The MIC 500 Series camera has a security attachment point for attaching to a safety chain (not supplied), which in turn should be attached to a secure part of the structure during installation or removal.
WARNING!
Use caution when installing the MIC 500 Series camera. Follow common sense precautions such as fitting a safety chain.
1.2 | Safety Earthing of the MIC 500 Series Camera |
|
| ||||||
|
| The electronics and housing of the MIC 500 Series camera are electrically isolated; however, | |||||||
|
| the housing should be safety earthed regardless. This safety earth should be a bonding | |||||||
|
| connection, such as one of the securing bolts, to the outside case of the camera. The camera | |||||||
|
| should be earthed at one point only to prevent earth loops and thus hum bars appearing on | |||||||
|
| the camera picture in the control room. |
|
|
|
| |||
|
| Shielded Composite Cable Connections |
|
|
|
| |||
|
| Note: all connections must be made. |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| Composite Cable Wire Color |
| Function | MIC PSU Terminal Block | PCB Marking |
| ||
|
|
|
|
|
|
|
|
|
|
|
| Red |
|
| AC supply |
| Power |
| |
|
|
|
|
|
|
|
|
|
|
|
| Green |
|
| AC supply return |
| Power |
| |
|
|
|
|
|
|
|
|
|
|
|
| White |
|
| RX + |
| RxB |
| |
|
|
|
|
|
|
|
|
|
|
|
| Yellow |
|
| Rx - |
| RxA |
| |
|
|
|
|
|
|
|
|
|
|
|
| Drain Wire |
|
| Ground |
| GND |
| |
|
|
|
|
|
|
|
|
|
|
|
| Blue |
|
| Tx - |
| TxA |
| |
|
|
|
|
|
|
|
|
|
|
|
| Violet |
|
| Tx + |
| TxB |
| |
|
|
|
|
|
|
|
|
|
|
|
| Coax Core |
|
| Video |
| Video |
| |
|
|
|
|
|
|
|
|
|
|
|
| Coax Screen |
|
| Video return |
| Vid 0V |
| |
|
|
|
|
|
|
|
|
|
|
|
| Black (optional) |
|
| Tamper switch |
| Tamp Sw |
| |
|
|
|
|
|
|
|
|
|
|
|
| Orange (optional) |
|
| Wash drive |
| Wash |
| |
|
|
|
|
|
|
|
|
|
|
|
| Brown |
|
| Heater+ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Gray |
|
|
|
|
|
|
|
|
| 1. Please refer to the MIC Series Power Supply Manual for details on connecting MIC 500 Series cameras with |
| ||||||
|
|
| heaters and other auxiliary equipment. |
|
| ||||
|
|
|
|
|
|
|
|
| |
|
| Mains Power and Video Connections |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| Mains |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Live |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
| Neutral |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
| Earth Connection | Already made |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Video |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Video BNC CN1 | Connection |
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
| Core | Video to Control Room |
|
|
|
| ||
|
|
|
|
|
|
| |||
|
| Screen | Video GND to Control Room |
|
|
| |||
|
|
|
|
|
|
|
|
|
|