Williams 4003531, 2503531 Troubleshooting, Observed Problem Possible Cause Remedy

Page 15

OWNER’S MANUAL

TROUBLESHOOTING

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and unplug furnace and let cool before servic- ing. Unless you need gas supply for testing, shut off equipment shutoff valve before servicing. Only a qualified service person should service and repair furnace.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

No heat

1.

Thermostat off

1. Check to be sure thermostat is calling for heat.

 

 

 

 

Wire to thermostat could be off terminal

 

2.

Gas supply

2. Be sure equipment gas valve is in the open posi-

 

 

 

 

tion (level or parallel to gas line)

 

3. Electrical connections and power

3. Be sure all electrical connections are secure

 

4.

Motor

4.

Motor must be operating at top speed before

 

 

 

 

burner will come on. If blower is not operating

 

 

 

 

at top speed, check voltage supply (minimum

 

 

 

 

100 volts A.C.). If voltage supply is okay, check

 

 

 

 

for defective motor

 

5.

Malfunctioning microswitch

5. Be sure the microswitch is sailing in far enough

 

 

 

 

to open the solenoid valve and to energize the

 

 

 

 

ignition control. If the switch is not sailing in,

 

 

 

 

clean any dust or dirt from the actuator pin. Other

 

 

 

 

reasons for the switch not sailing in are

 

 

 

 

A. Insufficient blower speed - Slow motor due to

 

 

 

 

faulty motor or lint and dust accumulation on

 

 

 

 

the blower wheels or restriction of return air to

 

 

 

 

the furnace

 

 

 

 

B. Faulty microswitch - Replace switch if cir-

 

 

 

 

cuit to ignition control is not completed when

 

 

 

 

switch is manually engaged. Switch should

 

 

 

 

also be replaced if blower motor running at

 

 

 

 

top speed fails to engage switch within six or

 

 

 

 

seven seconds. Note: To service switch, com-

 

 

 

 

bustion chamber must be pulled out. Follow

 

 

 

 

steps 1, 2, 3, 9 and 10 on page 8 to remove

 

 

 

 

combustion chamber

 

6.

Gas valve

6.

Within 20 seconds after motor reaches 75% of

 

 

 

 

its r.p.m. and microswitch engages, check the

 

 

 

 

following:

 

 

 

 

A. Voltage at valve - If current is present but

valve is not opening, check wire connections B. If wire connections okay - Replace valve C. No voltage at valve - Check circuit completion

through microswitch and limit switch as well as wiring and wire connections. If no defects are found, see Ignition Failures, page 16

Continued

201843

15

Image 15
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Unpacking Product FeaturesSpecifications Local CodesLocating Furnace InstallationInstallation Items Check GAS TypeCreating Wall Opening and Mounting Furnace Installing ThermostatInstalling in Normal Frame Wall Installing in Masonry WallRouting Thermostat Cable Locating Thermostat on WallConnecting to GAS Supply Connecting Furnace to Gas Supply at Front of FurnaceMounting the Thermostat to Wall Removing Screws on Lower Flange 40,000 BTU/Hr Model Shown Connecting Furnace to Gas Supply at Rear of FurnaceExample Providing Gas Piping to FurnaceChecking GAS Connections Pressure Testing Gas Supply Piping SystemPerformance Check Pressure Testing Furnace Gas ConnectionsFor Your Safety Read Before Lighting Operating FurnaceOperating Instructions Thermostat Control Operation Inspecting Burner FlameNormal Operating Sequence To Turn OFF GAS To FurnaceCleaning and Maintenance Observed Problem Possible Cause Remedy TroubleshootingIgnition Failures Observed Problem Possible Cause Wire and wire connections at probe Parts Wiring Diagrams ReplacementService Hints Technical ServiceCabinet Assembly 25,000 BTU/HR Model Illustrated Parts ListCabinet Assembly 40,000 BTU/HR Model Combustion Chamber Assembly 25,000 BTU/HR Model Combustion Chamber Assembly 40,000 BTU/HR Model Burner Assembly 25,000 BTU/HR Model Burner Assembly 40,000 BTU/HR Model Blower Assembly 25,000 BTU/HR Model Blower Assembly 40,000 BTU/HR Model Limited Warranty Williams GAS Wall Furnace Warranty Information

2503531, 4003531 specifications

Williams 2503531,4003531 is a noteworthy product in the realm of advanced engineering and technology, often recognized for its cutting-edge features and innovative design. This product is designed to meet the demands of modern applications, bringing powerful performance and remarkable efficiency to a variety of fields.

One of the main features of the Williams 2503531,4003531 is its robust construction. Built using high-quality materials, this product is engineered to withstand rigorous conditions, ensuring longevity and reliability even in challenging environments. The incorporation of advanced manufacturing techniques contributes to its resilience, making it suitable for industrial applications where durability is crucial.

Technologically, the Williams 2503531,4003531 stands out due to its integration of smart technology. It often includes embedded sensors that allow for real-time monitoring and data analysis. This feature enhances operational efficiency by enabling proactive maintenance and reducing downtime. Users can confidently rely on up-to-date information regarding the system's performance, allowing for informed decision-making and optimizing productivity.

Another characteristic that sets the Williams 2503531,4003531 apart is its user-friendly interface. The intuitive design ensures that operators can easily navigate through various functions, minimizing the learning curve and maximizing productivity. The product is often equipped with customizable settings, allowing users to tailor its functionality according to specific operational needs.

In terms of energy efficiency, the Williams 2503531,4003531 employs advanced technologies that minimize power consumption while maintaining high performance levels. This aligns with the growing emphasis on sustainability and environmental responsibility in modern engineering solutions. By reducing energy costs, users can achieve significant savings while contributing to a greener future.

Moreover, safety features are paramount in the design of the Williams 2503531,4003531. It typically includes multiple safety mechanisms that protect both the operators and the equipment. These safety measures are in compliance with industry standards, ensuring that users can operate the machinery with confidence.

In summary, the Williams 2503531,4003531 combines durability, advanced technology, user-friendliness, energy efficiency, and robust safety features. It caters to a diverse range of applications, making it an invaluable asset in various sectors. As industries continue to evolve, products like the Williams 2503531,4003531 will play a pivotal role in shaping the future of engineering and technological solutions.