Lennox Hearth HCI-42, RDI-42 Typical Installation, Precautions, Introduction, Chimney System

Page 3

PRECAUTIONS

Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a qualified or certified “tradesman” familiar with commonly accepted fireplace installation and safety tech- niques as well as prevailing local codes.

The most important areas of concern dealing with the installation of factory-built fireplaces are clearances to combustible materials, proper as- sembly of component parts, height of the chim- ney system, the proper use of accessories sup- plied by the manufacturer and the techniques employed in using finishing materials applied to the wall surrounding the fireplace, hearth exten- sions and wall shields. Each of these topics will be covered in thorough detail throughout this manual. Please give each your special attention as you progress with your installation.

INTRODUCTION

General Information

These fireplaces are conventional radiant heat fireplaces with standard bar grates, optional outside combustion air kits and optional deco- rative glass doors.

The "C" models are designed as heat circulating fireplaces and may be fitted with accessory fans.

Note: Illustrations shown reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to indi- vidual design preferences. However, always maintain minimum clearances to combus- tible materials and do not violate any spe- cific installation requirements.

These fireplaces have been tested and listed by Omni-Test Laboratories (Report No. 116-F-52-2) to U.L. standard 127. These units are intended for installation in residential homes and other buildings of conventional construction including commercial, not in mobile homes.

These fireplaces have been tested for instal- lation in Canada to ULC-S610. For installa- tions in Canada, the chimney clearance to combustibles must be 2 inches and the Cold Climate Kit must be installed.

These fireplace systems are designed for installation in accordance with the National Fire Protection Standard for chimneys, fire- places and solid fuel burning appliances; NFPA 211 and in accordance with codes such as the BOCA Basic/National Codes, the Standard Mechanical Code and the Uniform Building Codes.

WARNING: FAILURE TO USE MANUFAC- TURE PROVIDED PARTS, VARIATIONS IN TECHNIQUES AND CONSTRUCTION MA- TERIALS OR PRACTICES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY CREATE A FIRE HAZARD AND VOID THE LIMITED WARRANTY.

When complete these fireplace systems con- sists of four basic “sub-systems”:

1.The Fireplace

2.The Chimney and Termination

3.The Optional Glass Doors

4.The Optional Combustion Air Kits

5.Optional Cold Climate Kit (Mandatory in Canada).

CLEARANCES AND HEIGHT

REQUIREMENTS

The fireplace may be placed on or near normal construction materials*. The combustion air kit, firestop spacer and roof flashing (not chase flashings) may be placed directly on or against normal construction materials.* The chimney requires a minimum 2" air space clearance to combustibles. The fireplace outer wrapper requires a minimum 1" air space clearance to combustibles. A combustible mantle may be installed 12" above the opening of the fireplace as per NFPA 211, Section 7-2.3.3. In Canada, the minimum is 18" above the fireplace opening.

TYPICAL INSTALLATION

 

Blower Kit

 

(Optional)

Chimney and

Chimney and

Termination

Termination

Outside

 

Combustion

Outside

Air Kit

(Optional)

Combustion

 

Air Kit

 

(Optional)

Radiant Model Shown

Circulating Model Shown

Figure 1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

The minimum installed height of the completed fireplace system is 15' 0". The maximum height is 60' 0".

The fireplace and chimney system must be enclosed when installed in or passing through a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury or fire hazard.

For questions, please call your distributor or the manufacturer. Special restrictions apply to the front and facing of the fireplace and nearby walls (See pages 16, 17 and 18 ).

CHIMNEY SYSTEM

These fireplaces are designed and code listed for use with Security Chimneys FTF8 chimney System only. Always use Security Chimneys FTF8 chimney components with these fire- places. Do not modify or alter these compo- nents as this may cause a potential serious hazard and void the Warranty.

*Construction Materials:

 

• framing materials

• paneling

• particle board

• flooring

• dry wall

• etc.

