Operation

Automatic Mode Indicator

Cooling Mode Indicator

High Fan Speed Indicator

 

Fan Mode Indicator

Low Fan Speed Indicator

 

 

 

Heating Mode Indicator

Room Temperature Indicator

 

 

 

 

(For Models With Heating Options)

 

 

 

 

Timer Operation Indicator

Set Temperature Indicator

 

 

 

 

 

 

 

 

 

 

Compressor Indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Up Selector

Temperature Down SelectorOn/Off (Power) Selector

Fan Speed Selector Mode (Function) Timer Selector

Option Selector

Setting Mode/Function

Press the MODE button to select the required working mode:Automatic, Cooling, Fan or Heating (Heating is only available for AL-10,000EH).The green indicator illustrating your selected mode lights up. It is recommended to select Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please see below) that cannot be changed.

The indicators of the functions in progress come on at the same time, e.g. Cool and Lo = Cooling mode with Low fan speed.

Auto Mode

When this mode is selected, the unit is preset to the following temperature settings and unit will only start to:

Cool when room temperature is higher than 75ºF

Heat when room temperature is lower than 68ºF (AL-10,000EH only)

If room temperature is between 68ºF and 75ºF, unit will stay in Fan mode. Again, when in Auto Mode, the temperature settings cannot be changed.

Setting the Temperature in Cooling or Heating Mode

The display window’s default is to display the ambient room temperature. The green indicator light under RT is on. (RT = Room Temperature)

To set your desired temperature, press the Temperature up or down buttons (ranging from 62ºF to 90ºF). Each press will increase or decrease your set temperature by 1ºF. When pressing the temperature up or down buttons, the window will change to display your set temperature.At this time, the green indicator will light under ST (Set Temperature). Once the temperature up or down buttons is released, the window will return to displaying the ambient temperature after a second.

Note: When unit is in the following modes: Auto, Cool, or Heat - the compressor will cool/heat the room to reach the set temperature. Once the ambient temperature has reached the set temperature, the compressor will stop and unit will run in Fan mode. To conserve energy, the compressor will not start immediately after a couple degrees increase or decrease, but will wait for a 5ºF allowance. For example:

In Cooling Mode with a set temperature of 70ºF

When compressor first stops after reaching 70ºF, unit will auto-switch to Fan.

Compressor will start cooling again when ambient temperature increases to 75ºF or above.

In Heating Mode with a set temperature of 72ºF

When compressor first stops after reaching 72ºF, unit will auto-switch to Fan. Compressor will start heating again when ambient temperature drops to 67ºF or below.

In Auto Mode (with preset temperature of 68ºF for heat and 75ºF for cool)

Compressor will start cooling again when ambient temperature reaches above 80ºF or will start heating when ambient temperature drops below 63ºF.

Parts

Front

Back

1 2

3

4

1.

Control Panel

5.

Air Filter

2.

Cooling Air Outlet

6.

Air Inlet

3.

Handle

7.

Exhaust Air Outlet

4.

Castors

8.

Cord Hanger

 

 

9.

Water Stopper (Rubber Plug Inside)

 

 

 

 

Accessories10

10. Adaptor - for insertion over the

hose and into the back of the12 air conditioner

11. Exhaust Hose

12. Adjustable Slide Bar

11

 

13. Round Connector

13

14.Cap for Round Connector

15.Remote Control

(Electronic control models only)

14

 

15

8

5

Image 4
Contents OneYear Limited Warranty Product Amcor Portable Air ConditionerTroubleshooting Table of ContentsSpecifications How to Drain the UnitDrainage Use a Shallow Container or Dish Turn off the unitOperation Accessories10Parts Installation Mounting the Exhaust Pipe Window Kit InstallationCleaning the Filter Wall ConnectionSetting The Fan Speed Setting the TimerBefore Use Regulating the Airflow DirectionMaintenance Storing The Power CordThank You Energy Saving Tips

000E AL-10 specifications

Amcor 000E AL-10: Cutting-Edge Packaging Solution

Amcor 000E AL-10 is a state-of-the-art packaging innovation that leverages advanced technologies to provide producers with a high-performance solution designed for various packaging needs. This product is specifically engineered to deliver robust protection, enhanced shelf life, and improved product presentation. It is particularly popular in industries ranging from food and beverage to pharmaceuticals.

One of the main features of Amcor 000E AL-10 is its multilayer construction, which combines the best attributes of different materials. The layers typically include a combination of aluminum foil, polymer layers, and other barrier materials. This construction ensures an exceptional barrier against oxygen, moisture, and light, which are critical factors in preserving the quality and integrity of products.

In terms of technologies employed, Amcor 000E AL-10 utilizes a unique extrusion process that allows for uniform thickness across the packaging material. This uniformity not only enhances the mechanical properties of the package but also simplifies the manufacturing process. The associated quality control measures ensure that every batch meets stringent performance standards.

This packaging solution is designed with user convenience in mind. Its lightweight nature reduces shipping costs, while its durability ensures that products remain protected during transit and storage. Additionally, Amcor 000E AL-10 can be easily printed on, allowing brands to highlight their products with high-quality graphics and necessary regulatory information.

The characteristics of Amcor 000E AL-10 include its flexibility and ability to conform to various shapes and sizes, making it suitable for different product types. It can be heat-sealed to provide tamper-evident packaging, reinforcing the safety aspect of the products it encases. Moreover, Amcor has focused on sustainability with this packaging solution, ensuring that materials used in the production of the 000E AL-10 can be recycled or have reduced environmental impact.

Overall, Amcor 000E AL-10 is a versatile and technically advanced packaging solution that meets the demands of modern consumers and manufacturers alike. Its blend of protection, convenience, and sustainability makes it an ideal choice for businesses looking to enhance their product offerings while maintaining a competitive edge in the market.