or blanket to avoid scratching the fin- ished surface. Attach the screen to the inside of the front using four bolts and washers.

TOP FIGURE7b

RETAINER

FRONT

FIGURE 7c

2.Lift the top casting off the unit.

3.Fit the securing bolts on the cast front into each of the respective retainer brackets (located at ei- ther side on the top). In- sert and tighten the se- curing screw from the bottom up (located at the lower center behind the cast front). This will hold the cast front in place. Replace the top casting.

4.To remove the front, repeat in reverse order.

SECURING

SCREW

W415-0204 / C / 10.02.01

Image 7
Contents Unvented Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information Mobile Home InstallationGeneral Instructions Shipping BracketCombustion and Ventilation AIR Provisions Location and ClearancesExample RoomFront Cast Installation GAS Installation#4#3 #2 LOG Placement InstructionsBlower Installation To Turn OFF GAS For Your Safety Read Before OperatingOperating Instructions Lighting InstructionsOxygen Depletion Sensor Pilot Cleaning MaintenanceVenturi Adjustment Accessories / Options Ordering Replacement PartsReplacement Parts Description Replacement PartsSymptom Problem Test Solution Trouble Shooting GuideCarboning occurs Wolf Steel Fireplace Service History W415-0204 / C