Empire Comfort Systems RH-65-6, RH-50-6, RH50C-1, RH-65C-1 Introduction, Specifications

Page 5

INTRODUCTION

Introduction

Always consult your local Building Department regarding regu- lations, codes or ordinances which apply to the installation of a vented room heater.

Instructions to Installer

1.Installer must leave instruction manual with owner after instal- lation.

2.Installer must have owner fill out and mail warranty card sup- plied with heater.

3.Installer should show owner how to start and operate heater and thermostat.

General Information

This series is design certified in accordance withAmerican National Standard/CSAStandard Z21.86 and CSA2.32 by the Canadian Stan- dards Association, as a Vented Room Heater and must be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and com- pany making the change.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

Notice: During initial firing of this unit, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor.

Floor pad is available from Empire Comfort Systems, Inc., Part Number RH-425.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company which whether in person or through a representative is engaged in and is respon- sible for (1) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must by made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1*/ Canadian Installation Code, CAN/CGA B149.

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Canadian High Altitudes for locations having an eleva- tion above mean sea level between 2,000 feet (610m) and 4,500 feet (1370m), the manifold pressure is to be decreased from 4.0” w.c. (.996kPa) to 3.2” w.c. (.797kPa) for Natural Gas and from 10.0” w.c. (2.49kPa) to 8.0” w.c. (1.99kPa) for Propane Gas.

SPECIFICATIONS

Models

RH-50B

RH-65B

RH-50C

RH-65C

RH-50CB

RH-65CB

Input BTU/HR (KW/H)

50,000 (14.6)

65,000 (19)

50,000 (14.6)

65,000 (19)

50,000 (14.6)

65,000 (19)

 

 

 

 

 

 

 

Height

29 9/16” (751mm)

29 9/16” (751mm)

29 9/16” (751mm)

29 9/16” (751mm)

29 9/16” (751mm)

29 9/16” (751mm)

 

 

 

 

 

 

 

Width

34” (864mm)

34” (864mm)

34” (864mm)

34” (864mm)

34” (864mm)

34” (864mm)

 

 

 

 

 

 

 

Depth including diverter

23 3/16” (589mm)

27 11/16” (704mm)

23 3/16” (589mm)

27 11/16” (704mm)

23 3/16” (589mm)

27 11/16” (704mm)

Gas Inlet

1/2” (13mm)

1/2” (13mm)

1/2” (13mm)

1/2” (13mm

1/2” (13mm)

1/2” (13mm)

 

 

 

 

 

 

 

Size Draft Diverter Collar

5” (127mm)

5” (127mm)

5” (127mm)

5” (127mm)

5” (127mm)

5” (127mm)

 

 

 

 

 

 

 

Floor to top of collar on vertical

27 5/32” (690mm)

27 5/32” (690mm)

27 5/32” (690mm)

27 5/32” (690mm)

27 5/32” (690mm)

27 5/32” (690mm)

position of Draft Diverter

 

 

 

 

 

 

Floor to center of collar on

22 9/16” (573mm)

22 9/16” (573mm)

22 9/16” (573mm)

22 9/16” (573mm)

22 9/16” (573mm)

22 9/16” (573mm)

horizontal position of Draft Diverter

 

 

 

 

 

 

Accessories

 

 

 

 

 

 

Blower Package

Included

Included

FRB-3

FRB-3

Included

Included

 

 

 

 

 

 

 

Radiant Package

RAD-8

RAD-8

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

Floor Pad

RH-425

RH-425

RH-425

RH-425

RH-425

RH-425

 

 

 

 

 

 

 

Ceramic Log

RHL-1

RHL-1

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

Page 5

12822-4-0806

 

Image 5
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsGAS Supply Installing a New Main Gas CockRecommended Gas Pipe Diameter Checking Manifold PressureLiner and Insulated Liner ClearancesVenting Thermostat Operation Vent Safety Shutoff Systemfire Lighting InstructionsTechnician. Force or attempted repair may result in a fire Or explosionMain Burner Flame Characteristics Pilot Flame CharacteristicsPrimary Air Adjustment see On Propane gas, if a whistling noise resonation occursTroubleshooting MaintenanceParts List RH-50 & RH-65 HOW to Order Repair PartsParts View RH-50 & RH-65 Index Part Description Number Parts List RH-50C & RH-65CParts View RH-50C & RH-65C Optional Blower Installation Instructions Wiring Diagram WiringFan Control OilingService Notes Service Notes Service Notes
Related manuals
Manual 18 pages 15.51 Kb

RH-65-6, RH-65C-1, RH-50-6, RH50C-1 specifications

Empire Comfort Systems has long been a trusted name in the heating solutions market, and their RH series of direct-vent gas heaters exemplifies their commitment to quality and innovation. Among the models in this series, the RH-50-6, RH-65-6, RH-65C-1, and RH-50C-1 stand out for their exceptional performance and user-friendly features.

The RH-50-6 offers a heat output of 50,000 BTUs, making it ideal for smaller spaces needing effective, efficient heating. It features a sleek design and a variety of style options, ensuring it can fit seamlessly into any room. Its direct vent system allows for safe and efficient operation, drawing air from the outside while expelling exhaust gases, thus creating a comfortable indoor environment without compromising indoor air quality.

Similarly, the RH-65-6 model provides a higher output of 65,000 BTUs, suitable for medium to larger areas. This model emphasizes user control with an optional remote control feature, allowing homeowners to adjust the thermostat from the comfort of their couch. The easy-to-use control panel enhances operation simplicity, catering to users of all levels of technical know-how.

The RH-65C-1 and RH-50C-1 models bring additional benefits through their contemporary styling and advanced features. Both units include Empire's exclusive Comfort Control technology. This system optimizes heat distribution throughout the room, ensuring that users experience consistent warmth without hot or cold spots. Alongside aesthetic choices, such as ceramic glass fronts and versatile trim options, these models are designed to provide both functionality and style.

One significant feature across the RH series is the emphasis on energy efficiency. These models meet stringent energy standards, helping homeowners save on utility bills while minimizing environmental impact. The advanced burner technology ensures a clean burn with minimal emissions, aligning with sustainable heating practices.

In conclusion, the Empire Comfort Systems RH-50-6, RH-65-6, RH-65C-1, and RH-50C-1 represent a blend of traditional craftsmanship and modern technology. With various BTU outputs, user-friendly controls, and striking designs, they cater to diverse heating needs, making them outstanding choices for those seeking reliable and efficient home heating solutions.