AGM732F
SFP timing parameters for SFP management
Parameter |
| Symbol | Min. | Max. | Unit |
|
| Unit Conditions |
| |||
TX_DISABLE Assert |
|
|
|
| Time | from | rising edge | of TX_DISABLE | to | |||
t_off |
| 10 | µsec | when | the | optical output falls below 10% | of | |||||
time |
|
|
|
| ||||||||
|
|
|
|
|
|
| nominal |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
TX_DISABLE |
|
|
|
|
| Time | from | falling edge | of TX_DISABLE | to | ||
| t_on |
| 1 | msec | when | the | modulated | optical output rises | ||||
Negate time |
|
| ||||||||||
|
|
|
|
| above 90% of nominal |
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
Time | to | initialize, |
|
|
|
| From power on or negation of TX_Fault using | |||||
including | reset | of | t_init |
| 300 | msec | ||||||
| TX Disable. |
|
| |||||||||
TX_FAULT |
|
|
|
|
|
|
|
|
|
|
| |
TX | Fault | Assert | t_fault |
| 100 | µsec | Time from fault to TX fault on. |
| ||||
Time |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |
TX_DISABLE | to | t_rest | 10 |
| µsec | Time TX Disable must be held high to reset | ||||||
reset |
|
|
|
|
|
|
| TX_Fault |
|
|
| |
LOS Assert Time |
| t_loss_on |
| 100 | µsec | Time from LOS state to Rx LOS assert |
| |||||
LOS Deassert Time | t_loss_off |
| 100 | µsec | Time from | |||||||
Serial ID Clock Rate | f_serial_clock |
| 100 | kHz |
|
|
|
|
|
7
Rev. 0A