• plywood

 

3

Image 3
Contents Omni Report No -F-52-2 Wood Burning Fireplaces P/N 850,047M REV. B 12/2008Table of Contents Clearances and Height Requirements Typical InstallationPrecautions IntroductionBefore You Start Assembly OutlineChimney Height Chase EnclosureClearances Assembly StepsPRE-INSTALLATION Notes Installing the FireplaceRight Side Fireplace SpecificationsFront Left SideFraming Specifications Chimney Duct Duct Collar Front Cover Plate a Plate B Installing the Chimney SystemFor Canadian Installations Proceed with Steps 5 through 8d Nail Or EquivalentFTF8-S4 Stabilizer Or CeilingFor Canada Only Open Attic SpaceUsing a FTF8-CT2 Chase Termination Using a FTF8-CTD Round TerminationUsing a FTF8-CTDT Chase Termination Using a FTF8-CT1 Chase TerminationSpecial Offset Instructions TEN Foot Rule SummaryMultiple Terminations FTF8 Chimney Component CalculationsNumber Of FTF8 FTF8 Vertical Elevation ChartOffset Calculations Chimney OnlyHeight Offset Elevation ChartOffset StabilizerOptional Equipment Considerations Installing OffsetsOffset Elbow Assembly Return Elbow AssemblyCombustion Air Kits Gas Line ConnectionVent Free Appliances Mantels and Trim Glass DoorsCold Climate Insulation Fireplace FinishesInches = Hearth Extension DimensionsMethods of Determining Hearth Extension and Wall Shield TL = minimum thickness of listed materialRM = rM x TS = 0.05 x 3/4 = Finish to Your TasteSum of all R values is .70 + .10 + + .10 = Value = 1/k = r x thickness of material usedInstallation Components Shipping Weight188 lbs 850,047M REV. a 12/2008 Orange, CANot Provided

RDI-42-H, HCI-42-H, RDI-42, HCI-42 specifications

The Lennox Hearth series includes some of the most impressive gas fireplaces available, such as the HCI-42, RDI-42-H, HCI-42-H, and RDI-42. These models are designed to blend efficiency, style, and comfort, making them ideal for modern homes.

One of the standout features of these fireplaces is their versatile design. They come in various sizes to fit a range of spaces while offering customization options that allow homeowners to tailor their aesthetic, including various trim finishes and decorative options. The HCI-42 and RDI-42-H models are particularly noted for their seamless integration into both traditional and contemporary home decor.

The technology behind Lennox Hearth fireplaces ensures high performance and efficiency. Utilizing advanced burner technology, these models provide realistic flame patterns and a beautiful glowing ember bed, creating a captivating visual experience. The direct vent system allows for efficient heating while minimizing heat loss, making these fireplaces ideal for energy-conscious consumers. With a focus on environmentally friendly operation, these units produce fewer emissions compared to traditional wood-burning fireplaces.

User convenience is also a top priority with Lennox Hearth. Many models feature remote control functionality, allowing users to adjust heat and flame settings effortlessly. The easy-to-use thermostatic controls enable homeowners to maintain their desired comfort level without the hassle of manual adjustments. Additionally, the lightweight construction and simplified installation process make it easier for homeowners and contractors alike to set up these fireplaces.

Safety features are integral to Lennox Hearth products. These include sealed combustion systems that prevent outdoor air from entering the home and built-in safety shut-off systems to ensure peace of mind. The HCI-42 and its counterparts have been rigorously tested for safety and performance, adhering to strict industry standards.

In summary, the Lennox Hearth HCI-42, RDI-42-H, HCI-42-H, and RDI-42 bring together cutting-edge technology, beautiful design, and ease of use to offer homeowners a top-tier fireplace experience. With their efficient heating capabilities, customizable aesthetics, and emphasis on safety, these models stand out as exceptional choices for modern living spaces. Whether you are looking to enhance your home’s ambiance or increase energy efficiency, Lennox Hearth fireplaces are a smart investment for any homeowner.