English | Operating Instructions HD 10/25 S USA |
|
|
Suctioning water from an open container
Screw suction hose with filter
(Order no.
Vent the unit before using.
To evacuate air from the unit, unscrew the nozzle and leave the unit running until wa- ter exits with no air bubbles.
Switch off the unit and screw the nozzle back on.
Operating the unit
!Danger!Observe the relative safety regulations when using the unit at filling stations or other
Caution!
Only clean engines in places which have appropriate oil separators (protection of the environment).
Caution!
Only wash animals with the low- pressure fan jet (see "Selecting the type of spray").
Operating with high pressure
The unit is equipped with a pressure switch. The motor only starts up when the lever is re- tracted.
Set the unit switch to "I". The indicator light will go green.
Unlock the
Adjust operating pressure and flow rate
At the lowest flow rate the waste heat from the motor will heat the water to approx. 15 °C.
Selecting the type of spray
The handgun must be closed.
Rotate the housing of the nozzle until the desired symbol corresponds with the mark- ing.
Select pencil jet or fan jet by contactless changeover:
rotate the spray lance, which is pointing down at an angle of approx. 45°, to the left or right.
Explanation of the symbols
for particularly stubborn accumu- lation of grime.
dirt accumulation over a large surface.
Low-pressure fan jet (CHEM)
for operation with detergent or for cleaning at low pressure.