Enerco HS35FA, MH35FA owner manual Operating Instructions, Servicing

Page 5

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION

1.Check the heater for possible shipping damage. If any is found, immediately notify the factory.

2.Follow all of the "Precautions".

3.Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench.

4.Connect the hose to the heater by rotating the hose fitting clockwise.

5.Securely tighten all gas connections.

6.Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.

7.Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.

8.When using an extension cord, make certain that it is a 3-wire (grounded) cord of proper wire size, minimum length of 6 ft (1.83m).

START

1.THE HEATER POWER CORD MUST BE CONNECTED TO A GROUNDED 115V, 60HZ, 1Ø POWER SOURCE BEFORE HEATER IGNITION and always allow heater fan (blower) to run for 20 seconds to purge fuel.

2.Open propane supply valve on propane tank slowly. Note: If not opened slowly, excess-flow check valve on propane tank will

stop gas flow. If this happens, close propane supply valve and open again slowly. Wait 15 seconds before Step 3.

3.Push and hold automatic control valve button. Push piezo ignitor button repeatedly until the burner lights.

4.After the burner lights, keep the gas valve button depressed for 30 seconds then release and the heater will continue to operate.

WARNING: Be sure motor and fan are running before pushing in automatic control valve button. Flames could flash outside heater or internal damage to heater may result if motor and fan are not running.

STOP

1.Securely close valve on the propane cylinder.

2.Continue to operate heater until all fuel in the hose has burned.

3.Unplug the power cord.

CAUTION: Always shut off fuel supply before disconnecting electrical power.

RESTART AFTER SAFETY SHUTDOWN

1.Securely close valve at propane cylinder. Unplug power cord.

2.Wait 5 minutes.

3.Restart following "START" procedure.

MAINTENANCE AND STORAGE

1.The heater should be inspected before each use, and at least annually by a qualified person.

2.Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.

3.Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.

4.When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

*The flame is contained within the heater.

*The flame is essentially blue with perhaps some yellow tipping.

*There is no strong disagreeable odor, eye burning or other physical discomfort.

*There is no smoke or soot internal or external to the heater.

*There are no unplanned or unexplained shut downs of the heater.

The parts lists and exploded view show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be set as shown in "specifications". If there is any uncertainty about the regulator setting, have it checked.

A heater which is not working right must be repaired, but only by a trained, experienced service person.

In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and labor.

Enerco Group, Inc. Forced Air Propane Construction Heater

5

Operating Instructions and Owner’s Manual

Image 5
Contents MR. Heater General Hazard Warning ContentsSpecifications Safety Precautions Operating PrecautionsOdor Fading no Odor Detected Odor Fade WarningFuel GAS Odor Servicing Operating InstructionsForced Air Propane Construction Heater Model #35FA Btus PER Hour Required WarrantySize and Capacity of Propane Cylinders Required Parts Ordering Information Limited Warranty
Related manuals
Manual 16 pages 47.5 Kb Manual 1 pages 60.56 Kb

HS35FA, MH35FA specifications

The Enerco MH35FA and MH35LPTS are robust and versatile forced air heaters designed to provide efficient heating solutions for both residential and commercial applications. Recognized for their reliability, these heaters are particularly favored in construction sites, workshops, and warehouses where temporary heating is essential during cold weather.

One of the main features of the Enerco MH35FA is its powerful heating capability. It can deliver up to 35,000 BTUs, making it effective in heating large spaces quickly. This model operates on propane, ensuring high energy efficiency, and can run for extended periods without interruption. The MH35FA is also equipped with a durable housing and components, enabling it to withstand harsh working conditions.

The MH35LPTS offers similar heating capabilities but is distinguished by its portability. This model comes with a built-in handle and lightweight construction, making it easy to move from one location to another. This feature is particularly useful for contractors who need to transport heaters between job sites. Both models are designed with safety in mind; they include features such as automatic shut-off mechanisms that activate in case of overheating or flame outages, providing peace of mind for users.

Equipped with advanced heating technologies, the Enerco heaters utilize a fan-driven operation that circulates warm air throughout the space effectively. The adjustable heat settings allow users to customize the temperature according to their specific needs, providing optimal comfort and efficiency. The heaters are also designed to be easy to operate, featuring simple controls that can be adjusted even while wearing gloves.

In terms of specifications, both models have a fuel consumption rate that makes them economical choices for long-term heating needs. They are compatible with standard propane tanks, allowing for easy refueling and reduced downtime. The low-maintenance design of Enerco heaters ensures they can operate reliably over multiple seasons with minimal upkeep.

Overall, the Enerco MH35FA and MH35LPTS stand out in the market for their combination of power, efficiency, and user-friendly features. Ideal for a variety of heating applications, these forced air heaters continue to be a popular choice for anyone seeking a dependable and effective heating solution.