Vanguard Heating VP26T, VP16T, VN30T, VN18T Thermostat Sensing Bulb, Installing Heater to Wall

Page 8

8

INSTALLATION

Thermostat Sensing Bulb Installing Heater To Wall

INSTALLATION

Continued

THERMOSTAT SENSING BULB

(Thermostat Models Only)

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Removing Front Panel Of Heater

1.Remove the four painted screws, two on each side of front panel.

2.Pull bottom of front panel forward, then out.

3.Remove any remaining packaging materials.

Locating Thermostat Sensing Bulb (for thermostat applications)

1.Remove front panel of heater (see Figure 7).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat Sensing Bulb

Clamp

Figure 5 - Attaching Thermostat Sensing Bulb

INSTALLING HEATER TO WALL

Mounting Bracket

Locate mounting bracket in heater carton. Remove mounting bracket from heater carton.

Figure 7 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14 inches apart from their centers. Attach mounting bracket to wall in one of two ways:

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 8, page 9. If you can, provide greater clear- ances from floor and joining wall.

Figure 6 - Mounting Bracket

For..com

107887

Image 8
Contents What to do if YOU Smell GAS Safety Information and Installation ManualVP16IT, VN18IT VP22IT, VN25IT Table of Contents Safety InformationProduct Features Product IdentificationUnpacking Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbAttaching Mounting Bracket To Wall Placing Heater On Mounting BracketInstalling Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions NON-THERMOSTAT Models For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure Thermostat Models For Your Safety Read Before LightingTo Select Heating Level To Turn OFF GAS to ApplianceThermostat Models Thermostat Operation Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30ITCleaning and Maintenance Inspecting HeaterSpecifications VN25ITTroubleshooting Observed Problem Possible Cause RemedyAfter ODS/pilot lights, keep control Observed Problem Possible Cause Illustrated Parts Breakdown Cabinet BodyParts List VN30T Description QTYCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY Burner Assembly VP16, VN18, VP16T, VN18T, VP16IT, VN18ITVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Replacement Parts Service HintsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 107887 Warranty Information

VN18, VN18IT, VP16IT, VN25IT, VP26T specifications

Vanguard Heating offers a range of innovative heating solutions, including the VP16T, VP22IT, VN18T, VP16IT, and VP26 models. Each of these heaters is designed to provide efficient and reliable warmth for various spaces, making them suitable for both residential and commercial use.

The VP16T model is known for its compact size and powerful heating capabilities. It features an adjustable thermostat that allows users to maintain their desired temperature effortlessly. Designed for energy efficiency, the VP16T operates with minimal energy consumption while delivering consistent heat output. Its lightweight construction makes it easy to move and install in different areas as needed.

The VP22IT model expands on the VP16T's features, incorporating advanced technology for improved performance. It comes with a built-in timer function, allowing users to program their heating schedule. This feature enhances energy savings and convenience, as the heater can automatically turn on or off based on individual preferences. Additionally, the VP22IT includes a safety shut-off mechanism that activates in case of overheating, ensuring safe operation.

The VN18T is designed for versatile applications, featuring multi-directional airflow for optimized heating distribution. It is equipped with robust heating elements that provide quick warmth in a matter of minutes. This model is particularly popular for larger spaces due to its high heating capacity. The VN18T also includes a user-friendly digital control panel, making it easy to adjust settings.

The VP16IT combines the strengths of its predecessors, integrating smart technology for enhanced user experience. It features Wi-Fi connectivity, allowing users to control the heater remotely using a smartphone app. This model also supports voice command integration, making it compatible with smart home systems. Its sleek design adds a modern touch to any environment.

Lastly, the VP26 model offers the highest heating output among the Vanguard lineup. Tailored for large areas, it incorporates a dual-zone heating system that optimizes performance based on room size and heating requirements. Its advanced thermal insulation technology minimizes heat loss, contributing to efficiency and reduced energy costs.

In conclusion, Vanguard Heating's selection of VP16T, VP22IT, VN18T, VP16IT, and VP26 models features innovative technologies, safety measures, and user-friendly controls. These heaters are engineered to provide effective heating solutions that prioritize efficiency, convenience, and safety, making them a top choice for consumers seeking reliable warmth in any setting.