OPERATION:
1.Pressing the call button at the door/sub station will activate the call tone, plus light the appropriate station LED at the NEM/NDR master. The call tone will be heard at the
2.To answer the call on the LEF or NEM/NDR master, press the station button corresponding to the lit LED, then press TALK to speak to the visitor. When the first master answers the call, the Occupied lamp will be lit on all other masters. DO NOT answer the call if the Occupied lamp is lit.
3.Communication at the master station is
4.With communication established to the door station, pressing the door release button will activate the door release mechanism at the corresponding door.
5.When the call is completed, press OFF on the LEF master, or the associated black OFF button on the NEM/NDR master. The Occupied lamp will go out on all masters when the call is cancelled.
SPECIFICATIONS: |
|
Power Source: | 12V DC at master. Use |
Communication Output: | 800mW @ 20 ohms(receive); 500mW @ 20 ohms (transmit) |
Communication: | |
| Hands free at sub station. |
Calling: | Master to sub: By voice |
| Sub to master: |
Compatible Remotes: |
|
|
|
Wiring: | 3 conductors from door/sub to |
| 2 common plus 2 individual conductors per door from |
| |
| (Aiphone #822212) |
| 7 conductors from |
| 2 conductors from master to their respective power supply. |
| Shielded cable is recommended. |
Wiring Distance: | 420' with 22AWG; 1,000' with 18AWG. |
Dimensions (H x W x D): | 7" x |
Aiphone Communication Systems |
|
|
1700 130th Ave. N.E. |
|
|
Bellevue, WA 98005 | Toll Free Technical Support: | Page 5 |
(425) | ||
FAX (425) | 0113PH | |
|