SECO-LARM USA SK-1123-SQ warranty Wiring, Tamper N.C, Duress Output, Door Sensing

Page 6

Digital Access Keypad Manual

WIRING:

Example Wiring, with Inhibit Control Authorized

CONNECTIONING INHIBIT

AUTHORIZATION CONTROL

WARNING

 

 

 

Tamper

N.C.

 

 

 

Interlock

 

For safety, ensure that no

 

 

 

 

 

one is inside the premises

 

O/P 1

Inhibit

before starting the door

 

 

Door

Sensor

lock inhibit function.

 

 

 

 

(--)

Ground

During inhibit, doors

 

 

 

 

Duress

Output

remain locked.

 

 

 

 

Keypad

Active

 

 

 

 

(+)

(--)

Output #1

Output #2

Egress

12-24V

AC/DC N.C.

COM N.O.

N.C. COM N.O.

In

 

Digital Access Keypad Manual

WIRING:

Auxiliary Accessories

TAMPER N.C.

Tamper

ALARM

N.C.

CONTROL

 

PANEL

 

24-hour N.C.

 

protection

 

zone

DURESS OUTPUT

Duress

(-)

ALARM

Output

Ground

CONTROL

 

 

 

 

PANEL

 

 

24-hour N.O.

 

 

protection zone,

 

 

max. 100mA

12~24V

+

AC/DC

 

power

 

supply

 

--

ST-UV12-S1.0Q

N.C. N.O.

OR

Output Relay N.O. Output for Fail-secure lock N.C. Output for Fail-safe lock

DOOR SENSING

Door

(-)

 

Required for:

Sensing

Ground

MAGNETIC

 

 

 

DOOR

• Door Auto Relock

 

 

CONTACT

• Door Forced-open Alarm

 

 

(N.C.)

 

 

• Door Propped-open Alarm

 

 

 

 

 

SM-200

• Mantrap (Interlock) Control

 

 

 

 

 

 

Electric

Egress button

 

--------

--Lock +

N.O.

 

(Inside premises)

 

 

--------

Additional egress

 

 

------------

Note: If inhibit control is activated, the duress output is disabled.

KEY ACTIVE or ALARM OUTPUT

The Key Active Output will switch to ground (-) for 10 seconds whenever a key is

buttons can be

N.O.

1N4004 Cathode

connected in parallel ----------------

 

 

 

+12V

Keypad

 

Keypad

Active

 

Active

 

1.5k

Low

 

power

 

 

+12V

N.O. relay contact

touched. Use to turn ON an LED and/or a small buzzer to notify a guard, or to energize a relay to switch ON lights or CCTV camera.

• Connect a 1N4004 diode as close as possible to and in parallel with the DC-powered electromagnetic or electric lock.

This absorbs possible electromagnetic interference to prevent operation of the lock from damaging the keypad. A

1N4004 is not required for AC-powered locks.

• Connect the ground (-) terminal of the keypad to earth to prevent electrostatic discharge from damaging the keypad.

• The connection of relay output #1 disable to output #2, as shown above is optional. When so wired, output #2 is the

inhibit control. To use, program output #2 for shunt on/off operation. When output #2 is ON, relay output #1 will not

work. For example, this can be used to prevent users from entering the protected premises during the evening or

LED

piezo

buzzer

OR

Isolation

relay

Only one connection option is recommended. Make sure the current sink does not exceed the maximum rating of 100mA.

An external power supply and isolation relay are necessary to drive high power devices such as lights or CCTV cameras.

weekend. See programming option 61.

RELAY OUTPUT #2 -- Example, to shunt an alarm N.C. zone

• The green LED lights while relay output #1 is activated to activate the lock.

The red LED lights to show that relay output #1 is disabled by the activation of output #2.

Tape all unused wires to prevent short circuits.

WARNING:

If the inhibit control is used, all personnel must exit the protected premises before output #2 is activated. Otherwise, personnel in the protected premises will not be able to exit until output #2 is turned OFF.

The user code for output #2 in this case should be given only to personnel authorized to enter the premises any time. It should not be given to other users.

N.C.COM N.O.

Output #2

N.C.

N.C. magnetic contact

SM-200

To protection zone of an alarm control panel

Use Normally Open (N.O.) output remove to shunt a Normally Closed (N.C.) protection zone of an alarm system.

Set relay output #2 to Start / Stop mode (programming option 51)

Page 6

SECO-LARM U.S.A., Inc.

Page 11

Image 6
Contents Millikan Avenue, Irvine, CA FaxUser Operation for the SK-1123-SQ Tel 800-662-0800Parts List Table of ContentsDimensions IntroductionInstaller Programming Unique FeaturesAuto or manual code entry checking Preparing to Program the Keypad WIRING, Basic DiagramEnter the * key again to exit programming mode Getting StartedSpecifications Programming NotesTamper N.C WiringKEY Active or Alarm Output Duress OutputDoor #1 Door #2User Name Access Code User NameUser ID

SK-1123-SQ specifications

The SECO-LARM USA SK-1123-SQ is a versatile and reliable access control solution designed for various security applications. This compact and user-friendly device is widely used in residential and commercial settings due to its robust features, advanced technology, and ease of installation.

One of the standout characteristics of the SK-1123-SQ is its weather-resistant design, making it suitable for outdoor use. Equipped with a sturdy construction, it can effectively withstand various environmental conditions, ensuring consistent performance regardless of the weather. This makes it an ideal choice for securing entries, gates, and perimeters in diverse locations.

The device operates using a highly efficient electromagnetic locking system that provides a secure and controlled entry point. Designed for quick and reliable locking and unlocking, it supports both card and fob access methods, giving users flexibility in managing who can enter a designated area. This feature makes it compatible with various RFID standards, enabling seamless integration into existing security systems.

The SK-1123-SQ is equipped with an intuitive user interface that simplifies programming and operation. The device supports multiple access key fobs, allowing for managing different user levels efficiently. Furthermore, it features a built-in panic button, which can quickly unlock the door in case of emergencies, enhancing security and safety for all occupants.

In terms of installation, SECO-LARM has made significant strides in simplifying the process of setting up the SK-1123-SQ. With clear instructions and compatible mounting options, it can be installed in minimal time, making it an excellent choice for both professional installers and DIY enthusiasts.

Additionally, the SK-1123-SQ's compact design allows it to fit in tight spaces without sacrificing functionality, adding to its appeal in various installations. Its reliability is further backed by SECO-LARM's reputation for producing high-quality security products.

In summary, the SECO-LARM USA SK-1123-SQ stands out as a leading access control solution due to its weather-resistant design, various access methods, user-friendly functionalities, and hassle-free installation. With its advanced locking technology and commitment to safety, it represents an excellent investment for anyone looking to enhance their security measures.