Honeywell 16103 manual Menu Access, 10 = Setting ent to Select

Page 11

Setting and Unsetting With Group Choice

With group choice, setting is initiated as normal, using a code, tag or fob. However, a choice of groups will then be displayed along with the current status of each group.

The status can be changed for each group by pressing the appropriate number button and the display will cycle through the possible options.

SET 123

GROUPS SUU

S = SET

U = UNSET

Pressing the ent key will implement the status shown.

If a code, keyfob or tag is used while an entry timer is running or an alarm is in progress, the group that is active will be unset immediately, without any status needing to be changed on the keypad.

Menu Access

To access the other functions of the system, users can enter the menu mode by typing their PIN code and pressing the ent button. This will display the first menu item after showing system status for 5 seconds.

10 = Setting [ent] to Select

Users can then navigate around the menu using the scroll keys, ent key and esc key, or they can jump to any specific menu item directly by typing the number of the item. An overview of all the accessible functions is shown below. Not all users will be able to access all of the functions. This will depend on their ‘user type’ that is set up in menu 42.

 

 

 

 

10 = Setting

20 = Display

30 = Test

40 = Modify

11 = Omit Zones

21

= Zone Status

31

= Walk Test

41 = Time/Date

12

= Timed Set

22

= View Log

32

= Output Test

42

= Users

 

 

 

 

 

 

 

 

13

= Part Set

23

= System Version

 

 

44

= Mobile Nos

 

 

 

 

 

 

 

 

14

= Night Set

24

= Print

 

 

47

= Remote Access

 

 

 

 

 

 

 

 

15

= Chime

 

 

 

 

48

= Level 3 Access

 

 

 

 

 

 

 

 

Table 1. Menu Access

The function of each menu item is described in the following pages.

7

Image 11
Contents Galaxy Page Table of Contents Iii Page Introduction Groups Controlling Your Alarm SystemUsers Prox Tags/Cards KeypadsOpen Zone 1044 Setting the System Full SetWireless Keyfobs 060030 Setting the System Part or Night SetSetting with Faults Fault Override EventsSetting and Unsetting Groups Cancelling System SettingUnsetting Cancelling an AlarmSET Menu Access10 = Setting ent to Select Setting and Unsetting With Group ChoiceMenu 14 Night Set Menu 11 Omit ZonesMenu 12 Timed Set Menu 13 Part SetMenu 24 Print 0951 01/08/04 1021+ IntruderMenu 22 View Log Menu 23 Display VersionMenu 42 Editing Users Menu 31 Walk TestMenu 32 Output Test Menu 41 Time/Date= Master User 1 *1234 UserL2Menu 44 Mobile Numbers Menu 47 Remote AccessMenu 48 Level 3 Access Zone Reference Table Installer DetailsIU1-0032 Rev

16103 specifications

The Honeywell 16103 is a vital component in various industrial applications, recognized for its advanced technology and reliability. Renowned for its robust design, the 16103 sensor excels in monitoring and control systems across different sectors, including HVAC, manufacturing, and building automation.

One of the key features of the Honeywell 16103 is its temperature sensing capability. The device employs a thermistor technology, allowing it to provide accurate readings across a broad temperature range. This reliability is essential for applications where maintaining precise environmental conditions is critical. Additionally, the sensor's fast response time ensures that any fluctuations can be detected and acted upon promptly, which enhances overall system efficiency.

Moreover, the Honeywell 16103 boasts excellent linearity and a wide operating range, delivering exceptional performance even in challenging conditions. The sensor's excellent linear characteristics ensure that the measurements are not only accurate but also consistent across various operating scenarios. This means users can trust the data provided by the 16103, leading to more informed decision-making and improved operational control.

Another significant aspect of the 16103 is its versatility. It is designed to seamlessly integrate with a wide range of control systems and communication protocols. This flexibility makes it suitable for many applications, from simple temperature monitoring to complex building management systems. Users can expect easy installation and configuration, which reduces down-time and increases productivity.

The Honeywell 16103 also emphasizes durability. Built with high-quality materials, it exhibits resistance to environmental factors such as humidity and dust, extending the sensor's operational life. This robustness is particularly advantageous for industrial applications, where equipment is often exposed to harsh conditions.

In summary, the Honeywell 16103 is a sophisticated temperature sensor that combines accuracy, reliability, and versatility with superior build quality. Its advanced thermistor technology, quick response time, and compatibility with diverse systems make it a cornerstone for effective monitoring and control solutions in various industrial sectors. Whether for HVAC systems or industrial automation, the Honeywell 16103 stands as a reliable choice for professionals seeking to optimize their operational environments.