Bryant 185248 manual Beforeyou Request a Service Call, For Insufficient Airflow

Page 7

Check flue and secondary tube pas- sage ways including chimney — clean if necessary.

Change oil filter.

Change nozzle.

Check and adjust combustion and draft.

Inspect all vent piping inside struc- ture for deterioration and vent termi- nations outside the structure for blockage.

Check oil pipes leading to and inside of your furnace for leaks.

Inspect and clean the blower motor and wheel.

Inspect and change or clean air fil- ter if necessary.

Inspect all supply- and return-air ducts for obstructions, air leaks, and insulation. Remedy any problem when necessary.

Inspect the return-air duct connec- tions at the furnace to ensure it is physically sound, sealed to the fur- nace casing, and terminates outside the space containing the furnace.

Inspect electrical wiring, connec-

tions, and components for loose connections.

Examine the physical support of the furnace. Support should be sound with no cracks, sagging, gaps, etc. around the base.

Check furnace for any obvious signs of deterioration.

BEFOREYOU REQUEST A SERVICE CALL

If your furnace is not operating or not performing properly, you may save the expense of a service call by checking a few things yourself before calling for service.

FOR INSUFFICIENT AIRFLOW:

Check for dirty air filters.

Check for blocked return-air or supply-air grilles throughout your home. Ensure they are open and unobstructed.

If problem still exists, call your dealer for service.

IF FURNACE FAILS TO OPERATE:

Follow this checklist step by step, advancing to the next step only if furnace fails to start.

Check thermostat for proper tem- perature. Is thermostat set above room temperature?

Is thermostat set on HEAT?

Check fuses and circuit breakers. Is electrical supply on?

Is valve in oil supply pipe in open position?

Is the ignition control on the burn- er not in lockout? The red button on top of the control must be depressed for 3 sec in order to reset the control.

Check for obstructions around the vent termination.

If furnace still fails to operate, call your service representative. For your convenience, record furnace product and serial numbers on page 2. Should you ever require service, you will have ready access to the infor- mation needed by your service rep- resentative.

7

Image 7
Contents Model 369RAN OIL Furnace Model 369RAN Multipoise Furnace Installation DataAccessories Welcome to a NEW Generation of ComfortFurnace Components Starting Your Furnace Safety ConsiderationsFor Your Safety Important FactsSteps for Starting Your Furnace Shutting Down Your FurnaceFurnace AIR Filter Table Performing Routine MaintenanceCHECK-UP Checklist Filtering OUT TroubleFor Insufficient Airflow Beforeyou Request a Service CallCancels New OM16-12 Catalog No 11-00

185248 specifications

Bryant 185248 is a modern technological marvel that epitomizes efficiency and performance in the HVAC industry. This unit is designed for both residential and commercial applications, offering a comprehensive solution for heating and cooling needs. One of the standout features of Bryant 185248 is its impressive energy efficiency ratings, which help to lower energy costs while providing optimal comfort. The unit achieves high SEER (Seasonal Energy Efficiency Ratio) and AFUE (Annual Fuel Utilization Efficiency) ratings, making it an environmentally friendly choice that complies with modern energy standards.

Equipped with advanced inverter technology, the Bryant 185248 operates quietly while delivering precise temperature control. The inverter-driven compressor adjusts its speed to match the cooling or heating load, ensuring efficient operation without the constant on-and-off cycling of traditional units. This not only enhances comfort but also extends the lifespan of the equipment.

The user-friendly interface of Bryant 185248 allows for easy operation and monitoring. Homeowners can customize their comfort settings with a programmable thermostat that offers remote access, enabling adjustments from anywhere. The integration of smart home technology is another highlight, as the unit can connect seamlessly with various home automation systems.

In terms of reliability, Bryant is known for its robust construction and durability, which are evident in the design of the 185248. The unit features corrosion-resistant components, ensuring it withstands harsh weather conditions and maintains peak performance over time. Additionally, Bryant offers a comprehensive warranty, providing peace of mind to users.

The Bryant 185248 also stands out for its environmentally friendly refrigerant, which aligns with global efforts to reduce greenhouse gas emissions. This commitment to sustainability reflects the growing demand for eco-conscious products in the HVAC market.

Overall, the Bryant 185248 is designed with cutting-edge technology, energy efficiency, and user convenience in mind. Whether for residential or commercial use, this unit is a versatile choice that delivers reliable performance, ensuring comfortable indoor climates year-round. Its combination of innovative features and solid construction make it a worthy investment for anyone looking to upgrade their heating and cooling systems.