Vanguard Heating VMH10TNB installation manual Optional Mantel Installation

Page 10

®VMH10TNB

VENT-FREE NATURAL GAS COMPACT FIREPLACE

INSTALLATION

Continued

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: Surface temperatures of adjacent walls and mantels be- come hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these tempera- tures meet the requirement of the national product standard. Fol- low all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

raise the mantel to an accept- able height

remove the mantel

Mantel Shelf

Note:

10"

8"

All vertical

measurements

6"

are from top of

2 1/2"

fireplace

opening to bottom of mantel shelf. All measurements are in inches.

13"

16"

19"

21"

OPTIONAL MANTEL

INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installa- tion. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3400T, pages 11 through 13).

1.Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base as- sembly.

4.Assemble brass trim kit. See Assem- bling Brass Trim, page 11.

5.Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 13).

6.Align brass trim kit for flush fit around opening.

7.Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 13).

Shoulder

Screws

Hole for 3" Wood Screw

for Attaching Fireplace to Mantel

Assembled

Brass Trim

8.Place assembly next to wall at installa- tion location.

9.Remove brass trim kit and mantel. Be careful not to damage wall or mantel.

10.Attach wood base to floor with two 1 3/4" black screws provided (see Figure 14). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 14).

11.Install gas line. See Connecting To Gas Supply, page 14.

12.Check for leaks. See Checking Gas Connections, page 16.

13.Place mantel around fireplace. Be care- ful not to damage wall or mantel.

14.Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 13).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the man- tel. The openings are located at top be- hind the area for the brass louvers (see Figure 13).

16.Reinstall top brass louvers.

Hole for 3" Wood Screw for Attaching Fireplace to Wooden Base

Side of

Firebox

Figure 12 - Minimum Mantel Clearances for Built-In Installation

Figure 13 - Attaching Brass Trim to Fireplace

1 3/4" Screw

Wood Base

Figure 14 - Attaching Wood Base to Floor

10

107031

Image 10
Contents VENT-FREE Natural GAS Compact Classic Hearth Fireplace What to do if YOU Smell GASSafety Information VMH10TNBUnpacking Product FeaturesProduct Identification Local CodesAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Wall openingOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Assembly Installing Blower Accessory GA3400TRemoving Upper Louver Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve For Built-In Installation Extension CordConnecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOperating Blower Pilot Flame Pattern Inspecting BurnerBurner Flame Pattern Troubleshooting Observed Problem Possible Cause RemedyClean burner see Cleaning and Mainte Gas leak. See Warning statement at Technical Service Cleaning and MaintenanceService Hints Cleaning Burner Injector Holder and Pilot AIR Inlet HoleIllustrated Parts Breakdown VMH10TNB17Parts List VMH10TNBParts Under Warranty SpecificationsReplacement Parts Parts not Under WarrantyAccessories Warranty Information