IMPORTANT
Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS
heater exhausts hot air and the combustion products into the room, while those with indirect combustion are fitted with a flue to take the fumes away through the chimney.
Always follow local ordinances and codes when using this heater:
•Read and follow this owner’s manual before using the heater.
•
content.
•
materials (the minimum distance must be 6 ft.).
•
•
to the heater requirements. Direct combustion heaters should only be used in well vented areas in order to avoid carbon monoxide poisoning.
•Never block air inlet (rear) or air outlet (front).
•In case of very low temperatures add kerosene to the heating oil.
•Make sure heater is always under surveillance and keep children and animals away from it;
•Before starting the heater always check free rotation of ventilator fan.
•Unplug heater when not in use.
TECHNICAL SPECIFICATIONS |
| MH3500 DF | MH 6000DF | |||
| HS 3500DF | HS 6000DF | ||||
|
|
|
| |||
|
|
|
|
|
| |
Heat input |
| [kBTU/h] | 360 | 600 | ||
|
|
|
|
|
| |
Air Flow |
| [cfm] | 1795 | 2.800 | ||
|
|
|
|
|
| |
Fuel Type |
|
| ||||
|
|
|
|
|
| |
Heat output |
| [kBTU/h] | - | - | ||
|
|
|
|
|
| |
Fuel consumption |
| [gal/h] | 2..6 | 4.32 | ||
|
|
|
| |||
| [lb/h] | 18.56 | 30.84 | |||
|
|
| ||||
|
|
|
|
|
| |
|
| Phase |
| 1 | 1 | |
|
|
|
|
|
| |
Power supply |
| Voltage | [V] | 120 | 120 | |
|
|
|
|
|
| |
|
| Frequency | [Hz] | 60 | 60 | |
|
|
|
|
|
| |
Electric consumption | [W] | 632 | 1,240 | |||
|
|
| ||||
[A] | 6.00 | 11.10 | ||||
|
|
| ||||
|
|
|
|
| ||
Nozzle |
| [USgal/h] | ||||
|
|
|
|
| ||
Pump pressure |
| [psi] | 174 | 203 | ||
|
|
|
|
| ||
Max static pressure |
| [in WC] | - | - | ||
|
|
|
| |||
Recommended max. temp. in the air | [°F] | - | - | |||
duct |
| |||||
|
|
|
| |||
|
|
|
|
|
| |
Adjustment of combustion air Flap | [in] | a=0.394 | a=0.866 | |||
|
|
| ||||
N° | - | - | ||||
|
|
| ||||
|
|
|
|
| ||
Flue diameter |
| [in] | - | - | ||
|
|
|
| |||
Compulsory Flue draft | [in WC] | - | - | |||
|
|
|
|
| ||
Tank capacity |
| [gal] | 35.6 | 35.6 | ||
|
|
|
| |||
Dimensions, L x W x H | [in] | 56.4x26.38x38.3 | 68.5x28.8x44 | |||
|
|
|
|
| ||
Net Weight |
| [lb] | 153 | 243 | ||
|
|
|
|
|
|
ENERCO GROUP, INC. Direct Fired Portable Heater | 3 | Operating Instructions and Owner’s Manual |