Vanguard Heating VMH3000TPA Operating Heater, For Your Safety Read Before Lighting

Page 14

®

PROPANE/LP GAS RESIDENTIAL HEATERS

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Figure 22).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 16 through 18. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15.

Ignitor Button

Control Knob

 

LO

 

PILOT

 

OFF

 

HI

IGNITOR

 

Figure 22 - Control Knob In The OFF Position

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a quali- fied service person or gas sup- plier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 23 - Pilot

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

For more information, visit www.desatech.com

14

107098

Image 14
Contents VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATER What to do if YOU Smell GASSafety Information Local CodesProduct Identification AssemblyProduct Features UnpackingLocate brass front trim in brass trim package Attaching Brass Front Trim to Front PanelAssembling and Attaching Brass Trim Unusually Tight Construction Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building AIR for Combustion and VentilationVentilation AIR Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Items Locating HeaterMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Securing Hearth Base to Floor Mounting Heater to Optional MantelMounting Heater to Optional Hearth Base Connecting to GAS Supply External Regulator with Vent Pointing DownChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternSafety interlock system has been trig TroubleshootingPilot assembly After ODS/pilot lights, keep controlMaintenance, Pane/LP companyGas odor even when control knob is in OFF TopCleaning and Maintenance Replacement PartsIllustrated Parts Breakdown VMH3000TPAParts List KEY VMH3000TPA Description QTYService Hints SpecificationsTechnical Service When Gas Pressure Is Too LowAccessories Warranty Information

VMH3000TPA specifications

The Vanguard Heating VMH3000TPA is a cutting-edge heating solution designed to provide efficient warmth to both residential and commercial spaces. This model combines advanced technology with robust construction to ensure reliable performance throughout the heating season.

One of the main features of the VMH3000TPA is its high-output heating capability. With a powerful performance of up to 3000 watts, it effectively heats large areas, making it an ideal choice for open floor plans and larger rooms. The unit is designed for effortless installation and can be easily mounted on walls or placed in various settings, providing flexible placement options.

Energy efficiency is a hallmark of the VMH3000TPA. It incorporates a smart thermostatic controller that allows users to set desired temperatures accurately and maintain them with minimal power consumption. This not only ensures comfort but also helps in reducing energy bills, making it an economically sound choice.

The VMH3000TPA utilizes advanced ceramic heating technology, which heats up quickly and provides uniform warmth. The ceramic plates within the unit warm up rapidly, ensuring that the surrounding area is heated efficiently and evenly. This technology also contributes to longer-lasting performance, reducing wear and tear over time.

User convenience is further enhanced through an integrated digital display that makes it easy to monitor and adjust settings. The unit also features a remote control, allowing users to operate the heater from a distance without needing to get up, which adds a layer of convenience, especially in larger spaces.

Safety is a crucial aspect of the design of the VMH3000TPA. It is equipped with multiple safety features, including overheat protection and tip-over switches, which automatically shut off the heater if it is tipped over or if it exceeds safe temperature levels. These safety mechanisms provide peace of mind for users, knowing that the heater operates within safe parameters.

In terms of aesthetic appeal, the VMH3000TPA sports a modern and sleek design that seamlessly integrates into various interior styles, enhancing the overall ambiance of the space it occupies. The lightweight construction ensures ease of mobility, allowing users to move it from room to room as needed.

Overall, the Vanguard Heating VMH3000TPA stands out in the market for its powerful heating capabilities, energy efficiency, advanced safety features, and user-friendly design, making it a top choice for individuals seeking reliable heating solutions for diverse environments.