WARNING

Carbon monoxide poisoning: early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtainfreshairimmediately.Turn off the gas supply to the appliance and have it serviced by a quali- fied professional, as it may not be operating correctly.

WARNING

Children and adults should be alerted to the hazards of high surface temperatures. Use cau- tion around the appliance to avoid burns or clothing ignition.

 

 

Note:The gas supply

 

 

line must be installed

 

 

in accordance with

 

 

 

building codes by a

 

 

 

qualified installer

 

 

 

approved and/or

 

 

 

licensed as requed

 

 

 

by the locality. In

 

OFF/PILOT/ON (gas control knob)

the Commonwealth

HI/LO (flame height

 

 

of Massachusetts,

 

 

installation must

control knob)

 

 

 

 

 

 

be performed

 

 

 

 

 

 

 

 

by a licensed

OFF/ON Switch

 

Gas Flex Line

plumber or gas

 

 

 

fitter.

Hinge Pin

 

 

 

 

 

 

 

 

 

Gas Valve

Control

Piezo Igniter

 

 

 

 

 

 

Compartment Access panel

 

 

Figure 1 - Gas Control Compartment Access

 

 

 

OPERATION AND CARE OF YOUR

 

SIT Millivolt

Gas Valve

APPLIANCE

 

 

HI/LO Variable

 

 

 

 

 

Inlet Pressure Tap

The standard controls for appliance operation

Flame Height

 

Adjustment

 

 

are located behind the hinged drop-down panel

 

 

Manifold Pressure Tap

Youngchildrenshouldbecarefully supervised when they are in the same room as the appliance.

Note: An Optional Screen Heat Guard for the glass is available (see Page 14 for ordering infor- mation).

below the appliance front glass enclosure panel (see Figure 1). Optional control switches are also available (see Page 12 - Remote Wall

Switch, Remote Control or Wall Thermostat).

Operation of millivolt and electronic gas con- trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 1 for access

 

 

 

OUT

IN

TPTH

 

 

 

 

T

 

I H

 

 

P

 

 

OFF

 

 

 

 

P

 

 

 

 

 

 

 

 

I

 

 

LO W

it

L

TH

 

O

 

 

 

NO

T

 

 

 

 

 

 

P

 

 

 

I

 

 

 

TOL

 

 

 

Pilot Adjustment

Main Gas

Screw

Control Knob

 

OFF/PILOT/ON

WARNING

Any safety guard or screen removed for servicing the appli- ance must be replaced prior to operating the appliance.

Gas Control Compartment Access

The gas controls can be found behind the control compartment access panel.

To open the control compartment access panel,

to the gas control valve.

Millivolt Appliances - Appliances with Millivolt systems will be fitted with the gas control valve shown in Figure 2.

Electronic Appliances - Appliances with electronic systems will be fitted with the electronic valve shown in Figure 3.

Millivolt Appliances -

To light millivolt appliances refer to the detailed lighting instructions found on Page 15 . Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.

Gas

Outlet

Terminals

TPTH,TP & TH

 

 

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

Gas

Inlet

TPTH

 

TP

 

TH

 

HI/LO Variable

Main Gas

Flame Height

Control Knob

Adjustment

OFF/PILOT/ON

OFF/ONIGNITER (burner)

4

actuate the spring-loaded magnetic catches securing the panel. First, depress the outer top right corner of the panel until the catch "pops" the door free. Then, gently pull the door forward until the left top corner "pops" free, allowing the panel to swing out and down to open.

On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel. See Figure 1.

To ease door closure, depress the catches to place them in their retracted position, then close the door.

Millivolt appliances are fitted with an OFF/ON Rocker Switch located behind the control compartment access panel, below the appli- ance front glass enclosure panel (see Figure 1 for location). Once the pilot is lit, the OFF/ON rocker switch will control the appliance OFF/ON burner operation. To operate: Toggle the switch between its ON and OFF positions.

If your millivolt appliance is equipped with an optional remote switch kit (wall switch, remote control or wall thermostat) and the pilot is lit, the appliance main burner may be turned on and off using the optional switch. When using an optional remote switch, turn off the standard OFF/ON switch.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

 

Note: The piezo igniter and burner

 

OFF/ON switch are located below

Figure 2

glass panel (see Figure 1).

