User’s Information
SET-UP MODE
You can customize the performance of the air cleaner to meet the needs of your home and family using the
To enter the
You may select the cleaning intervals of the
Factory settings
DIRTY R3
R2
R1
Y4
Y3
Y2
Y1
G3
G2
CLEAN G1
Field Charger Power Maximum
Collection Cell 6 Months
2 Months
RESET buttons for a minimum of 5 seconds to
exit the
Pre-Filter Timer Setting
Fig. 3
The GREEN LED lights are used to set the
setting is 2 months.
Collection Cell Timer Setting
The YELLOW LED lights are used to set the collection cells cleaning interval for two, four, six, or nine months. The number of illuminated YELLOW LED lights indicates the current setting as shown in Figure 5. The factory setting is 6 months.
Field Charger Power Level Setting
The RED LED lights are used to set the power level of the field charger for maximum, medium, or minimum. The number of illuminated RED LED lights indicates the current setting as shown in Figure 6. The factory setting is for maximum.
Lower settings will reduce the slight sound emitted by the unit with minimal loss of air cleaning efficiency, if desired.
Lower settings will also further reduce the very low ozone produced by the air cleaner. The U.S. Food and Drug Administration recommends indoor ozone concentrations should not exceed 50 parts per billion. Your air cleaner will contribute only 5 parts per billion at the factory setting and can be reduced to 3 parts per billion at the minimum setting.
5 |