Table of Contents
Introduction | 1 | |
Features & Benefits | 1 | |
Precautions | 2 | |
1. | Intended Application | 2 |
2. | Registration | 2 |
3. | Specifications | 2 |
4. | Installation | 2 |
| 4.1 Location | 2 |
| 4.1A In Humid Area, No Ducting | 3 |
| 4.1B In Humid Area, Duct Inlet and/or Outlet | 3 |
| 4.1C In Remote Area, Duct Inlet & Outlet | 3 |
| 4.1D In Remote Area, Duct Outlet Only | 4 |
| 4.1E In Remote Area, Duct Inlet Only | 4 |
| 4.2 Remote Humidity Control | 4 |
| 4.3 Electrical Requirements | 5 |
| 4.4 Condensate (Water) Removal | 5 |
| 4.5 Drainage and Trap | 5 |
5. | Ducting | 5 |
| 5.1 Optional Ducting Kit | 5 |
| 5.2 Ducting for Dehumidification | 5 |
6. | Operation | 5 |
| 6.1 Humidity Control Adjustment | 5 |
| 6.2 Blower (Fan) Switch | 6 |
7. Maintenance | 6 | |
| 7.1 Air Filter | 6 |
| 7.2 Blower Oiling | 6 |
8. | Service | 6 |
| 8.1 Technical description | 6 |
| 8.2 Troubleshooting | 6 |
| 8.3 Defrost Thermostat | 7 |
9. | Service Parts List | 7 |
10. Accessory/Replacement Parts List | 7 | |
11. Wiring Diagram | 7 |
Read the installation, operation and maintenance instructions carefully before installing and using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Santa Fe HC dehumidifier.
READ AND SAVE THESE INSTRUCTIONS
WARNING
The Santa Fe HC is designed to be installed indoors only.
1 Intended Application for Santa Fe HC
For the ideal installation, draw air from the central part of the home and return it to isolated areas of the home like the bedrooms, den, utility room, or family room. The ductwork of the existing forced air system can be used to supply air to the home.
2 Registrations
The Santa Fe HC conforms to UL STD 1995.
3 Specifications
Model: | Santa Fe HC (P/N 4025081) | |
Electrical: | ||
Capacity: | 135 pints/day @ 80°F, 60% RH | |
Operating Temp: 55°F min., 100°F max. | ||
Air Flow: | 355 CFM without external ducting | |
| 335 CFM @ .20 IWG external static | |
| 315 CFM @ .40 IWG external static | |
Refrigerant Charge: | 1 lb., 12 oz. R22 | |
Duct Connections: | Round 10" inlet, 10" outlet | |
Filter Size: |
| 2" X 16" X 20" |
Unit Size: | 33"L x 21"W x 18.65"H | |
Shipping Size: | 39”L x 25”W x 28.5”H | |
Unit Weight: | 100 lb. |
|
Shipping Weight:138 lb.
4 Installation
4.1 Location
The Santa Fe HC can be installed in a variety of
locations to meet the owner's needs; other considerations include:
1)Providing access to a 115 VAC power outlet (7’ power cord is provided).
2)Locating near a floor or other suitable drain (4’ drain hose included).
3)Do not install the Santa Fe HC with the exhaust of the unit within 1’ of a wall or obstruction. Do not place the unit near open water.
1’ Minimum
Figure 3: Installation requires a minimum 1’ exhaust clearance.
2 | Santa Fe HC Owners Manual |