Bosch Appliances D7412GV4, D9412GV4 Systems With Access Control, Systems with Wireless Keyfobs

Page 22

D9412GV4/D7412GV4/D7212GV4 Owner's Manual Supplement

Systems With Access Control

If your system includes access control features, such as card readers at doors, the following prompts can appear during the ADD USER? procedure.

On a D1255 Keypad

ADD CARD? (CHANGE CARD?)

1.If the user has card or token access to the building or area, press [ENT] at the ADD CARD? prompt, or at the CHANGE CARD? prompt if the user already has a card or token.

2.PRESENT CARD appears. Present the card at the card reader and wait for the tone.

3.If the reader identifies the card or token correctly, a tone sounds and the keypad shows CARD ADDED, or CARD CHANGED if the user already has a card or token. Press [ENT].

On a D1260 Keypad

1.From the Add/Change Menu, press the Card softkey.

2.Add Access Card for this user? appears. Press the Yes softkey.

3.Present card to card reader # now. appears. Present access credentials to the associated door reader and wait for a tone.

4.If the reader identifies the credential correctly, a tone sounds and the keypad shows Card Added or Card Changed if the user already has a card or token. Press [ENTER].

2.12.3 Systems with Wireless Keyfobs

If your system has wireless services available, the following options are available to enroll, remove or replace a User Keyfob provided by your security company.

I have this feature.

I do not have this feature.

Enrolling a User Keyfob with RFID

On a D1255 Keypad

1. Ensure that the display shows idle disarmed text.

22

Bosch Security Systems, Inc. 9/11 F01U245224-02

Image 22
Contents Control Panels System Requirements Introduction General Commands Two-Man Rule Using the Two-Man RuleDescription Early Ambush Using Early AmbushEasy Exit Control Switching armed states from Perimeter to Master Passcode Follows ScopePasscode Controlled Menu Walk Tests Using Passcode Controlled Menus On a D1255 KeypadOn a D1260 Keypad Using Walk Test On a D1255 Keypad Point Text Door Activated Custom Function Using Door Activated Custom FunctionsPasscode Functions Dual Authentication Dual Authentication ProcessAccess Level Control Using Access Level CTL?Using Door Control? Door ControlDoor Control? softkey Cycle Door?Key to Symbols Symbol Description Unlock Door?Display shows Unlock Door 1 2 3 U 5 6 7 Secure Door?Delete User Command Using DEL User ?12 Add/Change User Command Using Add User ?Bosch Security Systems, Inc /11 F01U245224-02 Add/Change User? prompt Systems with Wireless Keyfobs Systems With Access ControlEnrolling a User Keyfob with Rfid On a D1255 Keypad Enrolling a User Keyfob with Auto-learn On a D1255 Keypad If successful, Keyfob Added appears. Keyfob User ###Keyfob User ### Rfid Not Assigned. Press the Exit softkey Replace a User Key Fob On a D1255 Keypad Remove a User KeyfobPress the Next softkey. Press the Remove Keyfob softkey False Alarm Reduction Features System RequirementsExit Error User-Caused False Alarms, Arming the SystemExit Time Defaults Exit ToneEntry Time Defaults User-Caused False Alarms, Disarming the SystemMaster Arm − No Exit Feature Unvacated Premises Recent ClosingPasscode Acknowledges Alarm Arming and Disarming with KeyswitchesAlarm Transmission Sequence Alarm Abort Abort WindowAlarms Acknowledged within the Abort Window Cancel Report and Cancel WindowDuress Alarm At the End of the Alarm Abort WindowBosch Security Systems, Inc
Related manuals
Manual 36 pages 16.55 Kb

D7412GV4, D7212GV4, D9412GV4 specifications

Bosch Appliances has long been synonymous with quality and innovation in the home appliance market. The D7212GV4, D7412GV4, and D9412GV4 models are part of their esteemed line of high-performance appliances, designed to meet the demands of modern kitchens and households. These models come equipped with advanced features and technologies to enhance user experience, efficiency, and convenience.

The D7212GV4 is characterized by its compact design, making it ideal for smaller kitchens or spaces where every inch counts. Despite its size, it boasts impressive functionality, including multiple cooking modes that allow users to prepare a variety of dishes with ease. Its intuitive interface ensures that even novice cooks can operate it effortlessly.

In contrast, the D7412GV4 offers a balance of capacity and features. It includes a larger cooking area, which is perfect for families or for those who frequently entertain guests. This model is highlighted by its state-of-the-art steam cooking technology, which helps retain nutrients in food while ensuring moist and tender results. Additionally, the D7412GV4 has a built-in self-cleaning feature, making maintenance and upkeep considerably easier for busy homeowners.

Meanwhile, the D9412GV4 showcases Bosch’s commitment to premium quality and performance. This high-end model is designed for the serious home chef, combining powerful heating elements with advanced temperature control for professional-grade results. One of the standout features of the D9412GV4 is its induction cooking technology, which offers rapid heating and precise temperature adjustments, making cooking faster and more efficient. This model is also equipped with smart connectivity, allowing users to control and monitor their cooking process remotely via a dedicated app.

All three models in this series emphasize energy efficiency, with Bosch appliances consistently meeting or exceeding Energy Star standards. They include sleek designs that integrate seamlessly into any kitchen décor, whether contemporary or traditional. Additional features such as safety locks, child-proof settings, and easy-to-clean surfaces enhance their appeal, making them a practical choice for families.

In summary, the Bosch D7212GV4, D7412GV4, and D9412GV4 appliances capture the essence of modern cooking with their blend of compact design, advanced technologies, and user-friendly features. These models represent Bosch's dedication to innovation, performance, and sustainability, making them a wise investment for any home.