Empire Comfort Systems FAW-55SPP installation instructions SOR-1

Page 12

Model No. FAW-55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor. Clearance to combus- tible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes.

4” (102mm) Round (all parts purchase locally except in item 2)

1.Type B-1 round pipe

2.Part No. DV-648, 4” (102mm) oval-to-round flue adapter kit (see accessories)

3.Single story type B-1 gas vents require a baseplate and one pair of ceiling plate spacers.

4.Multi-story type B-1 gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair of fire stop spacers at each successive ceiling level.

4” (102mm) Oval (all parts purchase locally)

1.Type B-1 oval pipe

2.Single story type B01 gas vents require a baseplate and one pair of ceiling plate spacers.

3.Multi-story type B-1 gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair of fire stop spacers at each successive ceiling level.

4” (102mm) Oval In-The-Wall(wall parts purchase locally)

1.Type B-1 oval pipe

2.Type B01 oval elbows

3.Single story type B-1 gas vents require a baseplate and one pair of ceiling plate spacers.

4.Multi-story type B-1 gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair

of fire stop spacers at each successive ceiling level.

Stud space around gas vents must be free of obstructions and building paper.

 

Accessories

Part No.

Description

SOR-1

Register, side outlet, fixed register

SOK-1

Side outlet, 10” (254mm) maximum extension,

 

fixed register

ROK-1

Rear Outlet, 10” (254mm) maximum extension,

 

adjustable register

DV-651

Vent enclosure, 14” (356mm) [for rooms up to 96

 

1/2” (245cm) in height]

DV-655

Vent enclosure, 24” (610mm) [for rooms up to

 

106 1/2” (270.5cm) in height]

DV-666

Vent enclosure, 36” (914mm) [for rooms up to

 

118 1/2” (301cm) in height]

DV-648

4” (102mm) Oval-to-Round flue adapter kit

Use U.L. listed gas vent equipment when installing the FAW-55. For vent pipe running through walls, roof, and within one (1) inch (25mm) of combustible construction, use B01 [one inch (25mm) clearance to combustibles] vent pipe. Type B-2 x 4 or Type B-2 x 6 are to be used in conjunction with a Listed fire stop spacer.

Type BW gas vent pipe is available for single story or multi-story installations, Type BW gas vent pie is to be used with the Listed base plate, ceiling plate spacers and fire stop spacers.

Empire Comfort Systems, Inc.

918 Freeburg Ave. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 FAX: 618-233-7097 or 800-443-8648 info@empirecomfort.com

12428-3-0706

www.empirecomfort.com

Page 12

 

Image 12
Contents Installation Instructions Instructions to Installer Installation on Rugs and TileInstallation in Residential Garages IntroductionSafety Information for Users of LP-GAS Qualified Installing Agency Before Installing Consider The Following VentingInstalling Optional Side Outlets Installing Optional Rear OutletInstallation of Three-prong Grounding Plug Assembly Locating Furnace On WallLocating Gas Supply Location Electric SupplyInstalling a New Main Gas Cock Pressure Testing of the Gas Supply SystemAttaching Furnace to Wall Gas SupplyWiring Thermostat InstallationProper Pilot Flame Proper Main Burner FlameVent Safety Shutoff System If Electrode Does Not Produce SparkIf Pilot Does Not Light By Any Means If Pilot Does Not Remain On After Releasing KnobFor Your Safety Read Before Lighting How To Order Repair Parts 12428-3-0706 SOR-1