Enerco MH42T Trouble Shooting MR. Heater Appliance, Problem Possible Cause Solution

Page 7

7.SHUTDOWN AND STORAGE INSTRUCTIONS

A.The bulk propane tank “on-off” valve should ALWAYS be completely turned “OFF” when the heater is not in use.

B.When shutting off the heater, turn the regulator knob on the heater to “OFF” (clockwise). (See Figure 4)

C.CAUTION: After turning unit off, heater will remain extremely hot. Allow at least 15 minutes for cooling before handling and storing. Detach heater from bulk tank before handling and storage. REMEMBER – POL fitting is a left-hand thread.

D.HEATER STORAGE: Always remove the propane cylinder from the heater when not in use. Always store propane cylinders in a cool, well ventilated place away from any flame or heat and in a location not used for habitation. DO NOT STORE PROPANE TANK WITHIN 60 FT. OF OPEN FLAME OR HEAT.

E.See Figure 6 for spare parts list.

TROUBLE SHOOTING

MR. HEATER APPLIANCE

The chart assumes that the proper gas and gas pressure is available to the heater. The chart also assumes that the heater is used in accordance with Mr. Heater installation and operating instructions.

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

 

Burners will not light

Propane tank turned off

Open tank valve

 

Propane tank empty

Get tank filled

 

Heater regulator not turned on

Turn valve to medium position

 

Safety Shutoff plunger not depressed

Depress S/S valve while lighting

 

Air in manifold or hose or propane tank

Purge air from unit

 

 

 

 

Hear gas but burners will

Air in propane tank

Return tank to dealer to purge air

not light (hissing)

Defective regulator

Replace

 

Partially plugged orifice

Clean or replace

 

 

 

 

Burner lights, turns red but

Thermocouple not secure

Secure thermocouple

will not stay lit

Thermocouple out of position

Position tip 3/16” to 3/8” from screen

 

Defective thermocouple

Replace thermocouple

 

Safety shutoff defective

Replace safety shutoff

 

 

 

 

Blue flame at top of

Out of storage

Clean all openings with H.P. air

heater screen

Defective regulator

Replace regulator

 

 

 

 

Blue flame only – never gets red

Something in Venturi

Clean venturi tube with wire

 

Orifice partially plugged

H.P. air clean out venturi/orifices

 

Screen plugged up

 

 

 

 

 

 

Connection at propane tank

“O-Ring” on POL missing or defective

Replace “O” ring or POL

leaking gas after securing

Valve seat on cylinder worn

Return to dealer

 

 

 

 

Heater emits high pitched sound

Heater warming up

No Danger – heater warming up.

 

 

Sound will stop in 1-3 minutes

 

 

 

 

If satisfactory results cannot be obtained after performing any of the above procedures,

Please call Mr. Heater’s Customer Care Center at 1-800-251-0001. Thank you.

Mr. Heater Gas-Fired Infra-Red Portable Heater

7

Operating Instructions and Owner’s Manual

Image 7
Contents Model MH42T MH42TGeneral Hazard Warning ContentsLP Cylinder HOOK-UP InformationGeneral Information Odor Fade WarningFor Safe Operation Cooking do not USE this Heater for Cooking Assembly ProcedureVentilation Lighting InstructionsREF.# ITEM# Description ALL Warranty Claims Require Proof of PurchaseProblem Possible Cause Solution Trouble Shooting MR. Heater ApplianceLimited Warranty For Information Regarding ServiceParts Ordering Information