INTERMITTENT PILOT (IP) MODEL

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot.

Do not try to light the pilot by hand.

B.BEFORE OPERATING smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediatelycallyourgassupplierfromaneighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to slide the gas control knob. Neveruse tools. Force orattempted repairmay result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

GAS FLOW

GAS VALVE SHOWN IN OFF POSITION

HONEYWELL IP SMART VALVE

5.Remove front panel door.

6.Slide gas control switch to "OFF."

7. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8.Slide gas control switch to "ON".

9.Replace front panel door.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions "TO TURN OFF GAS TOAPPLIANCE" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove front panel door.

4.Slide gas control switch to "OFF."

5.Replace front panel door.

Page 12

12427-6-0707

Image 12
Contents Installation Instructions Instructions to Installer Installation on Rugs and TileInstallation in Residential Garages 275 AccessoriesSafety Information for Users of LP-GAS Installation in an Unconfined Space Installation in a Confined SpaceVentilation and Combustion Air Ventilation Air Openings and DuctsQualified Installing Agency Before Installing Consider The Following VentingClearances 102mm Oval In-The-Wall all parts purchase locallyInstalling Optional Side Outlets Installing Optional Rear OutletInstallation of Three-prong Grounding Plug Assembly Installing a New Main Gas CockMethod of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply SystemCleaning Combustion Exchanger Assembly Checking Manifold PressureHigh Altitudes Piezo Pilot Ignitor InstructionsWiring Thermostat InstallationVent Safety Shutoff System Oiling the MotorPilot Flame Adjustment If Electrode Does Not Produce SparkIf Pilot Does Not Light By Any Means If Pilot Does Not Remain On After Releasing KnobFor Your Safety Read Before Lighting For Your Safety Read Before Operating Sequence of Operation IP System Troubleshooting Sequence Part number and description of part coincide Index Part Number Description12427-6-0707 Service Notes Empire Comfort Systems, Inc