White Rodgers Wiring Diagrams and Configuration Guides for 1F95-1291 Thermostat

Page 3

WIRING DIAGRAMS

Figure 2 – Single Stage or Multi-Stage System

(No Heat Pump) with Single Transformer

System

RC

RH

C

Y

Y2

W/E

W2

G

O/B

6

L

 

 

 

 

 

 

 

 

 

 

 

 

Single Stage 1

 

 

 

Call for cool

No Output

Call for heat

No output

 

Installer

 

 

(SS1)

 

 

 

 

 

 

 

 

Configuration

 

Fault or System

 

 

 

24 volt

 

 

 

 

 

Menu selects

 

 

 

 

 

 

 

 

 

 

Malfunction

 

 

 

 

 

 

 

 

“O” or “B” for

 

 

 

 

common

 

 

 

 

Blower/Circulator fan

 

Indicator for

 

 

 

 

 

 

 

changeover

Power closed

 

24 volt

24 volt

(optional

 

 

 

 

energized on a call

Heat Pumps

 

for system

 

 

 

 

for cool or Fan On

function. Set

connection for

with “L” terminal

 

power for

power for

 

 

 

 

to “O” terminal

SPDT 3-wire

 

cooling

heating

operation,

 

 

 

 

(also energized in

energized in Cool

connection.

Multi Stage 2

required

Cool mode-1st

Cool mode-2nd

Heat mode-1st

Heat mode-2nd

heating if configured

zone valve

Original production

 

 

& Off mode. Set

 

 

for remote

for Electric Heat)

 

1F95-1291’s

(MS2)

 

 

stage

stage

stage

stage

to “B” terminal

 

 

 

sensor)

 

 

do not have this

 

 

 

 

 

 

 

 

energized in

 

 

 

 

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

Heat & mergency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24VAC

 

 

 

 

 

 

 

 

 

 

 

 

120VAC

 

 

HOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Stage and Multi-Stage Connections

SINGLE STAGE (SS 1) gas, oil or electric.

 

 

 

 

 

 

CLASS II

Refer to equipment manufacturers’ instructions for specific system

MULTI-STAGE (MS 2) gas, oil or electric.

TRANSFORMER

wiring information.

 

 

 

 

 

 

 

 

 

 

 

 

 

This thermostat is designed to operate a single-transformer or two-

After wiring, see INSTALLER CONFIGURATION section for proper

transformer system.

thermostat configuration.

 

 

 

 

 

 

You can configure the thermostat for use with the following fossil fuel systems:

Figure 3 – Heat Pump Systems

System

RC

RH

C

Y

Y2

*W/E

*W2

G

O

6

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat mode-2nd

Heat mode-3rd

 

 

 

 

 

 

 

 

 

 

stage, Emergency

stage, Emergency

 

 

 

 

Heat

 

 

 

 

 

Mode-1st stage

Mode-2nd stage

 

 

 

 

 

 

 

 

 

*Note: Dual Fuel

*Note: Dual Fuel

 

 

 

 

Pump 1

 

 

 

 

No Output

 

 

 

 

 

 

 

 

option de-

option de-

 

 

 

 

(HP1)

 

 

 

 

 

Installer

 

 

 

 

 

 

 

energizes Heat

energizes Heat

 

 

 

 

 

 

 

 

 

mode stage 1

mode stage 1

 

Configuration

 

Fault or System

 

 

 

24 volt

 

 

(compressor)

(compressor)

 

Menu selects

 

 

 

 

 

 

 

 

Malfunction

 

 

 

 

 

when auxiliary

when auxiliary

 

“O” or “B” for

 

 

 

 

common

 

 

Blower/Circulator fan

 

Indicator for

 

 

 

Heat mode-1st

 

heat is energized

heat is energized

changeover

Power closed

 

24 volt

24 volt

(optional

stage,

 

 

 

energized on a call

function. Set

connection for

Heat Pumps

 

for system

 

 

 

for cool or Fan On

with “L” terminal

 

power for

power for

Cool mode-1st

 

 

 

to “O” terminal

SPDT 3-wire

 

operation,

 

Heat mode-3rd

Heat mode-4th

(also energized in

connection.

 

cooling

heating

stage,

 

energized in Cool

 

required

 

heating if configured

zone valve

Original production

 

 

 

(Compressor)

 

stage, Emergency

stage, Emergency

& Off mode. Set

 

 

 

 

for remote

 

 

Mode-1st stage

Mode-2nd stage

for Electric Heat)

to “B” terminal

 

1F95-1291’s

 

 

 

sensor)

 

 

 

 

do not have this

Heat

 

 

 

Heat mode-2nd

 

 

 

energized in

 

 

 

 

 

*Note: Dual Fuel

*Note: Dual Fuel

 

 

connection

 

 

 

 

 

Heat & mergency

 

Pump 2

 

 

 

 

stage,

 

 

 

 

 

 

 

option de-

option de-

 

mode

 

 

(HP2)

 

 

 

 

Cool mode-2nd

 

 

 

 

 

 

 

energizes Heat

energizes Heat

 

 

 

 

 

 

 

 

 

stage,

 

 

 

 

 

 

 

 

 

mode stages 1

mode stages 1

 

 

 

 

 

 

 

 

 

(Compressor)

 

 

 

 

 

 

 

 

 

and 2 (both

and 2 (both

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compressors)

compressors)

 

 

 

 

 

 

 

 

 

 

when auxiliary

when auxiliary

 

 

 

 

 

 

 

 

 

 

heat is energized

heat is energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

120VAC

120VAC

 

24VAC

 

 

 

 

HEATING

HOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS II

 

 

TRANSFORMER

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

24VAC

 

 

 

 

 

 

 

 

 

 

120VAC

HOT

 

 

 

 

 

 

 

 

 

 

COOLING

 

 

 

 

*Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize.

 

 

 

 

 

 

 

 

 

 

 

 

CLASS II

 

TRANSFORMER

Heat Pump Connections

If you do not have a heat pump system, refer to figures 3 & 4. Refer to equipment manufacturers’ instructions for specific system wiring information.

You can configure the thermostat for use with the following heat pump systems.

HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup.

HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two compressor system with gas or electric backup.

After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration.

3

Image 3
Contents Specifications ApplicationsSave these instructions for future use Power Stealing Switches InstallationInstalling New Thermostat Battery LocationWiring Diagrams Single Stage and Multi-Stage ConnectionsHeat Pump Connections Humidity and Sensors Programming and Configuration Items Hold modeThermostat Quick Reference Home Screen DescriptionKey INSTALLER/CONFIGURATION MenuHeat Cool Mode Fast rateRecord the number you select for future use INSTALLER/CONFIGURATION Menu Fan Operation Emergency ModeOperating Your Thermostat Check Thermostat OperationManual Operation Bypassing the Program Programmable Mode Choose the Fan Setting Auto or On or ProgChoose the System Setting Cool, Off, Heat, Em, Auto Manual Operation for Non-Programmable ModeProgramming Cooling Example Programmable Fan OptionEnergy Saving Factory Pre-Program Planning Your Program ImportantCooling Wake Up Leave For Work Return Home Go To Bed Worksheet for Re-Programming 5+1+1 and 7 Day ProgramHeating Wake Up Leave For Work Return Home Go To Bed Morning Fan Day Evening NightBlower Balance Point for Heating Wired Remote Temperature SensingAveraging or Weighting Remote Sensors Dual Fuel Temperature SetpointTroubleshooting Reset OperationSymptom Possible Cause Corrective Action