NETGEAR AGM732F manual SFP timing parameters for SFP management, Txdisable, Txfault

Page 8

AGM732F

SFP timing parameters for SFP management

Parameter

 

Symbol

Min.

Max.

Unit

 

 

Unit Conditions

 

TX_DISABLE Assert

 

 

 

 

Time

from

rising edge

of TX_DISABLE

to

t_off

 

10

µsec

when

the

optical output falls below 10%

of

time

 

 

 

 

 

 

 

 

 

 

 

nominal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX_DISABLE

 

 

 

 

 

Time

from

falling edge

of TX_DISABLE

to

 

t_on

 

1

msec

when

the

modulated

optical output rises

Negate time

 

 

 

 

 

 

 

above 90% of nominal

 

 

 

 

 

 

 

 

 

 

 

 

Time

to

initialize,

 

 

 

 

From power on or negation of TX_Fault using

including

reset

of

t_init

 

300

msec

 

TX Disable.

 

 

TX_FAULT

 

 

 

 

 

 

 

 

 

 

 

TX

Fault

Assert

t_fault

 

100

µsec

Time from fault to TX fault on.

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX_DISABLE

to

t_rest

10

 

µsec

Time TX Disable must be held high to reset

reset

 

 

 

 

 

 

 

TX_Fault

 

 

 

LOS Assert Time

 

t_loss_on

 

100

µsec

Time from LOS state to Rx LOS assert

 

LOS Deassert Time

t_loss_off

 

100

µsec

Time from non-LOS state to Rx LOS deassert

Serial ID Clock Rate

f_serial_clock

 

100

kHz

 

 

 

 

 

7

Rev. 0A

Image 8
Contents AGM732F Performance DescriptionApplications Electrical Characteristics Absolute Maximum RatingsRecommended Operating Conditions TjrxOptical Characteristics Mask of the eye diagram for the optical transmit signalTjtx RINPlug Seq. Pin engagement sequence during hot plugging Rev a Open Package Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management TxdisableTxfault SFP timing parameters AGM732F Eeprom Serial ID Memory Contents 2-Wire Address A0h Regulatory Compliance EMIAGM732F-0