3Precautions

This device IS NOT intended for use as a safety sensor.

Shut off all power before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian/vehicle traffic around the area.

Always stop pedestrian/vehicle traffic through the doorway when performing tests that may result in unexpected reactions by the door.

ESD electrostatic discharge: Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your body’s charge.

Always check placement of all wiring before powering up to insure that moving parts will not catch any wires and cause damage to equipment.

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / 19) upon completion of installation.

DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA Inc. Unau- thorized disassembly or repair:

1.May jeopardize personal safety and may expose one to the risk of electrical shock.

2.May adversely affect the safe and reliable performance of the product will result in a voided product warranty.

4 Installation Tips

The sensor must be

firmly fastened toDO NOT cover the sensor. prevent vibration.

The sensor must not have any object likely to move or vibrate in its sensing field.

5 Wiring

 

POWER (VAC / DC)

 

ACTIVATION RELAY

 

 

PRESENCE RELAY

 

LABEL

 

 

 

 

 

 

 

 

 

12-24

12-24

COM

 

NO

NC

COM

NO

NC

 

 

 

 

 

 

 

 

 

 

 

 

COLOR

RED

BLACK

WHITE

 

GREEN

YELLOW

WHITE W/BLACK

GREEN W/BLACK

YELLOW W/BLACK

 

STRIPE

STRIPE

STRIPE

 

 

 

 

 

 

 

6 Installation

1

Sensor Tilt Angle

It is important to adjust sensor angle first to position IR field correctly. Then adapt angle of radar field by using tilt angle adjustment screw.

EI C

 

G

 

N

I

L

30°

 

15°

MOU N

T

6.50

3.25

0

3.25

6.50

20∞

30∞

45∞

ft.

ft.

3.25

NOTE: To obtain an IR pattern that’s

straight down (closest to the

 

 

door thershold); wall mounted

6.50

sensors need to be set at

 

20º, while sensors that are

9.75

extended out from the wall

 

should be set at around 15º.

13.00

 

16.30Mounting height: 16 ft.

Sensitivity: 9

19.70Microwave field angle: 30°

30°

15°

W

 

ALL MOUNT

When the angle of the sensor is chosen, tighten the screws firmly.

Page 2 of 6

75.5371.01 EN 20080505 (75.5370)

Image 2
Contents Specifications DescriptionWiring PrecautionsInstallation Tips InstallationRemote Control Functions Microwave Field Tilt AngleRemote Control Parameters Setup & StartupSetup Sequence Microwave Default Infrared Configuration MicrowaveInfrared Setup Sensitivity MicrowaveTroubleshooting Company Contact

IS40, IS40P specifications

The BEA IS40P and IS40 are advanced infrared safety sensors designed for a variety of applications, particularly in the realm of automatic doors and industrial automation. These sensors exemplify cutting-edge technology and excellent functionality, making them reliable solutions for ensuring safety in both commercial and industrial environments.

One of the standout features of the BEA IS40P and IS40 is their precision in detecting moving objects. They utilize proprietary infrared technology that allows them to sense human presence accurately, enabling them to prevent accidents in high-traffic areas. The sensors have a wide detection range, which is adjustable according to specific needs, ensuring optimal performance in various settings.

The IS40 series is equipped with advanced anti-collision and anti-intrusion features, making them highly effective in detecting potential hazards. This capability significantly enhances workplace safety, especially in environments where machinery operates near personnel. Their seamless integration with automatic doors allows for instant opening and closing, maximizing operational efficiency while maintaining safety.

Another key characteristic of the IS40P and IS40 sensors is their robust construction. Designed to withstand harsh environmental conditions, these sensors are built with durable materials that resist impact and corrosion. This resilience ensures a long operational life, reducing maintenance costs and enhancing overall reliability.

Additionally, the IS40P and IS40 sensors support various installation configurations, including wall mounting and surface mounting. The flexibility in installation options allows for easy integration into existing systems, making them an ideal choice for retrofitting projects. Their sleek and unobtrusive design ensures they blend well with modern architectural styles.

Both the IS40P and IS40 incorporate advanced LED indicators that provide real-time feedback on sensor status and operation. This feature simplifies troubleshooting and maintenance, making it easier for technicians to identify issues promptly. Moreover, these sensors are designed to be energy-efficient, contributing to lower operational costs.

In summary, the BEA IS40P and IS40 infrared safety sensors represent a significant advancement in safety technology. Their combination of precise detection capabilities, robust construction, installation flexibility, and user-friendly features make them an invaluable asset in ensuring safety and efficiency in any environment where automatic doors or machinery are in use. With the IS40 series, BEA continues to set a high standard in safety sensor technology, providing peace of mind in a wide range of applications.