Before Use

Important!

Leave the unit in an upright position for at least 2 hours before use.

Always place the unit on an even surface.

The power cord has a built-in L.C.D.I. (Leakage, Current, Detection, Interruption) circuit breaker for added safety. If the power supply is interrupted, please press the reset button to reconnect the unit to the power source. The green light should be on.

Make sure the unit is connected to a correctly grounded power supply.

For proper operation, the unit must be vented to the outside.

Do not cover or obstruct the appliance inlet or outlet grilles.

To avoid the risk of shock, the product should never be used in bathrooms, shower rooms or in any other steamy or wet areas.

Always transport the unit in an upright position.

Do not sit or stand on the unit.

Do not place objects on the unit.

Do not touch the unit with wet/damp hands or when standing barefoot.

Drainage of the water container is required before moving the unit or putting it into storage.

If the electric socket is different from the plug provided, have a professionally qualified electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple sockets and/or extension cords; if their use is necessary, ensure that they conform to the current safety regulations.

Do not pull the power cord or place it near a source of heat; always unroll it completely to avoid the possibility of dangerous overheating.

If the power cord is damaged, it must be replaced by a qualified person.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

Operation

Setting The Fan Speed

Press the SPEED button to choose the fan speed you require, high or low.

The indicator of high or low fan will light up at the same time.

If the unit is in AUTO mode, it will select the fan speed automatically according to the ambient temperature (the related indicators, cool, fan or heat will light up), at this time the fan speed switch is invalid.

Setting the Timer

Press the TIMER button to set the operating hours you desire (1 to 12 hours, the timer indicator will light up). When the set time has elapsed, the machine will turn off automatically. The display window will show the hour(s) you set as you press the TIMER button. If the timer button is not pressed, the unit will work continuously.

By pressing the timer button but without turning on the unit, you can PRE-SET the time for the machine to work. For example, if you press the timer to ‘2’,

the unit will come on automatically after 2 hours.

All the above functions can also be performed with the supplied remote control. This remote control requires 2 AAA batteries to operate.

Regulating the Airflow Direction

Turn the roller on the air vent to control

Move the air vent directly to adjust the

the airflow direction from the vertical louvres.

airflow direction from the horizontal louvres.

IMPORTANT!

The compressor will start approximately 3 minutes after the unit is turned on (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on.

The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps working at the set level. If the ambient temperature rises above the chosen temperature +/-5°F,

the cooling will resume.

In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set (the fan keeps working at the set level). When the room temperature drops 5°F below the chosen temperature, heating will resume.

This machine is equipped with an ANTI-FROST function. Sometimes, while using the heating function during low temperatures, the heating will stop for a while to melt the internal frost. When this occurs, wait for heating to resume.

As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.

4

9

Image 6
Contents OneYear Limited Warranty Product Amcor Portable Air ConditionerTroubleshooting Table of ContentsDrainage SpecificationsHow to Drain the Unit Use a Shallow Container or Dish Turn off the unitParts Accessories10Operation Control PanelCleaning the Filter Wall Connection InstallationMounting the Exhaust Pipe Window Kit Installation Make a hole 5.1 in diameter in the wallBefore Use Setting The Fan SpeedSetting the Timer Regulating the Airflow DirectionMaintenance Thank You

000E/EH specifications

Amcor 000E/EH is a remarkable packaging solution that showcases the company's commitment to innovation and sustainability. This product line is designed for various applications, primarily focusing on the food and beverage industry, where preserving product quality and extending shelf life are critical.

One of the standout features of the Amcor 000E/EH is its advanced barrier technologies. These technologies are engineered to protect against oxygen, moisture, and light, ensuring that products remain fresh and retain their flavors and nutrients throughout their shelf life. The multi-layer structure of the packaging provides enhanced performance, making it suitable for both dry and wet products.

The Amcor 000E/EH packaging is also highly versatile in design. It can be customized to meet the specific needs of different brands and products, whether in terms of size, shape, or print design. This flexibility allows manufacturers to present their products attractively while standing out on retail shelves.

In addition to its protective properties, the Amcor 000E/EH packaging is designed with sustainability in mind. As consumer demand for environmentally friendly packaging continues to rise, Amcor has developed solutions that utilize recyclable materials and reduce overall environmental impact. The company has committed to ensuring that all of its products are capable of being recycled, making Amcor 000E/EH a strong choice for brands looking to enhance their sustainability credentials.

Another key characteristic of the Amcor 000E/EH is its ease of use. The packaging can be seamlessly integrated into existing production lines without significant modifications, facilitating a smooth transition for manufacturers. This aspect not only saves time but also reduces operational costs associated with switching to new packaging solutions.

Furthermore, the Amcor 000E/EH complies with all relevant food safety regulations and standards, providing peace of mind to both manufacturers and consumers. This compliance ensures that the packaging is safe and reliable for containing food products, a vital aspect in today’s health-conscious market.

In summary, Amcor 000E/EH is an advanced packaging solution characterized by its exceptional barrier properties, customizable design, sustainability features, user-friendliness, and compliance with safety regulations. These qualities make it an ideal choice for businesses in the competitive food and beverage sector, helping them to protect their products while also appealing to environmentally conscious consumers.