Enerco owner manual General Recommendations, Mh 4000DF Mh 6000DF

Page 3

Important

Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.

General Recommendations

The direct-fired heater runs on diesel fuel. This direct combustion heater exhausts hot air and the combustion products into

the room, while those with indirect combustion are fitted with a flue to take the fumes away through the chimney.

Always follow local ordinances and codes when using this heater:

Read and follow this owner’s manual before using the heater.

Use only in places free of flammable vapors or high dust content.

Never use heater in immediate proximity of flammable materials (the minimum distance must be 6 ft.).

Make sure fire fighting equipment is readily available.

Make sure sufficient fresh outside air is provided according to the heater requirements. Direct combustion heaters should only be used in well vented areas in order to avoid carbon monoxide poisoning.

Never block air inlet (rear) or air outlet (front).

In case of very low temperatures add kerosene to the heating oil.

Make sure heater is always under surveillance and keep children and animals away from it;

Before starting the heater always check free rotation of ventilator fan.

Unplug heater when not in use.

TECHNICAL SPECIFICATIONS

 

mh 4000DF

 

mh 6000DF

 

hs 4000DF

 

hs 6000DF

 

 

 

 

 

 

 

 

 

 

 

 

Heat input

 

[kBTU/h]

400

 

610

 

 

 

 

 

 

 

Air flow

 

[cfm]

2.500

 

2.800

 

 

 

 

 

 

 

Fuel Type

 

 

 

Diesel/Kerosene/#1-2 Fuel Oil

 

 

 

 

 

 

Heat output

 

[kBTU/h]

-

 

-

 

 

 

 

 

 

 

Fuel consumption

 

[gal/h]

12.83

 

4.46

 

 

 

 

 

 

[lb/h]

19.58

 

30.84

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

1

 

1

 

 

 

 

 

 

 

Power supply

 

Voltage

[V]

120

 

120

 

 

 

 

 

 

 

 

 

Frequency

[Hz]

60

 

60

 

 

 

 

 

 

 

Electric consumption

[W]

1,170

 

1,040

 

 

 

 

[A]

8.30

 

10.50

 

 

 

 

 

 

 

 

 

 

Nozzle

 

[USgal/h]

2.00-30° S

 

3.00-80°S

 

 

 

 

 

 

Pump pressure

 

[psi]

174

 

217

 

 

 

 

 

 

Max static pressure

 

[in WC]

-

 

-

 

 

 

 

 

Recommended max. temp. in the air

[°F]

-

 

-

duct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment of combustion air flap

[in]

a=0.59

 

a=1.00

 

 

 

 

-

 

-

 

 

 

 

 

 

 

 

 

 

Flue diameter

 

[in]

-

 

-

 

 

 

 

 

Compulsory flue draft

[in WC]

-

 

-

 

 

 

 

 

 

Tank capacity

 

[gal]

27.7

 

35.7

 

 

 

 

 

Dimensions, L x W x H

[in]

62.4x27.6x39

 

67.9x27.6x41.2

 

 

 

 

 

 

Net Weight

 

[lb]

222

 

246

 

 

 

 

 

 

 

ENERCO GROUP, INC. Direct Fired Portable Heater

3

Operating Instructions and Owner’s Manual

Image 3
Contents Direct Fired Portable Heater General Hazard Warning Mh 4000DF Mh 6000DF General RecommendationsTransport Safety DevicesOperation Stopping the HeaterColumn Intentionally Left Blank MaintenanceTroubleshooting Wiring Diagram 6000 Series Models Drawing Legend Fuse Control Transformer H.V Room ThermostatOverheat Thermostat Relays 61 62 HeaterStock No 4000 6000 Description 4000DF and 6000DF Series Direct-Fired Portable Heater4000DF 6000DF Safe place for future reference. Do not allow Produit le acheté avez vous qui de détaillant du 0001-251-800 au’œuvre Tiré-Direct Portatif Chauffage 6000DF and 4000DF 6000DF TiréRelais Transformateur ’ambiace thermostat Prise 20A Fusible Models Series 6000 and 4000 Diagram WiringVentilateur Thermostat Electrovanne Securite de Coffret Surchauffe de ThermostatGicleur le changer faut le s’il ou Nettoyer Solutions ET Causes Fonctionnement DE AnomaliesDeplacement ET Transport Blanc LE Quitté Intentionnellement a Colonne LAEntretien 4000DF Securite DE Dispositifs6000DF mh 4000DF mh Generales RecommandationsMarche EN Mise 6000DF hs 4000DF hsOpération Parties de listeConnexions de schémas Sécurité de ArtificesPortatif Chauffage Tiré Direct

4000DF, 6000DF specifications

The Enerco 4000DF and 6000DF are cutting-edge portable heaters designed for versatility, efficiency, and performance, particularly in construction, outdoor, and industrial settings. These units offer robust heating capabilities, making them ideal for jobs that require reliable warmth in challenging environments.

One of the main features of the Enerco 4000DF and 6000DF is their high-output heating capacity. The 4000DF can generate up to 4,000 BTUs, while the 6000DF delivers an impressive 6,000 BTUs. This makes both models suitable for a variety of applications, from heating small workshops to larger construction sites. Their ability to produce substantial heat quickly ensures that work can continue smoothly even in cold weather.

Both models are built with safety in mind, featuring an automatic shut-off system that activates if the unit tips over or overheats. This important safety feature helps to prevent accidents and ensures peace of mind for users working in dynamic environments. Additionally, the heaters are designed to operate quietly, minimizing noise distraction while maintaining a comfortable atmosphere.

The Enerco 4000DF and 6000DF utilize advanced heating technologies that enhance their performance. These forced air heaters incorporate a powerful fan system that efficiently circulates hot air throughout the space. This feature not only increases heating efficiency but also ensures that the warmth reaches every corner, creating a consistent and comfortable environment.

Portability is another significant characteristic of these models. They are equipped with durable wheels and a sturdy handle, allowing for easy maneuverability from one location to another. This mobility is crucial for professionals who require flexibility in their heating solutions. The compact design means they can fit in tight spaces, making them practical for various settings.

In terms of fuel efficiency, both models operate on propane, providing an economical and effective heating solution. The propane system ensures that fuel is consumed optimally, allowing users to enjoy extended operating times without the need for frequent refills.

In summary, the Enerco 4000DF and 6000DF stand out as reliable heating units with their high output, safety features, advanced heating technology, portability, and fuel efficiency. These heaters are designed for professionals who need a dependable source of heat in demanding conditions, making them an excellent choice for anyone looking to maintain productivity in colder environments.