Annual maintenance

Electrical Shock Hazard

Unplug before doing any maintenance.

Do not drink water collected by the air conditioner.

Failure to follow these instructions can result in death, electrical shock, or sickness.

1s:oHzzand 1

Failure to do so can result in back

Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year.

Call the service company recommended by your dealer to:

l Inspect and clean the coils and condensate water passages.

l Check fan and fan motor.

The compressor is sealed and needs no oiling. The expense of an annual inspection is the customer’s responsibility.

OR

If you are familiar with electrical appliances, you can do the cleaning and maintenance yourself. If you choose to do so, follow these steps:

1.Unplug air conditioner or disconnect power.

2.Remove the air conditioner from the window channel frame and off of the support platform.

3.Remove the front panel. (See page 14.)

4.Remove the screws from the top and sides of the cabinet, and then remove the cabinet.

5.Wrap the motor, electrical control box, and compressor terminal box in plastic film to make sure no water or other liquid gets inside. Water or other liquids could damage the insulation and cause serious mechanical problems.

6.Clean and hose out the base, coils, and condensate pan. Clean at least once a year, or more often if the condenser coils and pan collect dirt, sand, leaves, insects, or algae. Also, clean if you detect an odor coming from the air conditioner. Do not use the water collected in the air conditioner for drinking purposes. It is not sanitary.

7.Remove the plastic film from the motor and electrical parts.

8.Reattach the cabinet with the screws. Replace the front panel, and reinstall the air conditioner.

NOTE: It is a good idea to wait 24 hours before starting the air conditioner again. This allows time for all areas to dry out. The water from rainfall or from normal operation does not harm these components.

9.Plug in air conditioner or reconnect power.

15

Image 15
Contents Air Conditioner Operating Your Caring For Safety Parts Features ElectricalAir Conditioner Troubleshooting To You AirCenter Our Consumer Assistance 800-253-I 301Thank you for buying a WHIRLPOOL@ appliance Please record your model’s informationAir Conditioner Safety Your safety and the safety of others is very importantHelp us help you Exhaust vent control Parts And FeaturesElectrical Requirements Receptacle wiring Electrical connectionElectrical requirements Tools required Installing Your Air ConditionerPreparing for installation Installation tipsInstalling in a sliding window Step Air \ gottom Window flange channel frame Installing in a casement window Installing in a wood casement windowSliding or wood Operating Your Air Conditioner StartingAir conditioner Changing air direction Using the Exhaust ControlTemperatures Cooling at low outsideCleaning the front panel Cleaning the air filterCaring For Your Air Conditioner 1soHzzand Annual maintenanceSaving energy Understanding normal operating soundsProblem TroubleshootingIf you need assistance Requesting Assistance or ServiceIf you need FSF@ Replacement parts If you need serviceIndex Whirlpool

ACS072XG, ACS102XG specifications

The Whirlpool ACS072XG and ACS102XG are advanced window air conditioning units designed to provide efficient cooling and comfort in various environments. Both models are ideal for residential and small commercial spaces, offering a range of features that cater to modern needs and preferences.

One of the standout characteristics of these models is their energy efficiency. Featuring a high Energy Efficiency Ratio (EER), both the ACS072XG and ACS102XG help reduce electricity consumption while delivering powerful cooling. This efficiency is coupled with the use of eco-friendly refrigerants, aligning with contemporary environmental standards and reducing the carbon footprint.

The design of the ACS072XG and ACS102XG is user-friendly, equipped with easy-to-use electronic controls that enable users to adjust temperature settings and fan speeds effortlessly. These models also incorporate a remote control feature, allowing users to operate the unit from a distance, enhancing convenience for those who prefer not to get up from their seats.

Both units boast a multi-speed fan system, providing customizable airflow settings that cater to different cooling needs. In addition, the units come with an adjustable vent direction, enabling users to direct cool air where it's most needed, ensuring that every corner of the room receives adequate cooling.

Another key feature is the built-in dehumidifier, which helps to reduce indoor humidity levels, creating a more comfortable environment. This function is particularly beneficial in humid climates, allowing residents to enjoy a cooler and drier indoor atmosphere.

The ACS072XG and ACS102XG are designed with low noise operation in mind. This is perfect for maintaining a peaceful atmosphere in bedrooms or workspaces. The sound-dampening technology minimizes operational sounds, allowing users to keep cool without disruptive noise.

In terms of maintenance, both models feature a washable and reusable filter, which is easy to access and clean. This not only helps maintain the efficiency of the unit but also promotes better air quality by trapping dust and allergens.

Overall, the Whirlpool ACS072XG and ACS102XG stand out as reliable and efficient air conditioning solutions that embrace modern technology while ensuring user comfort. With features focused on energy efficiency, convenience, and performance, these models are well-suited for anyone looking to enhance their cooling experience.