Note: To prevent excessive resistance in burner circuit (which can cause burner operation prob- lems), only one burner control switch should be wired to valve. Therefore, if an optional control switch is installed, the standard Off/On switch and wires should be removed.

Electronic Appliances -

To light electronic appliances refer to the detailed lighting instructions found on Page 16. Elec- tronicappliancelightinginstructionsmayalsobe found on the pull out lighting instruction labels attached to the gas control valve.

Image 4
Contents 875,025M REV. NC 04/2005 MPD35ST-NM MPD35ST-NE MPD35ST-PMFaire la demande. Numéro de la pièce 875,025CF Listing AgencyCongratulations Burn-in Period Manifold Gas Supply Pressure Electronic models Fuel # FixedOrifice Sizes Sea Level to High Altitude All Models Burner Orifice Sizes all models Elevation Natural PropaneAppliance Operation and Care of YourSIT Millivolt Millivolt AppliancesMaintenance See Maintenance Schedule,Front Glass Enclosure Panel, Removal and Installation See FigureLOG SET Identification CA BLOG SET ReferencePlacement of Glowing Embers Read LOG Warnings on page 9 Before ProceedingRemove front glass enclosure panel from appliance Against The GrateBurner Adjustments Qualified Technicians only Air Shutter Adjustment GuidelinesThis appliance is not designed to burn wood. Any attempt to Flame Appearance & SootingElectronic Pilot Assembly Wiring Diagrams Warranty Replacement PartsAccessory Components Product Reference InformationClean Face Panel Kits Arch Design Arch PaneSquare Louvers KitsScreen Heat Guard Kit Arch Door KitsForced Air Kit Door Frame KitsTo Turn OFF GAS to Appliance What to do if YOU Smell GASSwitch What to do if YOU Smell GASLighting Instructions Close lower control compartment doorMaintenance Task Accomplishing Person Procedure Maintenance ScheduleWhile HOT Troubleshooting Symptom Possible Causes Corrective ActionOperation, if the standard burner PositionTroubleshooting Procedure Electronic Ignition System Replacement Parts MPD35ST Description Where UsedPart/Cat Qty Description Where Used 20 P/N 875,025M REV. NC 04/2005

MPD35ST-NE, MPD35ST-PM, MPD35ST-NM specifications

The Lennox Hearth MPD35ST series, which includes the MPD35ST-NM, MPD35ST-PM, and MPD35ST-NE models, is designed for homeowners seeking superior heating solutions with aesthetic appeal. These multi-position direct vent gas fireplaces combine efficiency with advanced technology, ensuring that both performance and style are prioritized in any living space.

One of the standout features of the MPD35ST series is its innovative Direct Vent technology. This system draws air from the outside for combustion, eliminating the need for indoor air and thereby reducing energy consumption and improving indoor air quality. This feature not only enhances efficiency but also provides a safe and comfortable environment for your home.

The MPD35ST fireplaces come with a variety of design options to suit different decor styles. With a variety of front options, including sleek and modern designs or classic and rustic looks, homeowners can customize their fireplace to match their aesthetic preferences. The 'No Media' (NM) style offers a clean and minimalist contemporary design, while the 'Panel Media' (PM) and 'Enhanced Media' (NE) styles feature options for adding decorative media, such as pebbles or logs, that enhance the visual ambiance of the fire.

These units also incorporate advanced heating technologies, featuring high-efficiency burners that produce significant heat output with minimal energy consumption. With adjustable flame settings, users can control the intensity of the heat while enjoying the mesmerizing flicker of the flames. This flexibility allows homeowners to create a cozy environment tailored to their comfort needs.

In addition, the Lennox MPD35ST series is designed with user-friendly controls that simplify operation. Integrated remote controls allow for easy adjustment of the temperature and flame settings from the comfort of your seat. Safety is a paramount consideration; these fireplaces are equipped with built-in safety shut-off systems that ensure worry-free operation.

Furthermore, the construction of the MPD35ST series focuses on durability and longevity. Made from high-quality materials, these fireplaces are built to withstand the test of time, providing both reliable performance and an attractive focal point in any room.

In summary, the Lennox Hearth MPD35ST-NM, MPD35ST-PM, and MPD35ST-NE models epitomize modern fireplace design. With their energy-efficient technologies, customizable aesthetic options, and user-friendly features, they are an excellent choice for homeowners looking to enhance their living spaces with both comfort and style.