GAS INSTALLATION
1.Move the stove into position. We recommend secur- ing the stove to the floor, in all cases. Levelling / securing kit
2.Install rigid black pipe, 1/2"
DO NOT KINK FLEX CONNECTOR.
FIGURE 5
3.Check for gas leaks by brushing on a soap and water solution.
DO NOT USE OPEN FLAME.
7
4.For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a con- venient location. Route a 2 strand, solid core millivolt wire from the stove to the wall switch or millivolt thermostat. The recommended maximum lead length depends on wire size:
WIRE SIZE | MAX. LENGTH | |
14 | gauge | 100 feet |
16 | gauge | 60 feet |
18 | gauge | 40 feet |
Attach the two leads to terminals 1 and 3 located on the | |||||
gas valve. | 1 |
|
|
|
|
|
|
|
|
| |
FIGURE 6 | 2 |
| OL | N | F |
|
|
| O | F | |
|
|
|
|
| O |
|
|
| HI |
| P |
|
|
|
|
| |
|
| 3 |
|
| TOLI |
|
| P |
|
| |
|
|
| TOLI |
|
|
DO NOT CONNECT EITHER THE WALL SWITCH, THER- MOSTAT OR GAS VALVE TO ELECTRICITY (110 VOLTS).
It is not necessary to install a hearth extension with this fireplace system. Objects placed in front of the fireplace should be kept a minimum of 4 feet away from the front face.
FINISHING
FRONT CAST INSTALLATION
CAST FRONT
SECURING BOLTS
MESH
SECURING
BOLTS
FIGURE 7a
1.Place the cast front face down on a protective surface such as a carpet or blanket to avoid scratching the fin- ished surface. Attach the screen to the inside of the front using four bolts and washers.
TOP FIGURE7b
RETAINER
FRONT
FIGURE 7c
2.Lift the top casting off the unit.
3.Fit the securing bolts on the cast front into each of the respective retainer brackets (located at ei- ther side on the top). In- sert and tighten the se- curing screw from the bottom up (located at the lower center behind the cast front). This will hold the cast front in place. Replace the top casting.
4.To remove the front, repeat in reverse order.
SECURING
SCREW