Induction Heater C Library User Manual Version 1.2
6. System Operate
6.1. Key & Led Definition
The system key buttons and leds are defined as below.
Error |
| Timer |
| CaoCai |
| HuoGuo |
Clear |
| Timer |
Inc |
| Dec |
DunCai BaoTang BaoWen Power
View |
| Power |
|
Key Define
Clear the timer. | |
Set the timer. | |
Power increase. | |
Power decrease. | |
Mode increase. | |
Mode decrease. | |
Change the display, power or timer. | |
Turn on or turn off the device. |
Led Define
Error display. | |
Timer display. | |
Mode display. | |
Mode display. | |
Mode display. | |
Mode display. | |
Mode display. | |
Power display. |
Error Code
Error Code | Description | Notes |
|
|
|
0xE0 | Power under voltage |
|
|
|
|
0xE1 | Power over voltage |
|
|
|
|
0xE2 | Power over current |
|
|
|
|
0xE3 | Main sensor over 300℃ |
|
|
|
|
0xE4 | Main sensor break circuit |
|
|
|
|
0xE5 | Main sensor short circuit |
|
|
|
|
0xE6 | Main sensor temp not change |
|
|
|
|
0xE7 | IGBT temp over 120℃ |
|
|
|
|
0xE8 | IGBT sensor break circuit |
|
|
|
|
0xE9 | IGBT sensor short circuit |
|
|
|
|
0xF0 | Kettle is empty |
|
|
|
|
0xF1 |
|
|
|
|
|