Liebert 60 HZ manual Drycooler physical data

Page 11

Table 5

Drycooler physical data

 

 

 

 

 

 

Drycooler

Circuits

 

A

B

C

L

#Fans

Conn FNPT

Model

 

& Motors**

In/Out

Standard Models

 

 

 

 

 

 

 

 

-033

 

any

 

42

-

44

51.5

1

3/4

-069

 

any

 

42

-

44

51.5

1

1-1/4

-092

 

any

 

42

-

44

51.5

1

1-1/2

-109

 

any

 

42

-

44

51.5

1

2

-112

 

any

 

42

-

44

51.5

1

2

-139

 

any

 

82

-

84

91.5

2

2

-174

 

any

 

82

-

84

91.5

2

2

-197

 

any

 

82

-

84

91.5

2

2

-225

 

any

 

82

-

84

91.5

2

2

-260

 

any

 

122

-

124

131.5

3

2

-310

 

any

 

122

-

124

131.5

3

2

-350

 

any

 

122

-

124

131.5

3

2

-352

 

any

 

82

80

164

171.5

4

2

-419

 

any

 

82

80

164

171.5

4

2

-466

 

any

 

82

80

164

171.5

4

2-1/2

-491

 

any

 

82

80

164

171.5

4

2-1/2

-620

 

641

 

122

124

131.5

6

2) 2-1/8*

 

-620

 

32

 

122

124

131.5

6

2) 2-1/8*

 

-650

 

80

 

122

124

131.5

6

4) 2-1/8*

 

-650

 

521

 

122

124

131.5

6

2) 2-1/8*

 

-650

 

40

 

122

124

131.5

6

2) 2-1/8*

 

-700

 

96

 

122

124

131.5

6

4) 2-1/8*

 

-700

 

641

 

122

124

131.5

6

2) 2-1/8*

 

-700

 

32

 

122

124

131.5

6

2) 2-1/8*

 

-790

 

641

 

82

80

164

171.5

8

2) 2-1/8*

-790

 

32

 

82

80

164

171.5

8

2) 2-1/8*

-880

 

801

 

82

80

164

171.5

8

4) 2-1/8*

-880

 

52

 

82

80

164

171.5

8

2) 2-1/8*

-940

 

961

 

82

80

164

171.5

8

4) 2-1/8*

-940

 

64

 

82

80

164

171.5

8

2) 2-1/8*

-940

 

32

 

82

80

164

171.5

8

2) 2-1/8*

Quiet-Line Models

 

 

 

 

 

 

 

 

-040

 

any

 

42

-

44

51.5

1

1-1/4

-057

 

any

 

42

-

44

51.5

1

1-1/2

-060

 

any

 

42

-

44

51.5

1

 

-080

 

any

 

82

-

84

91.5

2

2

-111

 

any

 

82

-

84

91.5

2

2

-121

 

any

 

82

-

84

91.5

2

2

-158

 

any

 

122

-

124

131.5

3

2

-173

 

any

 

122

-

124

131.5

3

2

-178

 

any

 

122

-

124

131.5

3

2

-205

 

any

 

82

80

164

171.5

4

2

-248

 

any

 

82

80

164

171.5

4

2

-347

 

any

 

122

-

124

131.5

6

2) 2-1/8*

-356

 

641

 

122

-

124

131.5

6

2) 2-1/8*

-356

 

32

 

122

-

124

131.5

6

2) 2-1/8*

-453

 

641

 

82

80

164

171.5

8

2) 2-1/8*

-453

 

32

 

82

80

164

171.5

8

2) 2-1/8*

-498

 

961

 

82

80

164

171.5

8

4) 2-1/8*

-498

 

64

 

82

80

164

171.5

8

2) 2-1/8*

-498

 

32

 

82

80

164

171.5

8

2) 2-1/8*

*Connections are ODS

**Motors are 3/4 HP - standard models; 1/4 HP - Quiet-Line models

1. Standard circuiting

7

Image 11
Contents Heat Removal /ENVIRONMENTAL Control Drycoolers 60 HzPage Table of Contents Figures No Pump Liebert DrycoolersLow Noise Level Features and Benefits of Liebert DrycoolersEasy Installation and Service Heat Rejection ModuleAltitude correction Selection ProcedureExample Determining actual Btuh and MBHPD ft. water Performance DataNo. Number Range CircuitsQuiet-Line Models Capacity correction factorDimensional Data Drycooler physical data Drycooler electrical data Electrical DataDrycooler electrical data-Quietline models Guide Specifications Component ASSEMBLY/INSTALLATION Location Guidelines APPLICATION/INSTALLATION GuidelinesPump curve, 60 Hz Pump Packages & Expansion Tank OptionsExpansion Tank- P/N 1C16717P1 Pump dataSupplementary Application Data Maintenance GuidelinesRoom dew point temperatures Volume in standard tubePage Web Site Mail Heat REMOVAL/ENVIRONMENTAL ControlUnited States

60 HZ specifications

The Liebert 60 Hz represents a significant breakthrough in the realm of power management and cooling solutions, specifically tailored for the demands of modern IT environments. Engineered by Vertiv, the Liebert brand is synonymous with reliability and innovation, and this model is no exception.

One of the standout features of the Liebert 60 Hz is its advanced design, which incorporates cutting-edge thermal management technologies. The system is adept at maintaining optimal operating temperatures for critical equipment, ensuring maximized uptime and increased operational efficiency. The integration of high-performance cooling solutions means that even during peak load conditions, the Liebert 60 Hz can operate effectively without compromising performance.

The unit operates at 60 Hz, making it compatible with North American power systems, an essential factor for many commercial and industrial setups. This frequency standard allows for seamless integration into existing electrical configurations, reducing installation challenges and costs. Coupled with its compact footprint, the Liebert 60 Hz is ideal for environments where space is at a premium.

In terms of energy efficiency, the Liebert 60 Hz utilizes state-of-the-art variable speed technology. This allows the system to adjust cooling output based on real-time environmental conditions, significantly reducing energy consumption while maintaining necessary cooling levels. The result is a lower carbon footprint and reduced operational costs, which is a critical consideration for organizations focused on sustainability.

Another notable characteristic of the Liebert 60 Hz is its modular design. This allows for easy scalability, making it an excellent choice for growing businesses. As IT demands increase, additional units can be added without extensive renovations or disruptions to existing setups. Furthermore, the system includes intelligent monitoring capabilities that provide real-time data on performance, enabling proactive management and maintenance.

In summary, the Liebert 60 Hz is a robust, efficient, and scalable power management solution designed to meet the rigorous demands of contemporary IT infrastructures. With its energy-efficient cooling, modular design, and ability to operate seamlessly within North American power grids, it stands out as a leading choice for businesses aiming to enhance their operational resilience and efficiency. Whether for data centers, telecommunications, or critical infrastructure, the Liebert 60 Hz proves to be an invaluable asset in modern technology landscapes.