User Codes

TO ADD OR CHANGE A USER CODE

Users can be added or changed directly at the keypad. Your system can have up to 15 (OMNI400 and OMNI600), 32 (OMNI624), or 64 (OMNI848) different user codes, with each assigned to one of four authority levels and to a primary partition (OMNI624 and OMNI848 only). The authority level determines the functions that user can perform. In addition, your system can be set up for 4-digit or 6-digit user codes. Ask your installer which type of user codes is used in your system.

To add or change a user code, press the following:

CODE /

 

 

+

 

 

 

 

 

 

Master User Code

User ID*

New User Code

nn

Auth. Level

[1-4]

*Valid User ID numbers are 01–15 for the OMNI400 and OMNI600, 01–32 for the OMNI624, or 01–64 for the OMNI848.

Authority Levels

Level Functions Allowed

1Primary Master: access all partitions; can view log and set time; assign other user codes; all system functions

2Secondary Master: same as primary master except cannot change the primary master’s code

3User: cannot assign codes and cannot bypass zones

4Limited user: same as level 3, except can disarm the system only if it was armed by another user with level 4 authority (cannot disarm if armed by user of higher authority level).

ASSIGNING PARTITIONS TO USERS (OMNI624 and OMNI848 ONLY)

When a user code is assigned, that user is automatically allowed to perform system functions in the partition in which the user’s code is assigned. You can also allow users to access other partitions and turn on open/close reporting to a pager by using the #7 command as follows:

#7 [master user code] [user no.] [1, 2, 3*, or 4]

where: master user code = user with authority level 1 or 2

user no. = the user that will be assigned access to other partitions

1, 2, 3, or 4 = enter the partition(s) 1-3* you want this user to have access to; enter 4 if you want this user to send open/close reports to a pager

* Partition 3 is available on the OMNI848 ONLY.

- 15 -

Image 15
Contents N9939V5 4/04 Rev. a Fbii Security SystemTable Of Contents Quick Reference Key Description Keypads Comments Quick ReferenceOther LED display combinations Quick Reference Cont’dIntroduction Entry time Door Exit time System ReferenceZone Descriptions Zone DescriptionPager Alert System ReferenceSEND-HELP Alert KeysdescriptionUser Assigned To… User Code AssignmentsArming the System Is the System READY?To ARM the System and Leave ARM/ and STAY/ LEDs lit When the System is not ReadyArming the System Slow Blink/Low IntensityARM/ , STAY/ , INSTANT/ LEDs lit To ARM the System in Instant ModeTo ARM the System in Instant Mode and Stay Inside ARM/ and INSTANT/ LED litTo Unbypass a Zone To Bypass a Zone+ Zone + Zone NoARM LED/ lit READY/LED blinks Disarming the SystemLCD Keypad Fixed-Glass Keypad LED Keypad READY/ LED litAuthority Levels User CodesTo ADD or Change a User Code To add or change a user code, press the followingQuick Arming Miscellaneous CommandsTo Delete a User Code DuressQuick Exit Miscellaneous CommandsQuick Bypass Digit Zone No. e.g., 01 for zoneDoor Strike Change Partition OMNI624 and OMNI848 onlySET AUTO-ARM Time To View Autoarm TimeSET Time View Time LCD Keypads onlyUser LOG View LCD Keypads only KEY FOB LOW-BATTERY Test OMNI624 and OMNI848 onlyKeypad Backlight Timer Display Zone Directory LCD Keypads onlyKeypad Sounder To change the keypad sounderOMNI-KP or OMNI-KP-US Press the Bypass Changing the Pager Phone Number FOLLOW-ME Using a PagerTurn Pager Reporting ON/OFF for a User Using a PagerTesting the System Battery TestSystem Test Living Room Bedroom Recommendations On Smoke DetectorsEmergency Evacuation Bypass GlossaryGlossary Federal Communications Commission FCC Part Industry CanadaRinger Equivalence Number Notice Industrie Canada Telephone Operational ProblemsLimitations of This Alarm System ÊN9939V54Š

624, 848, 400, 600 specifications

The Honeywell 848,624,600,400 is a sophisticated industrial control system that serves as a vital component in modern automation and control environments. Designed for enhanced flexibility and scalability, this system is particularly suited for industries such as manufacturing, oil and gas, pharmaceuticals, and utilities.

One of the standout features of the Honeywell 848,624,600,400 is its robust architecture, which employs advanced distributed control system (DCS) principles. This allows for real-time data acquisition and processing, ensuring that critical operations are monitored and controlled with high precision. The system supports a wide range of field devices, making it versatile in handling different types of processes.

At the core of the Honeywell 848,624,600,400 is its powerful software platform, which utilizes the latest in analytics and machine learning technologies. This intelligent software enables predictive maintenance, optimizing resource allocation and decreasing unexpected downtimes. Users can leverage comprehensive dashboards that visually represent operational data, allowing for quick analysis and decision-making.

Another essential characteristic of this control system is its ease of integration with existing infrastructures. Honeywell’s open architecture approach facilitates interoperability with third-party devices and systems, which is crucial for companies looking to upgrade without overhauling their entire system. This adaptability not only reduces costs but also minimizes operational disruptions during the transition.

The system also prioritizes cybersecurity, embedding multiple layers of protection to shield sensitive data from unauthorized access. Regular updates are provided to address emerging threats, ensuring that the system remains resilient against cyber risks.

In terms of user experience, the Honeywell 848,624,600,400 features a user-friendly interface that is accessible across various devices. Operators can manage and control processes remotely, enhancing flexibility and responsiveness in operations. The system is designed to support mobile applications, allowing personnel to monitor and control processes while on the move.

Lastly, Honeywell's commitment to support and training ensures that users can fully leverage the system's capabilities. Extensive documentation, online resources, and expert consultations are available, making it easier for organizations to implement and maintain the system effectively.

In conclusion, the Honeywell 848,624,600,400 is a cutting-edge control system that combines robust technology, user-centric design, and a focus on security, making it a vital asset for modern industrial operations aiming for efficiency and reliability.