White Rodgers 1F94-80 installation instructions Check Thermostat Operation, Troubleshooting

Page 7

CHECK THERMOSTAT OPERATION

EMERGENCY MODE OPERATION

FAN OPERATION

1.Turn on power to the system. If the auxiliary heat source has a standing pilot, be sure to light it.

2.

Press

FAN

until FAN ON is displayed. The blower

SWITCH

 

should begin to operate.

3.

Press

FAN

until FAN AUTO is displayed. The

SWITCH

blower should stop operating within approximately one minute.

HEATING SYSTEM

1. Press

SYSTEM

until HEAT is displayed (it may al-

SWITCH

ready be displayed).

2.Press to adjust thermostat to 99°F. All stages of the heating system should begin to operate within approximately five minutes. However, if the PUMP LED is flashing, the compressor lockout feature is operating (see Lockout Bypass Option to tempo- rarily override the compressor lockout feature during testing).

1. Press

SYSTEM

until EMER is displayed. The red

SWITCH

EMER LED should be lit continuously (non-flashing), regardless of system cycling.

2.Press to adjust thermostat about 5°F above room temperature. Any systems (such as electric strip heaters, fossil fuel systems, etc.) that are wired or jumpered to the emergency circuit (thermostat terminal E1) should begin to cycle.

After the system has been checked and is running prop- erly, determine if automatic changeover is desired (see

SYSTEM CONFIGURATION).

Refer to the OPERATION GUIDE if you need additional information on thermostat operation.

TROUBLESHOOTING

Refer to the Question & Answer section of the OPERA- TION GUIDE for information on troubleshooting the ther- mostat.

COOLING SYSTEM

!CAUTION

To prevent compressor and/or property damage, if power to the compressor has been off or interrupted for more than 1 hour and the outdoor temperature is below 50°F, DO NOT operate the system for at least the amount of time the com- pressor was off! This will allow the compressor heaters to warm the compressor oils to avoid damage due to slugging.

1. Press

SYSTEM

until COOL is displayed.

SWITCH

2.Press to adjust thermostat to 40°F. All stages of the cooling system should begin to operate within approximately five minutes. However, if the PUMP LED is flashing, the compressor lockout feature is operating (see Lockout Bypass Option to tempo- rarily override the compressor lockout feature during testing).

LOCKOUT BYPASS OPTION

FOR QUALIFIED SERVICE TECHNICIANS’ USE ONLY. OPERATORS SHOULD NOT USE THIS FEATURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMAGE, OR PERSONAL INJURY.

COMPRESSOR SHORT TERM

CYCLE PROTECTION

This thermostat has a built-in short term (5-minute) time delay. During this 5-minute period, the thermo- stat will lock out the compressor to allow head pres- sure to stabilize. If you want to override this feature

while testing thermostat operation, simply press PRGMVIEW and TEMPVIEW buttons at the same time at initial startup.

DO NOT USE THE LOCKOUT BYPASS OPTION UNLESS THE COMPRESSOR OIL HEATERS HAVE BEEN OPERATIONAL FOR 6 HOURS AND THE SYSTEM HAS NOT BEEN OPERATIONAL FOR AT LEAST 5 MINUTES.

7

Image 7
Contents Contents PrecautionsDescription Select Thermostat Location SpecificationsInstallation NEW Installation Route Wires to LocationRemove OLD Thermostat Replacement InstallationAttach Subbase to Wall Subbase Power is off with a voltmeterCUT Tape OFF Attach Thermostat to Subbase Reversing Valve Delay OptionCheck Thermostat Operation TroubleshootingWarranty Information for Consumers Warranty Information

1F94-80 specifications

The White Rodgers 1F94-80 is an advanced thermostat designed to enhance home comfort and energy efficiency. This model stands out in the realm of smart thermostats due to its comprehensive features that cater to modern heating and cooling needs.

One of the hallmark characteristics of the 1F94-80 is its user-friendly interface. The device is equipped with a large, backlit touchscreen display that enables easy navigation through various settings, even in low-light conditions. This intuitive design makes it accessible to users of all ages, allowing for straightforward temperature adjustments and programming.

A key feature is its five+two-day scheduling capability, allowing homeowners to set different heating and cooling programs for weekdays and weekends. This flexibility optimizes energy usage by aligning temperature changes with the household's daily routine, making it both cost-effective and environmentally friendly.

The White Rodgers 1F94-80 also incorporates advanced technology, such as Adaptive Intelligent Recovery, which learns how long it takes to heat or cool a space. This feature ensures that the desired temperature is reached by the scheduled time, preventing energy waste. Additionally, the thermostat uses Smart Diagnostic capabilities, providing troubleshooting information and alerts, thus making maintenance hassle-free.

For those keen on home automation, the 1F94-80 is compatible with various smart home systems. This allows users to integrate their thermostat with other smart devices, enabling remote control via mobile apps, voice commands, or automation setups. This level of connectivity enhances user convenience and control over their home environment.

Another noteworthy characteristic is its energy-saving modes. The thermostat offers a range of features aimed at reducing energy consumption, including a 'Hold' feature to temporarily adjust settings without resetting the entire schedule. This makes it easy for users to adapt to unexpected changes or special occasions without compromising their energy efficiency goals.

Safety and reliability are also key elements of the White Rodgers 1F94-80. The device is built with a robust design and includes features such as a filter change reminder, ensuring that heating and cooling systems operate at peak efficiency.

In summary, the White Rodgers 1F94-80 thermostat combines user-friendly technology, advanced scheduling, smart diagnostic features, and energy-saving modes. It represents a significant step in home climate control and efficiency, making it a strong choice for homeowners seeking reliability and comfort.