Visit Us on the Web! www.SmokeAlarms.com
MODEL USI-2430
HEAT ALARM
120 VAC WITH
9V BATTERY BACKUP
OWNER'S MANUAL
PLEASE READ AND SAVE!
Installer: Please leave this manual with the product.
WHAT YOU SHOULD KNOW ABOUT HEAT ALARMS
Heat alarms are not life safety devices and are not designed to detect smoke or fire. They are intended to detect temperatures of 135oF to provide an additional source of information that is supplemental to smoke alarms to increase the probability that an early warning will be provided to increase chances of life and property safety.
FEATURES
•This heat alarm is powered by 120 VAC and a 9 Volt battery backup source. AC/ DC heat alarms offer added protection in the event of a power failure or a drained battery.
•This heat alarm can be interconnected with as many as 12 other USI alarms (Models
•This heat alarm will not attach to the mounting ring if a battery is not in the battery chamber.
•This heat alarm will sound a short beep about once a minute if the battery is weak or improperly connected.
•The green LED indicates that the heat alarm is receiving AC power and is working under normal operation.
•A loud 85 decibels at 10 feet alarm horn will sound to alert you of an emergency.
•The test button checks heat alarm operation.
SPECIFICATIONS
Model Number |
|
Electrical Rating | 120 VAC, 60 Hz, 50 mA maximum, 9 Volt |
| battery backup |
Interconnect | 18 units maximum |
|
|
Interconnect with | Up to 5 USI heat alarms or relay modules and |
| up to 12 USI smoke alarm models |
UL Temperature Rating | 135oF (57oC) fixed temperature |
UL Maximum Ambient Temperature | 100oF |
at Unit |
|
Operating Temperature | |
UL Recommended Coverage | 2500 square feet |
UL Recommended Spacing | 50 feet |
Maximum Distance from Wall | 25 feet |