Configuration Menu
Step | Press Button(s) | Displayed (Factory Default) | Press | or | to select: | Comments |
|
|
|
|
|
|
|
1 | PRGM and RUN | (FA) |
| SL |
| Select FA or SL (Fast or Slow) heating cycle rate |
|
|
|
|
|
|
|
2 | HOLD* |
| OFF |
| Select display backlight OFF or ON | |
|
|
|
|
|
|
|
3 | HOLD* | E (ON) |
| OFF |
| Select Energy Management Recovery OFF or ON |
|
|
|
|
|
|
|
4 | HOLD* | LOC (OFF) |
| ON |
| Select compressor lockout OFF or ON |
|
|
|
|
|
| |
5 | HOLD* | 0 HI (0) |
| 4 LO to 4 HI | Select temperature display adjustment higher or lower | |
|
|
|
|
|
|
|
6 | HOLD* | (F) |
| C |
| Select temperature display to F or C |
|
|
|
|
|
|
|
7 | RUN |
|
|
|
| Returns to normal operation |
|
|
|
|
|
|
|
*Press HOLD to advance to next item or TIME to move backwards to previous item
The only way to restore this feature is to complete a software reset (see reset operation under “TROUBLESHOOTING” section).
•COPY DAY
6 CONFIGURATION MENU
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal require- ments.
Press RUN to make sure the thermostat is in the run program mode, then press PRGM and RUN at the same time to enter the configuration menu. The display will show the first item in the configuration menu.
The configuration menu table summarizes the configuration op- tions. An explanation of each option follows.
Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.
1)Select FA or SL (Fast or Slow) Heating Cycle
your personal preference. FA cycles the system just under 1°F and the SL setting cycles at approximately 1.5F°.
2)Select backlit
3)Select Energy Management Recovery OFF or ON— Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building
temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint.
Example: You select EMR and have your heating pro- grammed to 65° at night and 70° at 7 AM. If the building temperature is 65° the difference between 65° and 70° is 5°. Allowing 5 minutes per degree the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per degree because it takes longer to reach temperature.
4)Select Compressor Lockout LOC OFF or
occurs it will flash the for about five minutes then turn on the compressor.
5)Select Temperature Display Adjustment 4 LO to 4 HI— Allows you to adjust the room temperature display 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display tem- perature to match your previous thermostat.
6)Select F° or C°
7 PROGRAMMING YOUR THERMOSTAT
This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.
•When heating (cooling) your building, program the tempera- tures to be cooler (warmer) when the building is vacant or during periods of low activity.
•During early morning hours, the need for cooling is usually minimal.
Look at the factory preprogrammed times and temperatures shown below. If this program will suit your needs, simply press the RUN button to begin running the factory preset program.
If you want to change the preprogrammed times and tempera- tures, follow these steps.
Determine the time periods and temperatures for each day programs. You must program four periods for each day program.