Enerco HS85FAV, MH125FAV, MH85FAV Odor Fade Warning, Fuel GAS Odor, Odor Fading no Odor Detected

Page 5

ODOR FADE WARNING

WARNING

Asphyxiation Hazard

Do not use this heater for heating human living quarters.

Do not use in unventilated areas.

The flow of combustion and ventilation air must not be obstructed.

Proper ventilation air must be provided to support the combustion air requirements of the heater being used.

Refer to the specification section of the heater’s manual, heater dataplate, or contact the factory to determine combustion air ventilation requirements of the heater.

Lack of proper ventilation air will lead to improper combustion.

Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches, dizziness and difficulty in breathing.

FUEL GAS ODOR

LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.

If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!

Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.

Get everyone out of the building and away from the areaimmediately.

Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.

Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.

Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area.

Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.

FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.

ODOR FADING - NO ODOR DETECTED

Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.

Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.

Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.

The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade undersomecircumstances.

If there is an underground leak, the movement of gas through the soil can filter the odorant.

Propane (LP) gas odor may differ in intensity at different levels.SincePropane(LP)gasisheavierthanair,there may be more odor at lower levels.

Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussedpreviously.

ATTENTION - CRITICAL POINTS TO REMEMBER!

Propane (LP) gas has a distinctive odor. Learn to recognizetheseodors.(ReferenceFuelGasOdorand OdorFadingsectionsabove.

Even If you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.

If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.

A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amountofgas,CONTACTYOURFUELGASSUPPLIER

IMMEDIATELY.DONOTWAIT!

Enerco Group, Inc. Forced Air Propane Construction Heater

5

Operating Instructions and Owner’s Manual

Image 5
Contents Heatstar General Hazard Warning ContentsSpecifications 125FAV Operating PrecautionsModel Clearance Safety PrecautionsOpening Heater Near floor Odor Fading no Odor Detected Odor Fade WarningFuel GAS Odor Servicing Operating Instructions125,000 BTU/HR 49.1 kW Size and Capacity of Propane Cylinders RequiredColor Length From Wiring DiagramsItem # Description QTY Parts Ordering Information For Information Regarding ServiceInstructions LES Soigneusement Lisez Pièces DE Commande LA SUR InformationsService LE SUR Informations DES Obtenir Pour 85FAV 55FAV Longueur Câblage DE SchémasOFoC-TEMPÉRATUREDELAIR Entreposageetentretien EntretienArrêt DémarrageOdorantessubstancesauxliéavertissement IMMÉDIATEMENT!INTERVENIRFAUTQUILSIGNALPlancher du près Chauffage de Appareil Ouverture Sécurité LA À Liées Précautions125 85, 55, pulsé Air Écart 55FAV Modèle SpécificationsMatières DES Table Instructionslessoigneusementlisez Gazdeodeurduneprésenceen

HS125FAV, HS55FAV, HS85FAV, MH55FAV, MH125FAV specifications

Enerco's series of industrial heaters, including the TS55FAV, HS85FAV, MH55FAV, MH85FAV, and MH125FAV models, are designed to provide efficient, reliable heating solutions for various applications. These heaters cater to diverse needs, from construction sites to workshops, ensuring optimal comfort and safety even under challenging conditions.

The Enerco TS55FAV model stands out for its portable design and substantial heating capacity. It offers an impressive 55,000 BTU output, making it suitable for medium-sized spaces. Its advanced safety features, including a tip-over shut-off switch and a built-in thermostat, help maintain a stable environment. The durable construction ensures longevity while being easy to transport.

Next in the lineup is the HS85FAV, which delivers an output of up to 85,000 BTUs. This model is particularly noted for its efficient fuel consumption and exceptional performance. The HS85FAV incorporates a forced air system, ensuring quick heat distribution. Its rugged design makes it ideal for outdoor use in harsh weather conditions.

The MH55FAV brings versatility to the series by offering both direct and indirect heating options. This model's 55,000 BTU output makes it a reliable choice for temporary heating needs. It utilizes innovative technology that allows for the efficient burning of fuels while minimizing emissions. Additionally, the MH55FAV features a sturdy frame that allows for easy mobility across job sites.

The MH85FAV is an upgrade, pushing the output to 85,000 BTUs, further enhancing its capability for larger spaces. It carries the same focus on environmental considerations with low emissions and high fuel efficiency. The MH85FAV's ergonomic design and ease of use simplify operation, making it a preferred option for contractors.

At the top of the range is the MH125FAV, boasting an impressive output of 125,000 BTUs. This model is engineered for heavy-duty applications, delivering robust heating for extensive areas. Its built-in thermostat and safety shut-off features ensure that users can operate it with confidence. The MH125FAV also includes a high-performance blower for optimal heat dispersal, making it ideal for challenging industrial environments.

In summary, the Enerco heaters TS55FAV, HS85FAV, MH55FAV, MH85FAV, and MH125FAV represent a comprehensive range of heating solutions, each equipped with unique features and technologies designed for performance, safety, and efficiency. Whether for construction, industrial facilities, or outdoor events, these models meet the diverse requirements of users, ensuring warm environments in various settings.