WIRING INSTRUCTIONS

Standard electrical wiring of 120 volts, 60 Hz, 15 Amp circuit is adequate. Local residential and commercial wiring codes shall apply. Flexible conduit should be used (Fig. 5).

BOX (INTERNAL)

TOP OF

 

UNIT

 

GREEN

 

 

FIELD GROUND

WHITE

FIELD NEUTRAL

BLACK

FIELD HOT

FIG. 5 Electrical connection

OPERATION/MAINTENANCE

OPERATION

1.With the 120 VAC power turned on, adjust the knob to the position desired.

2.When the fan is running, the air cleaner will be operating. An arcing or “snapping” sound may be heard occasion- ally, however the unit is operating properly.

3.The Operating Light should be ON whenever the fan is running. An occasional flicker of the light accompanied by harmless sparking or snapping noise may occur. This is caused by the plates trapping large particles. If arcing is continuous, the cells should be washed or checked for service problems.

WASHING

! CAUTION

CABINET AND CELLS MAY CONTAIN

SHARP EDGES.

Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury.

For maximum efficiency, your air cleaner cell and pre-filter should be inspected periodically and cleaned when neces- sary. The cleaning frequency will vary, depending on the amount of airborne contaminants. When cleaning is required the following procedure should be used:

CLEANING THE CELL

1.Turn the control switch to “OFF”.

2.Open the door, slide out charcoal filter, cell and pre-filter and re-close the door for safety. Replacement charcoal filters are available for odor control (see parts list).

NOTE: Do not wash the charcoal filter.

3.Using a solution of warm water and low sudsing detergent, soak cell for 20 to 30 minutes.

NOTE: Ionizing wires may become coated, causing loss of cleaning ability by the collecting cell. Using a damp cloth, wipe each ionizing wire, exercising care not to damage them.

4.Remove the cell from solution and rinse thoroughly with clean water. After removing cell, wash and rinse pre- filter.

5.Allow cell and pre-filter to drip dry for a minimum of

2 hours. Cell may be tipped at a slight angle to expedite the drip-dry process.

6.Open door and replace charcoal filter.

7.Slide cell into unit with air flow arrow pointing in direction of air flow.

8.Slide pre-filter screen into unit.

9.Close the door and securely fasten.

10.Turn the control switch to desired fan speed.

A moderate amount of arcing or “snapping” may occur at this time, which will indicate that the cell is still damp. If the noise is objectionable, turn the control switch to “OFF” and allow additional time for the cell to dry.

4

Image 4
Contents CSC1000 Part no -6336ARules for Safe Installation and Operation HOW the AIR Cleaner WorksElectrocution Hazard Cabinet and Cells MAY Contain Sharp EdgesInstallation PlacementCeiling Mount Mounting DetailOPERATION/MAINTENANCE Wiring InstructionsCleaning the Cell OperationService Indication Service Checks Technical Repair GuideWiring Diagram Ozone ReductionReplacement Parts Diagram CSC1000White-Rodgers Electronic Air Cleaner Wash Reminder Schedule

CSC1000 specifications

The White Rodgers CSC1000 is an advanced thermostat designed to optimize home climate control with a blend of modern technology and user-friendly features. This programmable thermostat is particularly popular among homeowners seeking to enhance energy efficiency while maintaining comfort throughout their living spaces.

One of the standout features of the CSC1000 is its intuitive touchscreen interface, which simplifies programming and daily adjustments. Users can easily navigate through menus, set schedules, and make temperature adjustments with just a few taps. The bright display enhances visibility, even in low light conditions, making it convenient for users of all ages.

The CSC1000 also supports a 7-day programmable schedule, allowing users to customize heating and cooling settings according to their daily routines. This flexibility ensures that energy is not wasted during hours when the home is unoccupied. Additionally, users can take advantage of the system’s ability to store multiple schedules, making it easy to switch between different programs for weekends or holidays.

In terms of connectivity, the White Rodgers CSC1000 incorporates advanced technologies, including Wi-Fi compatibility. This allows users to control their thermostat remotely through a smartphone app, enabling adjustments on-the-go. Whether at work or on vacation, homeowners can monitor their HVAC systems, receive alerts, and even adjust the temperature to ensure a comfortable environment upon their return.

Energy efficiency is at the forefront of the CSC1000’s design. The thermostat features adaptive recovery, a technology that learns how long it takes to reach a desired temperature. This predictive adjustment not only maximizes comfort but also minimizes energy consumption by preventing unnecessary heating or cooling.

The CSC1000 is also equipped with filter change reminders, which promote efficient operation of HVAC systems. Regular maintenance is crucial for optimal performance, and these reminders help users stay on top of necessary filter changes for cleaner air and improved efficiency.

In terms of compatibility, the White Rodgers CSC1000 works with a variety of heating and cooling systems, including gas, electric, and heat pump setups. This versatility makes it an attractive option for many homeowners looking for a dependable thermostat to enhance their home climate control systems.

Overall, the White Rodgers CSC1000 combines advanced technology, ease of use, and energy efficiency to deliver a top-notch home heating and cooling solution. Its features cater to modern needs, making it a standout choice for those seeking to optimize their home environment while saving on energy costs.