Bosch Appliances 28CDI, 35CDI II, 24CDI Clearances, Room Thermostat, Thermostatic Radiator Valves

Page 6

CLEARANCES

 

24,28CDi RSF

35CDi II

24CDi OF

24CDiBF

 

 

 

 

 

Left-hand side

10

10

10

10

Right-hand side

10

10

10

10

In Front

600

600

600

600

Above

180

180

300

100

Below

200

200

200

200

 

 

 

 

 

Minimum clearances in millimetres.

Your installer will have provided adequate space around the appliance for safety and servicing. Do not restrict this space by the addition of cupboards, shelves etc. close to the appliance.

ROOM THERMOSTAT

A room thermostat may be fitted for control of the central heat- ing temperature. It will be located in one room of the home. The method of setting a room thermostat varies with the type and manu- facture. Refer to the instructions supplied with the room thermostat.

THERMOSTATIC RADIATOR VALVES

If thermostatic radiator valves are fitted to the system then they must conform to the requirements of BS2767. The radiator located in the room where the room thermostat is sited must be controlled by a thermostatic radiator valve.

SHOWERS, BIDETS, TAPS AND MIXING

VALVES

Standard hot and cold taps and mixing valves used with the appliance must be suitable for operating at mains pressure. Thermostatically controlled shower valves will guard against the flow of water at too high a temperature.

If using a pressure equalising valve, set the Domestic Hot Water temperature control knob to the ‘MAX’ position.

Hot and cold mains fed water can be supplied direct to an over- rim flushing bidet subject to local water company requirements.

With all mains fed systems the flow of water from the individ- ual taps will vary with the number of outlets operated simultaneous- ly and the cold water mains supply pressure to the property. Flow bal- ancing using ‘Ball-o-Fix’ type valves is recommended to avoid an excessive reduction in flow to individual outlets.

For further information contact The Worcester Technical Helpline. 08705 266241

HOT AND COLD FLOW

The flow of water demanded from both hot and cold service out- lets is dependent upon mains supply, it may not be possible in some installations to operate all outlets simultaneously.

WATER MAINS FAILURE

It is important to note that in the event of a mains water supply failure, no tap water will be available until the mains supply is restored. The appliance can still be used for heating provided that the system is of the sealed system type. Open vent central heating sys- tems should be turned off until the supply is restored.

USE IN HARD WATER AREAS

 

Normally there is no need for scale protection. However, in areas

 

of exceptionally hard water supply it is recommended that an In-Line

 

scale inhibitor be fitted.

 

Installation should be strictly in accordance with the require-

 

ments of the local Water Company. An isolating valve to facilitate

6

servicing should be incorporated.

 

Image 6
Contents Combi Contents Excellence Comes AS StandardBenchmark GAS Safety Installation and USE RegulationsGeneral Information General DescriptionHot Water Mode General Notes Central Heating SystemSealed Heating System Thermostatic Radiator Valves ClearancesRoom Thermostat SHOWERS, BIDETS, Taps and Mixing ValvesCleaning Frost PrecautionsService AIR Supply for Open Flued O.F. AppliancesOperation Controls Indicator Lights To Light and Stop Appliance AIR Flow Device RSF only Removal and ReplacementIgnition Lockout Flue Spillage Device of onlyAppliance Fails to Operate CALL-OUT ChargesMaintaining Your Appliance Service Centres Contact NumbersYour Worcester CDi Combi Guarantee Guarantee Registration For Your OWN Record
Related manuals
Manual 16 pages 18.54 Kb

28CDI, 35CDI II, 24CDI specifications

Bosch Appliances has established itself as a leader in the world of heating and hot water solutions, and its range of condensing boilers, specifically the 28CDI, 35CDI II, and 24CDI models, exemplifies their commitment to innovation, efficiency, and reliability.

The Bosch 28CDI condensing boiler is designed with efficiency in mind, delivering a powerful output without compromising on energy consumption. With a maximum output of 28kW, it is ideal for medium-sized homes and offers high levels of heating performance. Its compact design makes it easy to install in various locations, even in smaller homes. Notably, the 28CDI features a built-in wireless connectivity option, allowing users to monitor and control their heating system remotely via a smartphone app.

The Bosch 35CDI II takes energy efficiency to the next level, with an increased output of 35kW, providing ample heating for larger homes. This model incorporates advanced weather compensation technology, which adjusts the heating output based on outdoor temperature, thus optimizing energy use and enhancing comfort. Additionally, the 35CDI II features a high-efficiency stainless steel heat exchanger, ensuring durability while maximizing energy savings. The boiler's intuitive user interface makes it easy to operate, providing users with real-time information about their heating system.

For even smaller spaces, the Bosch 24CDI offers a compact solution with an output of 24kW. This model is particularly effective for energy-conscious homeowners. It includes an integrated condensing technology which allows for efficient heat recovery from exhaust gases, resulting in lower energy bills and reduced carbon emissions. The 24CDI is also designed for quiet operation, ensuring that it runs smoothly without disturbing the household.

All three models boast several advanced safety features, including frost protection, pressure relief, and a quick reset function. They are also compatible with Bosch's range of smart controls, enabling users to tailor their heating needs according to their schedule and preferences. With these notable characteristics, the Bosch 28CDI, 35CDI II, and 24CDI boilers provide efficient, reliable heating solutions tailored to various household requirements, ensuring comfort and peace of mind for homeowners.