Ducane RGE13 warranty Blower Performance

Page 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

RGE13

Package Gas / Electric

 

 

 

seer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

BTUH

 

SEER

 

EER

 

 

 

 

Input

Output

Efficiency

Temp

 

 

 

 

 

 

 

S/T

 

CFM

Rise

 

 

 

 

 

 

 

 

 

 

 

BTUH

BTUH

 

AFUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A24050(L)P

22,800

13.0

11.0

0.73

 

800

50,000

 

40,000

 

 

80%

 

30 - 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A24075(L)P

75,000

 

60,000

 

 

35 - 65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A30050(L)P

28,000

13.0

11.0

0.74

 

1000

50,000

 

40,000

 

 

80%

 

30 - 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A30075(L)P

75,000

 

60,000

 

 

35 - 65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A36075(L)P

34,000

13.0

11.0

0.71

 

1200

75,000

 

60,000

 

 

80%

 

35 - 65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A36100P

100,000

 

80,000

 

 

45 - 75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A42075(L)P

40,000

13.0

11.0

0.75

 

1400

75,000

 

60,000

 

 

80%

 

30 - 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A42100(L)P

100,000

 

80,000

 

 

40 - 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A48100(L)P

46,000

13.0

11.0

0.75

 

1600

100,000

 

80,000

 

 

80%

 

40 - 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A48125P

125,000

 

100,000

 

 

45 - 75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A60100(L)P

56,000

13.0

11.0

0.72

 

1800

100,000

 

80,000

 

 

80%

 

40 - 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A60125P

125,000

 

100,000

 

 

45 - 75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blower Performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blower

 

 

 

CFM @ ext. Static Pressure in in. wc without filter, dry coil

 

 

 

 

Model

 

Tap*

 

0.1

 

0.2

 

0.3

 

0.4

0.5

 

0.6

 

 

0.7

 

 

0.8

 

 

 

 

 

(1 - 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

500

 

480

 

420

 

340

290

 

240

 

 

---

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A24***(L)P

 

2

 

830

 

790

 

760

 

710

640

 

600

 

 

560

 

 

520

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

950

 

920

 

890

 

850

810

 

740

 

 

700

 

 

660

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

630

 

550

 

470

 

420

380

 

320

 

 

---

 

 

---

 

 

 

RGE13A30***(L)P

 

2

 

1020

 

990

 

960

 

920

890

 

850

 

 

790

 

 

740

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

1100

 

1060

 

1030

 

1010

990

 

950

 

 

900

 

 

840

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

760

 

680

 

600

 

550

490

 

---

 

 

---

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A36***(L)P

 

2

 

1250

 

1210

 

1180

 

1130

1090

 

1060

 

 

1010

 

960

 

 

 

 

 

3

 

1370

 

1330

 

1280

 

1250

1210

 

1170

 

 

1120

 

1040

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

860

 

780

 

710

 

660

600

 

560

 

 

---

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A42***(L)P

 

2

 

1460

 

1400

 

1340

 

1280

1230

 

1180

 

 

1140

 

1100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

1600

 

1560

 

1500

 

1450

1400

 

1320

 

 

1230

 

1150

 

 

 

 

 

1

 

970

 

890

 

820

 

780

740

 

680

 

 

---

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGE13A48***(L)P

 

2

 

1680

 

1640

 

1590

 

1540

1450

 

1330

 

 

1260

 

1180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

1890

 

1820

 

1730

 

1620

1540

 

1430

 

 

1300

 

1210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1200

 

1130

 

1070

 

990

930

 

860

 

 

-

 

 

-

 

 

 

RGE13A60***(L)P

 

2

 

1870

 

1840

 

1800

 

1760

1700

 

1650

 

 

1600

 

1550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

2010

 

1970

 

1930

 

1890

1850

 

1810

 

 

1760

 

1700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Add .10 Duct Static for Downflow CFM

* Tap 1

- Fan Only

Taps 4 & 5 designed for Heating mid point temperature rise @:

 

Tap 2

- Low Static Cooling

Tap 4 - Nominal .2 ESP

 

Tap 3

- High Static Cooling

Tap 5 - Nominal .5 ESP

- Page 3 -

Image 3
Contents Heat Exchanger InstallationWarranty Refrigerant SystemElectrical and Physical Data Model Number GuideBlower Performance PerformanceCooling Performance Extended Ratings 115DB/WB Minimum clearances to combustible material DimensionsSound Ratings Accessories Field Provided Filter DimensionsSound

RGE13 specifications

The Ducane RGE13 is a premium gas grill designed for outdoor cooking enthusiasts who value both performance and aesthetics. Noteworthy for its robust construction and advanced features, the RGE13 excels in delivering high-quality grilling experiences. Its stainless steel body not only adds to the grill's sleek and modern look but also ensures durability and resistance to the elements.

One of the main features of the Ducane RGE13 is its powerful grilling system, which incorporates four stainless steel burners. These burners provide a total output of 48,000 BTUs, allowing for intense heat that is crucial for searing meats and achieving those coveted grill marks. The burners are designed for even heat distribution, eliminating cold spots and ensuring perfectly cooked meals every time.

The RGE13 includes an integrated ignition system that simplifies the lighting process. With a push of a button, chefs can ignite all burners within seconds, making it convenient for spontaneous grilling sessions. Additionally, the grill features a built-in thermometer, allowing users to monitor temperatures accurately without having to lift the lid frequently, which can cause heat loss.

Another standout characteristic of the Ducane RGE13 is its spacious cooking area. With a total grilling space of 665 square inches, it accommodates large cuts of meat, multiple burgers, or an array of vegetables simultaneously. The porcelain-coated cast iron grates provide excellent heat retention and give food beautiful grill marks, while the removable grease tray simplifies cleanup and maintenance.

Furthermore, the Ducane RGE13 incorporates a side burner, offering flexibility to prepare side dishes or sauces while grilling. This adds versatility for barbecue lovers, enabling them to create complete meals in one cooking session. The addition of shelves on either side increases workspace for food prep and utensil storage.

In terms of safety, the RGE13 comes equipped with sturdy ignition controls that are conveniently located and designed for easy access. The grill's wheels provide mobility, allowing users to reposition it effortlessly in their outdoor spaces.

Overall, the Ducane RGE13 stands out as an outstanding choice for grill enthusiasts who prioritize quality, performance, and convenience in their outdoor cooking experiences. With its powerful burners, spacious cooking area, and thoughtful design features, this grill caters to both casual cooks and culinary aficionados alike. Whether hosting a summer barbecue or preparing a simple weeknight meal, the Ducane RGE13 promises to deliver delicious results every time.