Carrier 58CLA manual Before YOU Request Service Call, For Insufficient Airflow

Page 8

Check oil pipes leading to and inside of your furnace for leaks.

Inspect and clean the blower motor and wheel.

Inspect and change or clean air filters if necessary.

Inspect all supply- and return-air ducts for obstruc- tions, air leaks, and insulation. Remedy any problem when necessary.

Inspect the return-air duct connections at the furnace to ensure it is physically sound, sealed to the furnace casing, and terminates outside the space containing the furnace.

Inspect electrical wiring, connections, and compo- nents for loose connections.

Examine the physical support of the furnace. Support should be sound with no cracks, sagging, gaps, etc. around the base.

Check furnace for any obvious signs of deterioration.

BEFORE YOU REQUEST

A SERVICE CALL

If your furnace is not operating or not performing properly, you may save the expense of a service call by checking a few things yourself before calling for service.

FOR INSUFFICIENT AIRFLOW:

• Check for dirty air filters.

Check for blocked return-air or supply-air grilles throughout your home. Ensure they are open and unobstructed.

If problem still exists, call your dealer for service.

IF FURNACE FAILS TO OPERATE:

Follow this checklist step by step, advancing to the next step only if furnace fails to start.

Check thermostat for proper temperature. Is thermo- stat set above room temperature?

Is thermostat set on HEAT?

Check fuses and circuit breakers. Is electrical supply on?

Is valve in oil supply pipe in open position?

Is the ignition control on the burner not in lockout? The red button on top of the control must be depressed for 3 sec in order to reset the control.

Check for obstructions around the vent termination.

If the furnace still fails to operate, call your service rep- resentative. For your convenience, record the furnace product and serial numbers on page 2. Should you ever require service, you will have ready access to the infor- mation needed by your service representative.

TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or the classified section of your local telephone directory under the

“Heating Equipment’’ or “Air Conditioning Contractors & Systems’’ heading for dealer listing by brand name. Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part.

Carrier Corporation Indianapolis, IN 46231

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Copyright 2004 Carrier Corporation

Form: OM58-112

Replaces: OM58-86 Printed in the U.S.A.

6-04

PC 101

Catalog No. 535-80134

Image 8
Contents OIL Furnace 58CLAInstallation Data Model 58CLA LOW-BOY Furnace AccessoriesWelcome to a NEW Generation of Comfort FurnaceFurnace Components Safety Considerations For Your SafetyImportant Facts Starting Your FurnaceSteps for Starting Your Furnace Electrical Shock Hazard High VOLT- AGE AT IgniterFiltering OUT Trouble Performing Routine MaintenanceShutting Down Your Furnace CHECK-UP Checklist Furnace AIR Filter TableBefore YOU Request Service Call For Insufficient Airflow

58CLA specifications

The Carrier 58CLA is a high-efficiency gas furnace known for its advanced technology and reliable performance. Designed to provide exceptional heating and comfort for residential spaces, the 58CLA stands out as a premium choice for homeowners seeking energy efficiency and durability.

One of the defining features of the Carrier 58CLA is its two-stage heating operation. This allows the furnace to operate at a low stage for most of the heating demands, enhancing comfort while consuming less energy. During peak demand periods, the furnace seamlessly transitions to a higher stage, providing optimal warmth without compromising efficiency. This ability to adjust its output based on the heating needs of the home ensures consistent temperatures, reduces energy bills, and increases comfort.

The furnace is equipped with an advanced, ECM (Electronically Commutated Motor) blower motor, which significantly improves airflow consistency and reduces electrical consumption compared to traditional motors. This technology not only enhances efficiency but also contributes to quieter operation. Homeowners will appreciate the reduced noise levels, making the 58CLA a great choice for living environments.

Additionally, the Carrier 58CLA incorporates a durable heat exchanger designed for long-lasting performance. Made of aluminized steel, the heat exchanger ensures efficient heat transfer and reliability over time. Carrier also includes a rust-resistant finish, which protects the furnace from corrosion, enhancing its lifespan.

In terms of installation flexibility, the 58CLA is designed to accommodate various home configurations. It offers both horizontal and vertical venting options, making it compatible with different spaces and layouts. Moreover, the unit's compact design allows for easy placement in smaller mechanical rooms or tight spaces.

Another noteworthy feature is its compatibility with Carrier's Infinity Touch Control, which allows homeowners to have advanced control over their heating system. This smart thermostat can regulate not only the furnace but also integrates with other HVAC components for a comprehensive home comfort solution.

Overall, the Carrier 58CLA gas furnace represents a fusion of efficiency, comfort, and innovative technology. With its two-stage heating, advanced blower motor, durable construction, and installation flexibility, it remains a top choice for those looking to enhance their home's heating system. Whether faced with the chill of winter or maintaining a cozy indoor environment, homeowners can trust the Carrier 58CLA to deliver reliable heating performance year after year.