Universal Security Instruments SS-901 manual Avoid These Locations, False Alarms, Installation

Page 3

AVOID THESE LOCATIONS

the garage – products of combustion are present when you start your automobile.

near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, gas hot water heaters). Use smoke alarms with Silence Control for these areas.

in areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 3 feet (0.9 meters) away from these areas.

in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms shall not be located where airflow prevents operation of the alarms.

in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm operation.

in areas where temperature may fall below 400F (4.40C) or rise above 1000F (37.80C).

closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering may affect the alarm's operation.

closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle) fan.

on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall).

THIS SMOKE ALARM WILL NOT OPERATE WITHOUT A BATTERY INSTALLED. PROPER BATTERY MUST BE INSTALLED IMMEDIATELY WHEN LOW BATTERY SIGNAL IS GIVEN OR THE UNIT WILL FAIL. TEST WEEKLY. READ AND FOLLOW ALL INSTRUCTIONS OR UNIT WILL NOT OPERATE PROPERLY.

FALSE ALARMS

The smoke alarm is designed to minimize false alarms. Smoking will not normally set off the alarm unless smoke is blown directly into the smoke alarm. Combustion particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooking surface. Large quantities of combustion particles are generated from spills or broiling.

If the smoke alarm does alarm, check for fires first. If a fire is discovered, get out and call the fire department. If no fire is present, check to see if one of the reasons listed above may have caused the alarm.

INSTALLATION

Your smoke alarm is designed for easy mounting on wall or ceiling. A complete mounting kit is included with the smoke alarm. First, attach the mounting bracket on the wall or ceiling with the screws provided. Second, push and turn the smoke alarm clockwise on the mounting bracket. (Note: Your smoke alarm is equipped with a safety device which prevents mounting unless a battery is installed. If your smoke alarm will not lock into the mounting bracket, check to make sure a battery is installed.)

Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of, the bedrooms) and heat or smoke alarms in living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets, utility storage rooms, basements and attached garages. Test the smoke alarm weekly to assure proper operation.

OPERATION, TESTING & MAINTENANCE

OPERATION: The smoke alarm is operating once the battery is connected. When products of combustion are sensed, the unit sounds a loud alarm which continues until the air is cleared.

This alarm incorporates the internationally recognized horn signal for evacuation. During alarm mode, the horn produces three short beeps followed by a two second pause and then repeats.

STANDBY CONDITION: The red LED flashes once every 40-60 seconds to indicate the unit is properly functioning.

LOCAL ALARM CONDITION: The red LED flashes rapidly and the unit emits a loud, pulsating alarm sound.

TESTING: Test by pushing the test button on the smoke alarm cover until the alarm sounds, then release. The alarm sounds if all electronic circuitry, horn and battery are working. The alarm may continue to sound for up to 10 seconds after the button is released. If no alarm sounds, the unit may have a defective battery or other failure. Test the smoke alarm weekly to assure proper operation.

Page 3

Image 3
Contents Read ALL Instructions Smoke Alarm Limitations and FunctionsRecommended Location of Alarms Avoid These Locations False AlarmsInstallation OPERATION, Testing & MaintenanceRepairs and Services Battery ReplacementBasics of Escape Plan Develop and Practice a Plan of EscapeUniversalfiveyearlimitedwarranty

SS-901 specifications

Universal Security Instruments SS-901 is a versatile and reliable smoke detector that enhances home safety and gives homeowners peace of mind. This model boasts a range of features designed to meet the needs of modern living while maintaining user-friendly operation.

One of the standout features of the SS-901 is its dual sensor technology. It combines ionization and photoelectric sensors, which work together to effectively detect a wide range of fire types. Ionization sensors are highly sensitive to fast-flaming fires, while photoelectric sensors excel at detecting smoldering fires. This dual capability ensures comprehensive protection, significantly reducing the risk of false alarms while enhancing smoke detection accuracy.

The SS-901 is also equipped with a built-in battery backup. This feature ensures that even during power outages, the smoke detector continues to function, providing uninterrupted safety for the household. The unit operates on a long-lasting battery, minimizing the need for frequent replacements and enhancing overall convenience.

Another key characteristic of the Universal Security Instruments SS-901 is its user-friendly design. The unit includes a single test button, allowing homeowners to easily check the functionality of the smoke detector with just a press of a button. An LED indicator informs users of the device's status, including battery life and alarm status, delivering clear communication about the detector’s operation.

Additionally, the SS-901 incorporates a low battery warning signal. This alerts users when the battery is running low, prompting timely replacement to ensure continuous protection. The compact and sleek design of the smoke detector allows for easy installation in various environments, whether on a ceiling or wall, making it suitable for any home setting.

The Universal Security Instruments SS-901 complies with safety standards set by authorities, providing an extra layer of reassurance for users. The combination of advanced technologies, user-friendly features, and reliable operation makes the SS-901 a preferred choice for families looking to enhance their fire safety measures. Investing in this smoke detector is a proactive step towards creating a safer living environment, underlining the importance of fire safety in every household.