Bryant 374RAN Performing Routine Maintenance, Filtering OUT Trouble, Furnace AIR Filter Table

Page 6

2.Turn off all electrical power to the furnace. (See Fig. 9.)

9

3.Close oil supply valve. (See Fig. 10).

10

4.If applicable, turn off water sup- ply to humidifier.

5.If furnace blower will be neces- sary for cooling system, remem- ber to turn electric power back on when needed for air condi- tioning.

6.If furnace is being shut down be- cause of a malfunction, call your dealer as soon as possible.

ALWAYS KEEP MAIN OIL VALVE TURNED OFF IF BURNER IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME.

PERFORMING

ROUTINE

MAINTENANCE

With proper maintenance and care, your furnace will operate economi- cally and dependably. Instructions for basic maintenance follow. How- ever, before beginning maintenance, follow these safety precautions:

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal inju- ry or death.

Turn off all electrical power to furnace before performing any maintenance or service on unit.

11

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury. Although special care has been taken to minimize sharp edges, be extremely careful when handling parts or reaching into the furnace.

FILTERING OUT

TROUBLE

Dirty air filters will cause a loss of airflow in your duct system. When excessive loss of airflow occurs, the furnace may cycle on its safety controls. If this condition is left unattended, the furnace will even- tually lock out. It is recommended that furnace air filters be checked every 3 or 4 weeks and cleaned or replaced as necessary.

6

!CAUTION

UNIT DAMAGE HAZARD Failure to follow this caution may result in reduced unit component life.

Never operate your furnace without the air filters in place. Doing so may damage the furnace blower motor. An ac- cumulation of dust and lint on internal parts of your furnace can cause a loss of efficiency.

The air filter is installed in an ex- ternal filter rack which is provided as standard equipment with furnace.

To inspect, clean, and/or replace air filter, follow these steps:

1.Turn off electrical supply to fur- nace. (See Fig. 11.)

2.Remove filter from external fil- ter rack.

3.Inspect filter. If torn, replace it.

NOTE: If filter has been replaced with an electronic air cleaner (EAC), refer to the EAC Owner’s Manual for maintenance informa- tion.

4.If filter is dirty, it must be re- placed. If your furnace air filter needs to be replaced, be sure to use the same size and type of fil- ter that was originally supplied. Use furnace filter table for filter size and filter rack flange dimen- sions for return air duct.

FURNACE AIR FILTER TABLE

FLANGE

 

 

OPENING

FILTER

 

SIZE

SIZE

FILTER

(IN.)

(IN.)

TYPE

 

 

 

 

Model Size 105

 

 

 

 

 

16 X 24 X 1

 

15 X 23

or

Disposable

 

16 X 25 X 1

 

 

 

 

 

Model Size 120

 

 

 

 

 

18 X 30 X 1

 

19 X 29

or

Disposable

 

20 X 30 X 1

 

 

 

 

If you have replaced a disposable filter with a permanent washable filter, it may be cleaned if it is dirty.

Image 6
Contents Model 374RAN OIL Furnace Welcome to a NEW Generation of Comfort Installation Data SPLIT-SYSTEMAccessories Model 374RAN Multipoise FurnaceFurnace Components Considerations SafetyImportant Facts Starting YourShutting Down Your Furnace Steps for Starting Your FurnaceElectrical Shock HAZ- ARD High Voltage AT Igniter Performing Routine Maintenance Filtering OUT TroubleFurnace AIR Filter Table CHECK-UP Checklist Beforeyou Request a Service CallCancels New OM16-16 Catalog No 12-04

374RAN specifications

The Bryant 374RAN is a cutting-edge air conditioning unit designed to provide efficient cooling solutions for residential and small commercial spaces. Esteemed for its reliability and advanced technology, the Bryant 374RAN represents a strong choice for homeowners seeking comfort and energy efficiency.

One of the standout features of the Bryant 374RAN is its SEER rating, which stands at an impressive level, making it one of the more energy-efficient models in the market. This Seasonal Energy Efficiency Ratio (SEER) not only helps reduce energy consumption but also lowers utility bills, making it an eco-friendly choice. The unit is equipped with a variable-speed compressor, which allows for precise temperature control and better humidity management, enhancing indoor comfort throughout the season.

The Bryant 374RAN utilizes Silver series technology that ensures durability and performance. Its components are designed and tested for longevity, providing peace of mind to homeowners investing in this system. Additionally, Bryant incorporates a sound-dampening system with acoustic insulation, ensuring that the operation of the unit remains quiet, which is important for residential settings.

For those looking for seamless integration with smart home systems, the Bryant 374RAN offers excellent compatibility. It can be paired with a smart thermostat, allowing users to remotely monitor and control their home’s cooling from anywhere. This smart technology optimizes energy use, adjusts settings based on occupancy, and provides alerts for maintenance needs.

In terms of installation and maintenance, the Bryant 374RAN comes with straightforward guidelines, ensuring that users can easily have it integrated into their homes. The unit features a top discharge design, allowing for better airflow and heat dissipation, which contributes to its efficiency. The cabinet is constructed from corrosion-resistant materials, enhancing its longevity while maintaining a sleek aesthetic.

Overall, the Bryant 374RAN is a feature-rich air conditioning solution that prioritizes energy efficiency, advanced technology, and durable construction. Its commitment to performance makes it a reliable choice for consumers, ensuring comfortable indoor climates regardless of external weather conditions. The combination of cost-effectiveness, ease of use, and integration capabilities positions the Bryant 374RAN as a preferred option for modern climate control needs.