INSTALLATION COMPONENTS

The following items are available for use in the installation of this appliance.

Firestop Spacer (30° )

63L30

F8FS30

Firestop Spacer (30° )

63L32

F8FS30-2**

 

 

 

Offset/ Return

 

 

Package (30° )

63L22

FTF8-ES30

Stabilizer

63L25

FTF8-S4

Unit Mounted

 

 

Blower Switch Kit

91L48

FUBSK

 

 

 

Shipping Weight

 

175 lbs.

Chimney Section

63L10

FTF8-12

 

63L13

FTF8-18

 

63L14

FTF8-36

 

63L15

FTF8-48

Canadian

62L92

FTF8-18C

Chimney Section

62L93

FTF8-36C

 

63L38

F8F6

Flashing

63L39

F8F12

 

 

 

Round Termination

63L42

FTF8-CTD

Storm Collar

63L59

FSC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination

 

 

Offset/Return Elbow

63L28

FTF8-OR15

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

(FBK-200 Models Only)

Forced Air Blower Kits

 

 

-Single Speed

80L84

FBK-100

-Variable Speed

80L85

FBK-200

 

 

 

Outside Combustion Air Kits

 

(with duct)

FOAK

(without duct)

FOAK-LD

 

 

Firestop Spacer (Flat)

63L29

F8FS

Firestop Spacer (Flat)

63L31

F8FS-2**

 

 

 

Cold Climate Kits

63L61

FTF8-CCK1-LD**

**Note: 2" clearance required for Canadian Installation - as applicable.

19

Image 19
Contents Wood Burning Fireplaces P/N 700,040M REV. a 02/2008 Retain These Instructions For Future ReferenceOTL Report No -F-43-2 Table of Contents Clearances and Height Requirements Typical InstallationPrecautions IntroductionBefore You Start Assembly OutlineChimney Height Chase EnclosureClearances Assembly StepsPRE-INSTALLATION Notes Installing the FireplaceRight Side Fireplace SpecificationsFront BC Model Shown Left SideFraming Specifications Room Above Firestop Spacer Attic Above Installing the Chimney SystemFor Canadian Installations Proceed with Steps 5 through 8d Nail Or Equivalent FastenerFor Canada Only Or CeilingOpen Attic Space Using a FTF8-CT2 Chase Termination Using a FTF8-CTD Round TerminationUsing a FTF8-CTDT Chase Termination Using a FTF8-CT1 Chase TerminationSpecial Offset Instructions TEN Foot Rule SummaryMultiple Terminations FTF8 Chimney Component CalculationsChimney Lengths FTF8 Vertical Elevation ChartOffset Calculations Number Of FTF8Height Offset Elevation ChartOptional Equipment Considerations Installing OffsetsOffset Elbow Assembly Return Elbow AssemblyGas Line Connection Combustion Air KitsVent Free Appliances Mantels and Trim Glass DoorsCold Climate Insulation Fireplace FinishesMethods of Determining Hearth Extension and Wall Shield Hearth Extension DimensionsTL = minimum thickness of listed material RM = rM x TS = 0.05 x 3/4 = Finish to Your TasteSum of all R values is .70 + .10 + + .10 = Value = 1/k = r x thickness of material usedShipping Weight Installation Components700,040M REV. a 02/2008 LHPOrange, CA