Whirlpool 1159801 manual Troubleshooting, Beforeyou call for service, Normaloperatingsounds

Page 8

Troubleshooting

Beforeyou call for service ...

If you are having an operating problem, check the chart to see what the cause might be before you call for assistance.

PROBLEM

Unit won’t run.

Unit blows fuses or trips circuit breaker.

Unit turns on and off, or does not cool room.

CHECK IF

l Power cord is plugged into a live circuit with proper voltage.

l Fuse has blown or circuit breaker has tripped. Also, check if a time-delay fuse has been used.

l System Control is set to OFF.

l Local power has failed.

l Time-delay fuse being used is of correct capacity.

l An extension cord is being used.

l Cooling circuit was turned off and on again quickly.

lFilter is dirty.

l Inside evaporator coils and outside condenser coils are dirty.

l There is excessive heat or moisture in room.

WHAT TO DO

l Firmly plug power cord into electrical outlet. Check circuit voltage at fuse/circuit breaker box.

l Replace fuse with a time-delay fuse of the correct capacity. Reset circuit breaker.

l Set System Control to another setting.

l Wait for power to be restored.

l Replace fuse with a time-delay fuse of the correct capacity.

l Do not use an extension cord with this or any other appliance.

l Wait at least 3 minutes after turning cooling circuit off before trying to restart unit.

l Clean filter. (See page 5.) l Clean coils. (See page 6.)

l Use exhaust fans to reduce room heat, or set Exhaust Control to CLOSED to reduce moisture.

l Fan speed is too low.

l Thermostat setting is too low.

Normaloperatingsounds...

When your room air conditioner is operating normally, you will hear sounds such as:

l Droplets of water hitting the condenser, causing a “pinging” or “clicking” sound. Water droplets help to cool the condenser.

l Air movement from the fan, especially on HI COOL setting.

l“Clicks” from the cooling cycle.

Sounds also may be caused by house construc- tion - such as vibration of the unit due to wall construction or unsteady window mounting area.

l Set System Control to a higher setting.

l Set Thermostat Control to a higher number.

Image 8
Contents Use& CareGuide Contents OperatingYourAirConditioner Startingyour air conditionerLO Cool MED CoolTheexhaustcontrol Changingair directionCleaningYourAirConditioner Cleaningfront panelandair filterAnnual maintenance CaringForYourAirConditionerEnergysavingtips Normaloperatingsounds TroubleshootingBeforeyou call for service RequestingAssistanceorService Forservicein the U.SWhirlpool will not PAY for Whirlpool will PAY for WarrantyLength of Warranty Lnstruccionespara suus0ycuidado Contenido Guarde Estas InstruccionesLnstruccionesde Operacih Encendiendoel acondicionadorde aireEl controlde extraccih de aire Cambiandola direccih del aireLimpiezadelAcondicionadordeAire Limpiezadel paneldelantero y del filtroPage CuidadodelAcondicionadordeAire MantenimientoanualPage Consejosparaahorrarenergia Ruidosduranteel funcionamiento Diagnhtico de ProblemasAntesde llamar para obtenerasistencia SolicitandoAyudao ServicioTknico Paraservicio en 10sEE.UUGarantia