Napoleon Fireplaces GDS26N, GDS26P Mobile Home Installation, GAS Installation, Conversion Kits

Page 19

FIGURE 30

SCREWS

BAFFLE PLATE

FIGURE 31

RESTRICTOR

PLATE

1.Remove the front and the door from the stove.

2.Remove the screws securing the baffle plate. Figure 31. Note: The baffle rests on two screws that are attached to the back of the firebox.

3.Using the screws supplied, attach the restrictor plate as show in Figure 31.

4.Replace the baffle.

MOBILE HOME INSTALLATION

This appliance is certified to be installed as an OEM (Origi- nal Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance.

This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The stove is equipped with two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installa- tions, the stove must be fastened in place. Use #10 hex head screws, inserted through the holes in the base to secure. Always turn off the pilot and the fuel suuply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the stove, ensure that the logs are positioned correctly.

This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

This stove is only for use with the type of gas indicated on the rating plate. This stove is not convertible for use with other gases, unless a certified kit is used.

Conversion Kits

The mobile home appliance is field convertible between Natural Gas (NG) and Propane (LP).

To convert from one gas to another consult your Napoleon® dealer/distributor.

19

GAS INSTALLATION

Proceed once the vent installation is complete.

1.Move the stove into position and secure to the floor through the 1/4" holes located at either side of the base.

2.The stove is designed to accept 3/8" gas supply line. The stove is equipped with a 3/8" manual shut-off valve and flexible connector. Do not kink flexible connector.

3.Connect the gas supply in accordance to local codes. In the absence thereof, install according to the National Installation Code.

4.When flexing any gas line, support the gas valve so that the lines are not bent or kinked.

5.Check for gas leaks by brushing on a soap and water solution.

DO NOT USE OPEN FLAME.

Purge all gas lines with the glass door of the stove re- moved. Assure that a continuous gas flow is at the burner before re-installing the door.

A

B

Manual

 

 

 

 

Shut-off Valve

Shown

in “OFF” position.

FIGURE 32

Supply pressure can be checked by turning screw (A) counter-clockwise until loosened and then placing pressure gauge tubing over the test point. Gauge should read 7” (minimum 4.5”) water column for natural gas or 13” (11” minimum) water column for propane. Check that main burner is operating on “HI”.

Manifold pressure can be checked the same as above using screw (B). Gauge should read 3.5” water column for natural gas or 10” water column for propane. Check that main burner is operating on “HI”.

AFTER TAKING PRESSURE READINGS, TIGHTEN SCREWS FIRMLY TO SEAL. DO NOT OVERTORQUE. LEAK TEST

W415-0607 / A / 01.18.08

Image 19
Contents GDS26N Table of Contents Napoleon GAS Stove Presidents Lifetime Limited Warranty Do not Remove General Instructions General InformationCare of Glass and Plated Parts For example in Massachusetts StateVenting Lengths and AIR Terminal Locations DimensionsVent Installations VentingPeriscope Termination Typical Vent InstallationsSpecial Vent Installations Rear Exit TOP ExitMinimum AIR Terminal Location Clearances Stove Vent Exit Rear Exit TOP Exit Venting Application Flow ChartDefinitions TOP Exit / Horizontal TerminationElbow Vent Length Values Since both formulas are met, this vent configuration is = H R + H O = 8 + 2.7 = 10.7 ft+ V T= 10.7 + 6 =16.7 T = 4.2 x 6 = 25.2 ftHR3 Rear Exit / Horizontal Termination3.5V T + V T+ V T 24.75 feet HT VT TOP or Rear Exit Vertical TerminationHR2 HT + VTVertical Through Existing Chimney InstallationRear Exit Conversion Not Fill this Space with ANY Type of Material Installation Wall and Ceiling ProtectionHorizontal Installation Vertical InstallationSealant #8x1/2FIGURE 25 Self Drilling Horizontal Venting InstallationStove Vent Connection #10 xRestricting Vertical Vents Vertical Venting InstallationGAS Installation Mobile Home InstallationConversion Kits 47 1/2 to ceiling from base of the unit Minimum Clearances to CombustiblesTo ceiling from base of the unit Lens Assembly Installation Blower InstallationNight Light Replacement Bulb ReplacementFinishing Glass Door Installation and RemovalLogo Placement Door Glass ReplacementLOG Placement Switch FunctionsMain Burner Switch Night Lighttm SwitchGauge Wiring DiagramRecommended maximum lead length depends on wire size Wire Size MAX. LengthTo Turn OFF GAS Operation / MaintenanceMaintenance Operating InstructionsVenturi Adjustment AdjustmentsPilot Injector and Orifice Replacement Flame Adjustment and CharacteristicsReplacements 31 34 Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History W415-0607 / a

GDS26P, GDS26N specifications

Napoleon Fireplaces has long been a leader in the home heating industry, known for their innovative designs and reliable performance. Among their impressive lineup, the GDS26N and GDS26P models stand out as exceptional choices for gas fireplaces, each offering a unique blend of style and functionality that can enhance any living space.

The GDS26N is designed for natural gas, while the GDS26P is tailored for propane, catering to the diverse preferences of homeowners. Both models feature a compact size, making them suitable for various room sizes, from cozy dens to spacious living rooms. The contemporary design and clean lines of these fireplaces integrate seamlessly with different decor styles, providing both aesthetic appeal and warmth.

One of the standout features of the GDS26N and GDS26P is Napoleon's advanced technology, which ensures efficient operation and exceptional heating capabilities. The fireplaces come equipped with a powerful heating output, providing ample warmth even in larger spaces. Additionally, they feature a high-efficiency rating, allowing users to enjoy significant energy savings while maintaining a comfortable environment.

Both models boast an array of customizable options, including different media choices like ceramic fibers, rocks, or logs, enabling homeowners to personalize the look of their fireplace to suit their taste. The large viewing glass provides a stunning flame presentation, enhancing the ambiance without compromising on safety. The glass is designed to remain cool to the touch, ensuring peace of mind for families with children or pets.

Furthermore, Napoleon incorporates advanced safety features in the GDS26N and GDS26P, including a safety screen and a built-in oxygen depletion sensor that automatically shuts off the appliance if oxygen levels drop too low. This attention to safety is a cornerstone of Napoleon’s philosophy, ensuring that users can enjoy their fireplace with confidence.