H. Install the Log Assembly

Log Assembly: LOGS-6CL

Models: 6000CL-IPI-S, 6000CL-IPILP-S,

6000CL-IPI-T, 6000CL-IPILP-T

FIBER BURNER TOP

LOCATING HOLES

 

 

TAB BENT IN = NG

BURNER SHIELD

PILOT COVER

BURNER ASSEMBLY

 

 

TAB NOT BENT = LP

GUIDE SLEEVES

 

Figure 1

 

LOG PLACEMENT TABS

LOG PLACEMENTINDENTATIONS

Figure 2

GRATE TINE

CAUTION: Logs are fragile, handle with care. Log #1 (SRV2164-701): Locate log placement tabs on the pilot cover. Bend tabs upward as shown in Figure 2. Locate the log placements slots on the bottom of Log # 1 (see Figure 3). Mate the slots located on the bottom of Log #1 with the log placement tabs on the pilot cover. Log # 1 is properly installed when it sits squarely and completely on pilot cover with tabs engaged (see Figure 4).

Figure 3

LOG PLACEMENT SLOTS

LOG PLACEMENT TABS

1

Figure 4

Figure 4 shows the log placement tabs located on the top of Log # 1. The tabs will be mated with the slots located on the bottom of Log #2 and Log #3 (see Figure 5). Log #2 and Log #3 also have grooves that allow the logs to be seated properly on the grate (see Figure 5). Hold Log #1 upright while placing Log #2.

Bottom views of

Logs # 2 and 3

LEFT GRATE TINE

SLOTS

32

GROOVES

Figure 5

2

Figure 6

1

Log #2 (SRV2164-702): Mate the slot located on the bottom of Log #2 with the left log placement tab on top of Log #1. After slot and tab have been fitted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine.

Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T2165-900 Rev. S • 9/12

61

Image 61
Contents HOT Surfaces What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsLimited Lifetime Warranty Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions Limited Lifetime WarrantyListing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceModule Reset IPI Battery Tray/Battery InstallationNine Hour Safety Shutdown Feature Control Module OperationFinal inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianLogs FireboxSide Refractory Removal Refractory, Grate and Valve Assembly RemovalBase Refractory Burner Identification/VerificationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Any such action may cause a fire hazardSelecting Appliance Location Framing and Clearances6000 8000Clearances Constructing the Appliance Chase6000 8000Combustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination Locations= 9 inches U.S.A Covered Alcove ApplicationsApproved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsOne Elbow Vent Diagrams Top Vent Horizontal TerminationVent pipe, if desired 6000CL-IPI 8000CL-IPI V1 Minimum H1 Maximum6000CL V1 Minimum H1 + H2 Maximum Two Elbows8000CL V1 Minimum H1 + H2 Maximum Min Max Top Vent Horizontal Termination Three ElbowsTOP Refractory RestrictorMaximum + V 2 Min Top Vent Vertical TerminationH1 + H2 V1 + V2 Minimum H1 + H2 Maximum Top Vent Vertical Termination Three ElbowsPage H1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination Two Elbows8000CL 6000CL H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 MaxV1 Minimum H1 Maximum Rear Vent Vertical Termination One ElbowMinimum + H Maximum V1 Minimum H1 + H2 + H3 Maximum 10 ft Rear Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Install the Ceiling FirestopInstalling the Optional Heat-ZoneGas Kit Install Attic Insulation ShieldFlat Ceiling Installation Vaulted Ceiling InstallationTop Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear VentSecuring and Leveling the Appliance Installing the Non-combustible BoardHeader Attach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingRoof Pitch Min. Ft Install Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination DVP-HPC1 DVP-HPC2 Install Horizontal Termination Cap DVP and SLP PipeFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire PlusTM Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationWall Switch Installation for Fan Optional Electrical Service and Repair Junction Box InstallationFacing Material FinishingFinishing Material Inch Thick or Less DoorsDoor FIT Finish Material See Thickness Models Finishing Material Thickness Inches maximumFinishing Strips Removed Removal of Finishing StripsKenwood Mantel W/ Base Afkdmpc W/ Htkdmpc Elevated Hearth SystemsAppliance Setup Back Refractory Panel Installation Refractory InstallationRight Refractory Panel Installation Ember Placement Left Refractory InstallationTop Refractory Installation No GapsModels 6000CL-IPI-S, 6000CL-IPILP-S Install the Log Assembly6000CL-IPI-T, 6000CL-IPILP-T Bottom views Logs # 2LOG Contacts Grate Tines 8000CL-IPI-T, 8000CL-IPILP-T Models 8000CL-IPI-S, 8000CL-IPILP-SBottom view Logs # 2 Horizontal Grate BAR Air Shutter Setting Install Trim and/or SurroundAir Shutter Settings 6000 Fully Open 8000Symptom Possible Cause Corrective Action TroubleshootingIntelliFire PlusTM Ignition System Troubleshooting Reference Materials Appliance Dimension DiagramLocation Inches Millimeters GAS Line Access R Left Side TOP View Front View Right View DVP-AS2 Vent Components DiagramsHorizontal Termination Cap DVP-TRAPBEK DVP-BEK2 RF6M RF12MDVP-TRAPFL COOL-ADDMDVP-FBHT DVP-TVHWDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Optional Wire HarnessPVI-SLP SLP-LPCSLP90 SLP45SLP Pipe DVP-SLP24SLP-WT-BK SLP-TRAPDVP-2SL SLK-SNKD SLP-CCS-BKSLP-DCF-BK SLP-TVHW6000CL-IPI-T, 6000CL-IPI-S Log Set Assembly Service PartsStocked At Depot8000CL-IPI-T, 8000CL-IPI-S Log Set Assembly6000CL-IPI, 8000CL-IPI TUP-GBK-12 Contact Information

