User’s Information
The following warning complies with State of California law, Proposition 65.
▲! WARNING
THIS PRODUCT CONTAINS FIBERGLASS WOOL INSULATION!
Fiberglass dust and ceramic fibers are believed by the State of California to cause cancer through inhalation. Glasswool fibers may also cause respiratory, skin, or eye irritation.
PRECAUTIONARY MEASURES | FIRST AID MEASURES | ||
● Avoid breathing fiberglass dust. | Eye Contact | – Flush eyes with water to remove dust. | |
● Use a NIOSH approved dust/mist respirator. |
| If symptoms persist, seek medical | |
| attention. | ||
● Avoid contact with the skin or eyes. Wear |
| ||
Skin Contact | – Wash affected areas gently with soap | ||
| and warm water after handling. | ||
● Wash clothes separately from other clothing: rinse |
| ||
|
| ||
washer thoroughly. |
|
| |
● Operations such as sawing, blowing, |
|
| |
spraying may generate fiber concentrations requiring |
|
| |
additional respiratory protection. Use the appropriate |
|
| |
NIOSH approved respirator in these situations. |
|
| |
|
|
|
▲! WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow the installation and operation instructions for the venting system’s operation could result in carbon monoxide poisoning or death.
Regular Dealer Maintenance
Never stop the cooling system by shutting off the main power.
If the main power to your air conditioner is ever disconnected for more than three hours, turn off the thermostat. Then wait for at least three more hours after the power has been restored before turning the thermostat back on. Failure to follow this procedure could result in damage to your air conditioning system.
1.GENERAL INSPECTION – Examine the furnace installation for the following items:
a.All flue product carrying areas external to the furnace (i.e. chimney, vent connector) are clear and free of obstruction.
b.The vent connector is in place, slopes upward and is physically sound without holes or excessive corrosion.
c.The return air duct connection(s) is physically sound, is sealed to the furnace and terminates outside the space containing the furnace.
d.The physical support of the furnace should be sound without sagging, cracks, gaps, etc., around the base so as to provide a seal between the support and the base.
e.There are no obvious signs of deterioration of the furnace.
The following warning complies with State of California law, Proposition 65.
▲! WARNING
Hazardous Gases!
Exposure to fuel substances or
2.BLOWERS – The blower size and speed determine the air volume delivered by the furnace. The blower motor bearings are factory lubricated and under normal operating conditions usually do not require servicing. Annual cleaning of the blower wheel and housing is recommended for maximum air output, and this must be performed only by a qualified servicer or service agency.
▲! WARNING
Unit is equipped with a blower door switch which cuts power to blower and gas valve causing shutdown when door is removed. Unit must not be altered to allow opera- tion with the blower door removed. Operation with doors removed or ajar can permit the escape of dangerous fumes. All panels must be securely closed at all times for safe operation of the furnace.
7 |