THE LIMITATIONS OF THIS ALARM SYSTEM

While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example:

Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device.

Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.

Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.

A user may not be able to reach a panic or emergency button quickly enough.

While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.

Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can decrease.

Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.

Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.

Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately.

This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to

last as long as 10 years, the electronic components could fail at any time.

The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly.

Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property.

We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments.

– 72 –

Image 72
Contents VISTA-128FBP VISTA-250FBP Page Table of Contents Panic Keys System Overview GeneralPartitioned System System Overview cont’d ZonesFire Protection Burglary ProtectionAlarms Memory of AlarmUsing Schedules Carbon Monoxide ProtectionDevice Timers To Access another Partition Goto CommandMaster Keypad Operation Self-Help Feature To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions of the Keypad Functions of the Keypad cont’d Burglary KeypadTest Functions of the Keypad cont’d Entry/Exit Delays General InformationSecurity Codes and Authority Levels Duress CodeQuick Arming Security Codes and Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Accessing Other Partitions To Access another PartitionGlobal Arming To Goto another partitionAccessing Other Partitions cont’d SystemStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation How User Codes Affect the Common Lobby Codes with Global ArmingCodes with Non-Global Arming Other Methods of Arming/DisarmingUsing Ready Key To show faulted zonesTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Using Bypass Key Bypassing Protection ZonesTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomTo use the Quick Bypass feature Bypassing Protection Zones cont’dQuick Bypass Displaying Bypassed ZonesTo use the Group Bypass feature Group BypassUsing Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing Instant Key Armed *INSTANT1 Zone BypassedUsing the 2 Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Disarming and Silencing Alarms Using the 1 OFF KeyTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMUsing the Keyswitch ArmingDisarming To arm in the Stay mode, turnChime Mode Using KeyChime Mode on Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysRelay Control ExecutingUsing #70 Relay Menu Mode Enter Device noUsing Schedules Delaying the Closing TimeClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsTo enter the Instant Activation Mode Action ? Are YOU SURE?Quit Menu MODE? Zone LIST?Event Log Procedures Enter Code + # + 6 + Select the display modeEnter 0 = Recent 1 = Complete Select the partitionEvent Logging Procedures Alarm Event LOGBurglary C003 To Exit the Event Log Press at any timeUsing Test Key Testing Your SystemFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Fire Alarm System cont’d Event Display LockFire Drill Test Code + # + Trouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dEmergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Action Procedure Quick Guide to Fire System FunctionsFunction Procedure Comments Quick Guide to Burglary System FunctionsQuick Guide to Burglary System Functions cont’d Summary of Audible Notification Alpha Display KeypadsIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Access Another Partition Index65, 66 TWO Year Limited Warranty Page Page Page Page ÊK0377V2eŠ