6000CL-IPI-T, 6000CL-IPI-S, 8000CL-IPI-S, 8000CL-IPI-T specifications

Heat & Glo has recognized the importance of creating both aesthetic and functional gas fireplaces that cater to the diverse needs of modern homeowners. Among their impressive lineup, the LifeStyle series stands out, particularly the models 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S, and 8000CL-IPI-T. Each of these units is designed to deliver exceptional performance, energy efficiency, and versatility.

The LifeStyle 6000CL-IPI-S and 6000CL-IPI-T models are distinguished by their contemporary linear design, offering a sleek aesthetic that perfectly complements modern interiors. Whether you choose the linear version with a sleek front or opt for one with traditional styling, both models provide flexibility in installation, making them suitable for various settings. The 8000CL-IPI series takes this further, offering larger fire viewing areas, which enhances the ambiance of any living space.

A notable feature across these models is the IntelliFire® automated ignition system, which provides reliable and efficient operation. This technology ensures that users can light their fireplaces with ease, eliminating the hassle of manual ignition. Additionally, the systems can be controlled via a remote, giving homeowners the convenience of adjusting flame height, heat output, and other features from a distance.

The fireplaces are designed with an emphasis on energy efficiency, making them an environmentally friendly choice. The advanced burner systems not only produce beautiful flames but also optimize fuel consumption. This means that homeowners can enjoy the warmth and beauty of a fire without the worry of excessive energy bills.

Another significant characteristic of the LifeStyle series is the array of finish options and media choices available. Whether you prefer traditional logs, contemporary glass media, or stone options, there is a choice to suit every style. The customizable nature of these fireplaces allows homeowners to create a focal point that reflects their personal taste.

Additionally, the easy maintenance of these models is a major selling point. With features like the clean-face design, users can spend more time enjoying their fireplaces rather than worrying about upkeep. The seamless cleanouts and accessibility ensure that servicing remains simple and straightforward.

Overall, the Heat & Glo LifeStyle 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S, and 8000CL-IPI-T gas fireplaces embody a perfect blend of innovation, efficiency, and style, making them a preferred choice for those looking to enhance their living spaces with the warmth of a fireplace.